GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • SAGE Publications  (1)
  • 1995-1999  (1)
  • 1
    In: Journal of Cerebral Blood Flow & Metabolism, SAGE Publications, Vol. 16, No. 5 ( 1996-09), p. 781-793
    Abstract: Recently, two methods have been proposed for regional cerebral blood flow (rCBF) quantitation using [ 123 I]iodoamphetamine (IMP) and single-photon emission computed tomography (SPECT). The table look-up (TLU) method has been shown to provide both rCBF and volume of distribution, V d , images from two SPECT scans, while a single-scan autoradiographic (ARG) technique provided rCBF using a fixed and assumed V d . In both methods, a single blood sample was referred to calibrate the previously determined standard input function The present multicenter project was designed to evaluate the accuracy of both methods for use as clinical investigative tools. Ten independent institutions performed [ 123 I]IMP-SPECT studies according to both methods in 76 subjects (10 normal volunteers, 32 patients with cerebrovascular disease, and 34 patients with other diseases). Calculated rCBF values were compared with those obtained by the following reference methods available in the participating institutions; [ 15 O] H 2 O positron emission tomography (PET) (five institutions), [ 133 Xe]SPECT (four institutions), and the [ 123 I]IMP microsphere method (three institutions). Both ARG and TLU methods provided rCBF values that were significantly correlated with those measured by the [ 15 O] H 2 O PET technique ( p 〈 0.001 for all subjects; overall regression equation, y = 15.14 + 0.54×) and those measured by the [ 123 I]IMP-microsphere method ( p 〈 0.001 for all subjects; y = 2.0 + 0.80×). Significant correlation ( p 〈 0.05) was observed in 18 of 24 subjects studied with the [ 133 Xe] SPECT reference technique (overall regression equation, y = 15.0 + 0.55×). Mean cortical gray matter rCBF in a group of normal subject was 43.9 ± 3.3 and 43.4 ± 2.0 ml/min/100 g for the ARG and TLU methods, respectively. Regional V d of [ 123 I]IMP estimated by the TLU method was 45 ml/ml ± 20% in the normal cortical region. Close agreement between ARG and TLU rCBF values was observed (y = −3.21 + 1.07×, r = 0.97), confirming the validity of assuming a fixed V d in the ARG method. Results of this study demonstrate that both the ARG and TLU methods accurately and reliably estimate rCBF in a variety of clinical settings.
    Type of Medium: Online Resource
    ISSN: 0271-678X , 1559-7016
    Language: English
    Publisher: SAGE Publications
    Publication Date: 1996
    detail.hit.zdb_id: 2039456-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...