GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1420-9136
    Keywords: Key words: Deformation apparatus, ultra-high pressure metamorphism, pressure vessel, solid and molten confining medium, friction.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract —A deformation apparatus has been developed to study the mechanical behaviour of high pressure and ultra-high pressure metamorphic rocks. It is based on the conventional Griggs design and the molten salt cell concept introduced by H. E. Green II. Both, the axial loading and the confining pressure are servohydraulically controlled. Alternatively, a self-made multilayer pressure vessel or a commercial stripwound construction are used. The pressure cell is improved with respect to systems described previously by the use of different salt mixtures with low eutectic temperatures, by a mechanically stable arrangement of the thermocouples, and by an optimization of the frictional characteristics of the axial loading system. The apparatus has been successfully used in deformation experiments on cylindrical aragonite and coesite samples 3 to 4 mm in diameter and 6 to 10 mm in length at confining pressures up to 3.7 GPa and temperatures up to 1170°C.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-9949
    Keywords: Total Hip Replacement ; Electrotherapy ; Pulsed Electromagnetic Fields ; Ultrasonography ; Tc99m Bone Scintigraphy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Aseptic loosening is the most common problem of hip arthroplasties, limiting its long term success. We report a study of pulsed electromagnetic field (PEMF) treatment in 24 patients with this complicatin. At the end of treatment, six months and one year later, pain and hip movements improved significantly with the exception of flexion and extension. There was significant improvement in both isotope scans and ultrasonography, but not in plain X-ray. The decreased pain and improved function suggest that PEMF is effective in improving symptoms of patients with loose hip replacement. No improvement, however, can be expected in patients with severe pain due to gross loosening.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...