GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1
    ISSN: 1432-0738
    Keywords: Key words Classification and transportationrequirements ; Limit tests ; Haber’s rule limit test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Asbtract The EU regulatory statute for the acute hazard identification of chemicals requires selection of the two most appropriate routes of administration. Testing employing the oral route is mandatory, whereas selection of the dermal or inhalation route requires expert judgement, i.e. considerations of structural alerts with regard to the inherent acute inhalation toxicity as well as the likelihood of dermal and inhalation exposure, respectively. Currently, testing of chemicals requires acute inhalation exposure of 4-h and 1-h durations according to EU classification and labelling and UN Transport Guidelines, respectively. The analysis made revealed that 1-h exposures appear to add little knowledge in addition to existing 4-h LC50 values and a default value of 4 should be used for conversion of 4-h to 1-h LC50 values, independently of the physical state of the chemical. Therefore, also the unit of concentration of exposure atmospheres should be independent of nominal features of the test substance. Hence, the preferred dose metric is mass (mg/litre air) rather than volume (ppm). Taking into account the overall variability of acute toxicity data the recommendations given are classification into the following groups of 4-h LC50 values: ?0.05, 〉0.05–0.2, 〉0.2–1, 〉1−5 and 〉5.0 mg/l. No distinction should be made concerning vapours and aerosols with regard to units and conversion factors from 4-h to 1-h LC50 values and the default factor of 4 appears to be most suitable. Further differentiation of classification is not indicated due to technical variability of acute inhalation testing and resolution of the acute bioassay.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1862-0760
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract First reproducible results from potentiometric investigations with chromite electrodes on YSZ have shown a similar behaviour as the well known gold electrodes. Based on these experiences, oxide components particularly gallium doped lanthanum chromites with a perovskite structure and their chemical characterisation will be introduced. Several methods were used for the preparation of the chromite powders in various compositions. In addition, the structural and spectroscopic characterization and the results of potentiometric measurements of the corresponding electrode will be described.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...