GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 27 (2004), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The aim of the study was to define the impact of different high-pass filter settings (HPF) on the accuracy of mapping of ectopic atrial tachycardias (EAT) using a noncontact mapping (NCM) system. In 20 patients with 22 EAT a noncontact probe was deployed in the right (n = 19) or in the left atrium (n = 3). The device enables interpolation and analysis of unipolar electrograms. It provides information on focus localization and signal morphology. These parameters were compared in different HPF of 0.5 Hz, 2 Hz, 8 Hz, and 16 Hz. The NCM signal morphology was preserved at all HPF. An initial negative deflection recorded by NCM system showed a positive predictive value of 93% regarding the ablation success. The deviation (spatial disparity) between visualized focus origin and successful ablation site was 6.9 ± 5.4 mm. Between two consecutive filter settings, the focus shift was more pronounced between 0.5 and 2 Hz (5.4 ± 4.5 mm) compared to a setting between 8 and 16 Hz (2.9 ± 2.9 mm; P 〈 0.05). Successful ablation was achieved in 15/18 right atrial tachycardias (83%) and in 2/3 left atrial arrhythmias. Different HPF influence NCM spatial analysis of EAT. However, a small variability in foci localization does not impact final ablation results. (PACE 2004; 27:38–46)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BÉCANE, H.–M., et al.: High Incidence of Sudden Death with Conduction System and Myocardial Disease Due to Lamins A and C Gene Mutation. We studied 54 living relatives from a large French kindred, among which 17 members presented with a cardiomyopathy transmitted on an autosomal dominant mode. Five of these individuals had clinical manifestations of muscle disease phenotypically consistent with Emery-Dreifuss muscular dystrophy. Genetic analysis of this kindred had demonstrated a nonsense mutation in the LMNA gene located on chromosome 1q11–q23. This gene encodes lamins A and C, proteins of the nuclear lamina located on the inner face of the nuclear envelope. We retrospectively determined the cause of death of 15 deceased family members, 8 of whom had died suddenly, 2 as a first and single manifestation of the disease. The six other cases had histories of arrhythmias and left ventricular dysfunction before dying suddenly, and three of them died despite the prior implantation of a permanent pacemaker. The mean age of onset of cardiac symptoms among affected living family members was 33 years (range 15–47 years), and the first symptoms were due to marked atrioventricular conduction defects or sinus dysfunction, requiring the implantation of permanent pacemakers in seven cases. Myocardial dysfunction accompanied by ventricular arrhythmias developed rapidly in the course of the disease and resulted in severe dilated cardiomyopathy requiring cardiac transplantation in three cases. In conclusion, in patients presenting a life-threatening familial or sporadic cardiac restricted phenotype similar to that described here, mutations in the lamins A and C gene should be looked for. In the genotypically affected individuals, cardiological and electrophysiological follow-up should be performed to prevent sudden death that could occur rapidly in the evolution of such disease.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , U.S.A . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: WEBER, S., et al .: Prevalence of T Wave Alternans in Healthy Subjects. Beat-to-beat variations in the amplitude of the T wave (T wave alternans [TWA]) have been associated with malignant ventricular arrhythmias in patients with structural heart disease. TWA has also been observed sporadically in healthy persons during strenuous exercise. Therefore, it was the aim of this study to investigate the prevalence of TWA in healthy subjects at rest and during exercise. TWA was assessed in 48 healthy volunteers with a mean age of 30 ± 8 years (21–53 years) using the CH2000 system for measurement of microvolt level TWA. TWA was not observed in any individual at rest. Short transient intervals of TWA were observed during exercise in five (10.4%) subjects. Sustained TWA was observed in two (4.2%) individuals. In one of these two individuals sustained TWA was recorded at heart rates 〉110 beats/min. In the other TWA was observed at an onset heart rate of 〈110 beats/min, and therefore, was considered alternans positive. The prevalence of exercise related sustained TWA in healthy, young individuals is low (2.1%). Short transient intervals of TWA were observed in about 10% of healthy volunteers. These transient episodes of TWA had no clinical impact with respect to a higher vulnerability to ventricular arrhythmias. (PACE 2003; 26[Pt. I]:49–52)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: SCHWAB, J.O., et al.: Incidence of T Wave Alternation After Acute Myocardial Infarction and Correlation with Other Prognostic Parameters: Results of a Prospective Study. Tachycardia induced alternation of the T wave (TWA) has been associated with arrhythmia morbidity in mixed patient populations. However, less is known concerning the general incidence of TWA and its usefulness in risk stratification early after acute myocardial infarction (MI). TWA was prospectively and systematically assessed in 140 consecutive patients 15 ± 6 days after acute MI and prior to discharge. Results of TWA measurements were compared to other noninvasive risk markers, LV function, and coronary angiography. Sustained TWA was present at rest or inducible during exercise in 27% of patients. The patient-specific heart rate for the onset of TWA was 98 ± 9 beats/min. After multivariate analysis, TWA correlated with age (P = 0.02) and LV function (P = 0.002) and occurred more often in patients after nonanterior MI (P = 0.03). Acute results of Holter monitoring, late potentials by signal-averaged ECG, and heart rate variability were unrelated to the TWA status. During follow-up (451 ± 210 days) two major arrhythmic events occurred. The incidence of TWA early after MI is about 25%. TWA is related to age and LV function but not to other common arrhythmia markers. Although TWA does not appear to be related to excessive cardiac morbidity, evaluation of the prognostic significance of TWA requires further study.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 25 (2002), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: GRADAUS, R., et al.: Effect of Ventricular Fibrillation Duration on the Defibrillation Threshold in Humans. Early during ventricular fibrillation, the defibrillation threshold may be low, as ventricular fibrillation most probably arises from a localized area with only a few wavefronts and the effects of global ischemia, ventricular dilatation, and sympathetic discharge have not yet fully developed. The purpose of this study was to explore the effect of the timing of shock delivery in humans. During implantation of an ICD in 26 patients (24 men, 60 ± 11 years, 19 coronary artery disease, NYHA 2.2 ± 0.4, left ventricular ejection fraction 0.42 ± 0.16), the defibrillation threshold was determined after approximately 10 and 2 seconds of ventricular fibrillation. Ventricular fibrillation was induced by T wave shocks. Mean defibrillation threshold was 9.9 ± 3.6 J after 10.3 ± 1.0 seconds. Within 2 seconds, 20 of 26 patients could be successfully defibrillated with ≤ 8 J. In these patients, the mean defibrillation threshold was 4.0 ± 2.1 J after 1.4 ± 0.3 seconds compared to 9.5 ± 3.1 J after 10.2 ± 1.1 seconds (P 〈 0.001). There were no clinical differences between patients who could be successfully defibrillated within 2 seconds and those patients without successful defibrillation within 2 seconds. In the majority of patients, the defibrillation threshold was significantly lower within the first few cycles of ventricular fibrillation than after 10 seconds of ventricular fibrillation. These results should lead to exploration of earlier shock delivery in implantable devices. This could possibly reduce the incidence of syncope in patients with rapid ventricular tachyarrhythmias and ICDs.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 24 (2001), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: WEBER, M., et al.: Antitachycardia Pacing for Rapid VT During ICD Charging: A Method to Prevent ICD Shocks. In patients with ICDs, rapid VTs are usually treated with shocks. It is unknown, if antitachycardia pacing (ATP) delivered once for rapid VT during capacitor charging can avoid painful shocks without increasing the risk of syncope. In patients in whom rapid monomorphic VT (cycle length 300–220 ms) could be reproducibly induced during predischarge ICD testing, the success of cardioversion (defibrillation threshold plus 10 J) and a single ATP attempt (burst with 8 or 16 stimuli) was compared using a randomized crossover study design. Consciousness of the patients was checked by the signal from a button constantly pushed by the patient. In 20 patients (ejection fraction 0.50 ± 0.19) rapid VTs (253 ± 26 ms) were reproducibly induced. A single burst successfully terminated 11 (55%) of 20 rapid VTs, 6 episodes could not be terminated with a single burst pacing and 3 VTs accelerated. Rapid VTs not terminated by ATP were significantly faster than those that could be terminated (246 vs 258 ms, P = 0.026). Cardioversion (19 ± 3 J) terminated the VTs in all cases. No patient suffered syncope during rapid VTs. A single ATP may terminate rapid VT with cycle lengths 〈 300 ms in 55% of patients without increasing the risk of syncope. Therefore, in rapid VTs one attempt of ATP may be suitable as an additional therapy option during ICD capacitor charging to avoid painful shocks without compromise of safety. Thus, future ICDs should implement the option of ATP during charging of capacitors.