GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (7)
  • Pyralidae  (2)
  • Aldosterone
  • 1990-1994  (10)
  • 1
    ISSN: 1432-1440
    Keywords: Adenoma ; Aldosterone ; Adrenalectomy ; Gynecomastia ; Hyperaldosteronism ; Hyperplasia ; Spironolactone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Since 1974 primary aldosteronism has been diagnosed in 71 patients in our outpatient clinic. Thirty-four patients had a unilateral aldosterone-producing adenoma, whereas bilateral adrenal hyperplasia was diagnosed in 37 patients. Although at the time of diagnosis the mean potassium values were lower and mean aldosterone levels were higher in patients with an adenoma, as compared to those with bilateral hyperplasia, these laboratory data did not allow us to differentiate between the two leading causes of primary aldosteronism in the individual patient due to pronounced overlap of laboratory values between the two groups. During the first few years, a successful differential diagnosis was made by adrenal phlebography and separate sampling of plasma aldosterone in both adrenal veins; later non-invasive imaging techniques such as computed tomography and radionuclide scanning were used. The best results were obtained in patients with adenoma who underwent adrenalectomy. Fifty-six percent of these patients were clinically and biochemically cured; 28% were improved and had normal blood pressure values during drug treatment. In contrast, patients with bilateral hyperplasia were treated pharmacologically, but only in half of the patients could normal blood pressure values be achieved. Two thirds of the male patients developed gynecomastia during spironolactone treatment. As expected, unilateral adrenalectomy was unsuccessful in the 7 patients with bilateral hyperplasia who underwent surgery. Our results confirm that surgical treatment of adrenal adenomas and drug treatment of bilateral hyperplasias are the appropriate therapy in primary aldosteronism. A differential diagnosis cannot be made on the basis of clinical and non-invasive laboratory data alone; imaging techniques have to be included in the diagnostic process. The long-term clinical outcome was more favorable in patients with an adrenal adenoma that can be removed surgically than in patients with idiopathic hyperplasia of both adrenal glands.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-1561
    Keywords: Lepidoptera ; Pyralidae ; sex pheromone ; (Z,E)-9,11,13-tetradecatrienal ; mimic ; (Z,E)-7,9,11-dodecatrienyl formate ; wind tunnel ; attractant ; electrophysiology ; receptor cell
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract The behavioral and electrophysiological activity of a mimic [(Z,E)7,9,11-dodecatrienyl formate] of the major sex pheromone component [(Z,E) 9,11,13-tetradecatrienal] of carob moth was assessed. Wind-tunnel bioassays demonstrated that the formate was as effective as natural gland extracts, and significantly more effective than the trienal alone or than the trienal blended with two minor pheromone components, in evoking source contact. Dispensers containing the formate were as effective as trienal-containing blend lures in attracting males when placed at the same dosage in traps in date gardens. Single-cell recordings showed that at least two olfactory neurons, differentiated by spike amplitude, are located in the long trichoid hairs on male carob moth antennae. Dose-response relationships indicated that puffs from cartridges loaded with at least 0.1 μg of the formate or of the trienal were necessary to elicit spiking by either the small or the large-spiking cell within a sensillum. Cross-adaptation studies demonstrated that both compounds stimulated the same large-spiking cell. The frequencies of spikes evoked from the large cell when stimulated by emissions from 0.1-μg, 1-μg, or 10-μg cartridges of either the formate or the trienal were not significantly different, suggesting that the formate is an effective mimic of the trienal at the antennal receptor cell level.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-1561
    Keywords: Flight tunnel ; gas chromatography-electrophysiology ; mass ; spectrometry ; aldehydes ; (Z,E)-9,11,13-tetradecatrienal ; (Z,E)-9,11-tetra-decadienal ; (Z)-9-tetradecenal ; pheromone ; Lepidoptera ; Pyralidae
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract Three sex pheromone components of the carob moth were isolated and identified from the extract of female pheromone glands, using a variety of techniques including coupled gas chromatographic-electroantennographic recordings, coupled gas chromatographic-mass spectrometric analysis, microozonolysis, electroantennographic assays of monounsaturated standards, wind-tunnel bioassays, and field trials. The major component was identified as (Z,E)-9,11,13-tetradecatrienal, a novel lepidopterous pheromone component structure. Two minor components, either one of which improves the upwind flight response of males when blended with the major component, were identified as (Z,E)-9,11-tetradecadienal, and (Z)-9-tetra-decenal.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0009-286X
    Keywords: Dosieren ; Schüttguttechnik ; Schneckendosierer ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 65 (1993), S. 1088-1090 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0009-286X
    Keywords: Oszillierende Verdrängerpumpen ; Druckschwingungen ; Pulsationsdämpfung ; Blenden ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Developments in dosage of bulk solids. Dosage of bulk solids is a fast developing field of process- and production automation. Developments are determined directly by the current demands of the production process, with the properties of the bulk solids and the process itself playing an important role. A survey of proven dosage techniques from the viewpoint of the operating principles, properties, applications, and limitations demonstrates the great variety of problem solutions. An important difference between the individual dosage techniques is the nature and accuracy of mass limitation. The most accurate techniques are the gravimetric dosage methods, with discontinuous weighing giving the greatest accuracy. Developments have been greatly influenced by the state of weighing cell techniques, weighing electronics and computer engineering. The development of measured data acquisition and processing of control, and of instrumentation are described, compared, and assessed. A trend towards system responsibility and development on the part of manufacturers is noted. A accurate dosage of bulk solids requires constant flow of the solids and finely adjustable control devices. The principal interferences in bulk solids flow and measures for their avoidance are shown by means of examples. Successful solution of dosage tasks ultimately requires agreement between manufacturers and processors with regard to definition, determination, and control of dosage accuracy during calibration and during long term operation.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 64 (1992), S. 784-785 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Stirring Devices in Screw Metering Equipment - Action and Design Strategy. The accurarcy of metering by screw dosage equipment with or without gravimetric control depends primarily on the flow of material to the discharging screw. In the case of cohesive solids, stirring devices are generally required to prevent bridging. Experimental observations show that flow conditions correlate directly with the intensity of stirring. Mass flow in the metering container and hence optimum constancy of metering are attainable only from certain stirring efficiencies upwards. Cases of interference to metering due to poor flow of solids can be explained and overcome by modified dimensioning. The effects of the principal parameters - geometry and speed of rotation of the stirrer - are studied with the aid of two stirrer configurations - viz. overhead and concentric. Straightforward model calculations provide a mathematical method of estimation for optimum and reliable stirrer dimensioning also applicable to strongly cohesive solids.
    Additional Material: 22 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Pressure Pulsations Caused by Reciprocating Pumps in Piping Systems. The safe design of piping installations for reciprocating pumps requires proper knowledge about the pump/installation interaction. In many cases critical resonance effects can be avoided by proper piping geometry or improved pump performance with respect to the volumetric efficiency (primary measures). Normally it is necessary to use various secondary dampening methods which can influence the acoustics of the piping system. Several examples of experimental computer simulations of damper action - upstream and downstream - are presented for fluidand gas-filled damper versions. The influence of entry geometry of the dampers is explained, hints on the proper geometry of the entries are given and the effects of various dampers and their influence on the total acoustics are discussed. Special reference is made to the effect of orifices as dissipative and acoustic elements in piping systems. The investigation shows the importance of analyzing of the total system of pump, piping installation and vessels or reactors and the application of computer simulation for piping design.
    Additional Material: 28 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...