GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 21 (1977), S. 1795-1800 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The rejection of calcium and/or magnesium ion by asymmetric cellulose acetate hyperfiltration membranes is increased significantly by formation of the corresponding alkaline-earth metal chelate. Typically solute fluxes are reduced by a factor of 5 consequent to chelation with ethylenediaminetetraacetic acid (EDTA) at pH 6.0. Selective chelation and, in turn, selective transport of magnesium is observed when equimolar solute mixtures corresponding to 1:1:1 magnesium:calcium:EDTA are hyperfiltered. Under these conditions, calcium successfully competes for the stoichiometrically limiting EDTA, and the rejection of magnesium is lower than the rejection observed for the hyperfiltration of the MgEDTA2- complex in the absence of competitive calcium. Alternatively, the rejection of the CaEDTA2- complex is increased under these identical conditions, presumably as a consequence of specific interactions between the available free magnesium and the cellulose acetate membrane. The effects reported here all seem to be related to reductions in solute diffusivity associated with the increased size of the alkaline-earth metal ion complex.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 33 (1995), S. 1161-1168 
    ISSN: 0887-624X
    Keywords: microemulsion ; polymerization ; methyl methacrylate ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polymerization of methyl methacrylate (MMA) has been studied in ternary microemulsions which were stabilized by tetradecyltrimethylammonium bromide (TTAB) or stearyltrimethylammonium chloride (STAC). The sizes of MMA-swollen polymer particles (Rh) increased continuously during polymerization. This is in contrast to that of the styrene system, where Rh increased very rapidly to a maximum and then decreased continuously towards a constant value. The continuous growth of PMMA particles at 60°C are discussed. The stability of PMMA latexes increased with increasing the hydrophobic chain length of the cationic surfactant used. Traces of the coagulations of PMMA particles in the TTAB system can be seen from TEM. © 1995 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 34 (1996), S. 2095-2102 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Effects of hard segment type, soft segment type, soft segment length, and crystallization at various levels of reactive diluent have been studied in polyurethane acrylates. PTMG-IPDI-based PU acrylates gave better soft segment-hard segment phase separation as compared with PTMG-TDI-based ones. Among PTMG-, PCL-, and PTAd-IPDI-based materials, only PTMG-based one gave clean phase separation, and PTAd-based gave the poorest phase separation. With greater phase separation, higher modulus was obtained. Crystallization of soft segment in PTAd-IPDI-based material gave a significant increase in tensile modulus and elongation at break, with a notable difference in dynamic mechanical properties. © 1996 John Wiley & Sons, Inc.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 42 (1996), S. 332-346 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The flows generated in vessels stirred by two Rushton impellers were investigated in two vessels of diameter (T) 100 and 294 mm with impellers of diameter D = T/3 using flow visualization, power consumption, mixing time, and 360° ensemble-averaged and 1° angle-resolved LDA measurement techniques. The flows depended strongly on the clearance of the lower impeller above the base of the vessel (C1), the separation between the impellers (C2), and the submergence (C3) of the upper impeller below the top of the liquid column height (H). When these distances were varied, three stable and four unstable flow patterns were observed. Comparisons between the two LDA techniques showed that while the 360° ensemble-averaged measurements are useful for characterizing the overall flow structure and turbulence levels in the vessel, care must be exercised when interpreting such data, since in the impeller region they include periodic variations in the mean velocity in addition to the turbulent fluctuations. The trailing vortex structure and flow periodicity produced by the Rushton impellers is shown to decay significantly within a cylindrical region of height 1.2D and radius 1.0D centered around the middle of the vessel, when C1 = C2 = T/3. The turbulence structure within this region is anisotropic, while outside this region it might be considered mostly isotropic. The main flow features scaled well between the vessels.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 423-428 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, nickel ; „Transevaporator“ into packed pre-column as sampling technique prior capillary described ; Application to volatile metabolite body fluid analysis for early detection of disease ; Serum and human breast milk as examples ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Nickel capillary columns coated with moderately polarstationary phases such as Witconol can be used for the separation of the organic volatile fraction from biological fluids. A “transevaporator” sampling technique for the collection of the organic volatiles on glass beads from as little as 5 to 500 μl of biological fluids (e.g. urine, serum, amniotic fluid, breast milk, saliva, etc.) is described. The organic volatiles are thermally desorbed from the glass beads into a short precolumn cooled in liquid nitrogen, which overcomes the problems associated with sample introduction onto narrow-bore capillary columns. The application of the full analytical technique to problems associated with the early detection of disease is illustrated.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 667-675 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A scheme of on-line optimizing control is presented for a nonadiabatic fixed bed reactor which experiences a highly exothermic reaction. The control scheme has been devised to perform adaptive control of bed temperature and on-line steady state optimization simultaneously.Experiments were conducted with a pilot scale fixed bed reactor where partial oxidation of n-butane to maleic anhydride occurs. The reactor system was interfaced with a microcomputer for real-time control and optimization. With an objective function consisting of a net profit by producing maleic anhydride plus a penalty term on high bed temperature, it was clearly shown that the reaction conditions were driven to the expected optimum region.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 33 (1995), S. 1-14 
    ISSN: 0887-6266
    Keywords: poly (p-phenylene terepthalamide) ; Kevlar® ; heat treatment ; structure development ; mechanical properties ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The evolution of several structural characteristics during isothermal heat treatment of poly(p-phenylene terephthalamide) was studied. In this work, heat treatment was interrupted after different treatment times, with the specimens immediately quenched to room temperature. These specimens were then characterized by tensile testing, wide- and small-angle x-ray scattering, and optical microscopy. Structural parameters obtained from these measurements relate to crystal perfection (via the paracrystalline axial distortion parameter), axial crystallite size, transverse crystallite size, degree of chain misorientation, and degree of pleating. Structural and mechanical parameters were then plotted against heat-treatment time to obtain kinetic isotherms for each parameter. The kinetics of the removal of chain misorientation parallels that of tensile modulus increase under all conditions. Of the other structural parameters, only the kinetics of pleat removal mimics that of modulus change, indicating that pleat removal is the effective cause of increased chain alignment and thereby of increased axial stiffness. ©1995 John Wiley & Sons, Inc.
    Additional Material: 27 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 59 (1996), S. 1271-1279 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Two types of dense poly(vinyl alcohol) (PVA) membranes crosslinked with glutaraldehyde were prepared by a new solution technique: membranes with uniform crosslinking structure and with crosslinking gradient structure. From the permeation of pure water through a membrane having a uniform crosslinking structure, the effect of crosslinking density in the membrane on the permeation activation energy, plasticizing coefficient, and diffusivity of the permeant was investigated. The concentration and activity profiles of the permeant in the membrane in the pervaporation process were determined using the diffusion equation and Flory-Huggins thermodynamics. PVA membranes having a crosslinking gradient structure were fabricated by exposing one side of the membrane to the reaction solution while the other side was blocked by a polyester film to prevent the reaction solution from contacting it. The extent of the gradient was controlled by the exposing time. The pervaporation separation of the water-acetic acid mixture was carried out on the membrane having a crosslinking gradient structure, and the pervaporation performance with different membrane loading in the membrane cell was discussed using a schematic concentration and activity profiles of the permeant which was made based on the results from the permeation of a pure component through the membrane with a uniform crosslinking structure. © 1996 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 62 (1996), S. 1561-1576 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The pervaporation separation of a concentrated ethanol-water mixture with 90 wt % of ethanol content through a sodium alginate (SA) membrane was carried out to investigate both the relaxation process and permeation behavior of the membrane in pervaporation. From the swelling measurement of the membrane in 90 wt % of ethanol content of the aqueous solution, it was observed that SA has an excellent permselectivity toward water and a high solubility of water: about 1000 of sorption selectivity and 21 wt % of water content in the swollen membrane at 40°C. Its excellent sorption properties could result in the outstanding pervaporation performance for the aqueous solution; higher than 10,000 of separation factors and 120-290 g/(m2h) of fluxes, depending on the operating temperature. However, a serious flux decline took place with operating time due to the occurrence of a significant relaxation process in SA. The flux decline was remarkable at the beginning stage and then mitigated with operating time. The fluxes were reduced by about 40-50% because of the relaxation process during the measurement. To analyze these phenomena in more detail, the hysteresis behavior of membrane performance along with an operation temperature cycle was investigated. During the heating process in the cycle, the relaxation process was important to affect membrane performance while the formation of excess stress in the membrane might be a crucial factor during the cooling process. It was postulated from the experimental observations that in the heating process an increase in flux with temperature is restricted by a more rapid relaxation process at a higher operation temperature, while in the cooling process, the excess stresses in the membrane are formed and accumulated in and near the transition zone and near the area in the membrane because of slower relaxational consolidation in unequilibrium cooling than in relaxational dilation in the heating process, resulting in flux more sensitive to temperature than in the heating process. These phenomena were found diminished as the relaxation time increased with aging time. The relaxation phenomena were discussed through an analysis on permeation activation energy data obtained from the pervaporation experiments. A qualitative model was established to describe the relaxation phenomena in the membrane material during the pervaporation process by using the basic principles of polymeric relaxation and the experimental observations obtained in this study. © 1996 John Wiley & Sons, Inc.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1315-1320 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Matrix-assisted laser desorption/ionization (MALDI) was used for several small proteins (such as insulin) and for peptides. It was found that the detection efficiencies of MALDI for the insulin B chain and the insulin A chain are drastically different. Similar phenomena were also observed for various types of peptides. The positive-ion signal of MALDI in detecting proteins or peptides was found to be greatly enhanced by the presence of a basic amino acid in their chains. The experimental results indicate that this enhancement may arise from proton transfer in solution by an acid-base reaction between the protein/peptide and matrix molecule. This pre-protonated mechanism provides a low energy barrier for the ionization of peptides in a MALDI process, and greatly reduces the energy threshold of MALDI. Matrix effects on the ionization mechanism are discussed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...