GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
Document type
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of cardiovascular electrophysiology 7 (1996), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: High-Frequency Defibrillation. Introduction: Capacitor-discharge type waveforms are practical for defibrillation devices but may not be optimum. Discharging a capacitor as a series of high-frequency (HF) pulses may allow effective waveform shaping by modulating the pulses. This approach could lead to improved defibrillation by allowing waveforms that would otherwise be unachievable with a capacitor-discharge approach. However, little is known about defibrillation with HF. Methods and Results: In open chest pentobarbital anesthetized dogs, we measured defibrillation thresholds for continuous rectangular waveforms with 5-, 10-, and 20-msec durations and for 10- and 20-msec long series of HF rectangular pulses. HF series bad a 50%“on-time” duty cycle at 100 Hz to 20 kHz. At 1 kHz and above, defibrillation with HF required the same time-averaged current but approximately twice the peak current and energy as defibrillation with continuous waveforms having the same envelope duration. At lower frequencies, defibrillation peak current and energy approached values required for the continuous waveforms. While waveforms were not actually filtered, the heart responded as though the HF series were low-pass filtered. A filtered effective waveform model with a 3.7-msec time constant predicts these HF data and makes reasonable predictions for various continuous waveform shapes. Conclusion: Defibrillation is possible using HF pulses up to 20 kHz and has a frequency response similar to a low-pass filter. A filtered effective waveform model predicts these HF results and may help explain bow waveforms influence defibrillation efficacy. While the unmodulated HF pulsing used in this study increased defibrillation requirements, these findings support the concept that HF pulse modulation can be used to change the effective shape of a waveform, which could permit more efficacious waveform shapes and a net reduction of thresholds.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...