GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (11)
  • Analytical Chemistry and Spectroscopy  (7)
  • 550 - Earth sciences  (4)
  • Captopril  (2)
  • Chemical Engineering  (2)
  • 2005-2009  (4)
  • 1995-1999  (6)
  • 1985-1989  (15)
  • 1965-1969  (1)
Document type
Keywords
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 64 (1986), S. 327-332 
    ISSN: 1432-1440
    Keywords: Severe hypertension ; Minoxidil ; Captopril
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The antihypertensive efficacy of minoxidil and captopril was compared in 23 males with essential or renal parenchymatous hypertension refractory to conventional antihypertensive drug therapy. Following a pretreatment period the patients were randomly assigned to receive either minoxidil, 2.5 mg twice daily (n=12), or captopril, 25 mg twice daily (n=11). In patients with diastolic blood pressure 〉95 mmHg, doses of minoxidil and captopril were increased in 2-week intervals. Patients who maintained diastolic pressure 〉95 mmHg and/or those with intolerable side effects were switched over to the alternative substance. After a mean observation period of 12 weeks a significant decrease in systolic and diastolic blood pressure was observed (179/114 vs 148/92 mmHg in the minoxidil group; 176/111 vs 158/97 mmHg in the captopril group). The primary response rate was 75% in patients treated with minoxidil and 55% in those with captopril (not significant). After the change to the alternative substance two of the four non-responders on captopril and one of the two non-responders on minoxidil became responders. Side effects occurred significantly more often during minoxidil than captopril (p〈0.05). The high efficacy of minoxidil and captopril in the treatment of severe hypertension refractory to conventional drugs was confirmed. Minoxidil lowered blood pressure slightly more than captopril, but it had a higher incidence of side effects than captopril.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 63 (1985), S. 361-363 
    ISSN: 1432-1440
    Keywords: Primary aldosteronism ; Captopril ; Spironolactone ; Renin-angiotensin ; Converting-enzyme ; Secondary hypertension
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary In three patients with primary aldosteronism, the acute effect of a single dose of captopril on the elevated mean arterial blood pressure (MAP) was studied before and after 4 weeks of treatment with spironolactone. Before spironolactone therapy, captopril did not cause any drop in MAP. Four weeks later, after an oral daily dose of 400 mg spironolactone, MAP was still elevated in all three patients, though electrolyte abnormalities were fully corrected. Since plasma renin activity (PRA) was increased to values above the normal range, the acute effect of captopril on MAP was tested again. A single dose of 25 mg captopril then caused a fall in MAP to normal. These data reveal the conversion from a renin-independent to a renindependent kind of hypertension after spironolactone therapy in three patients with primary aldosteronism syndrome. This might be of pathogenetic and therapeutic interest.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 33 (1987), S. 319-321 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 20 (1997), S. 85-93 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Modified cyclodextrin phases ; Chiral organochlorines ; Biological samples ; Enantiomeric ratios ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Four chiral stationary phases containing modified cyclodextrines diluted in or chemically bonded to a non-chiral phase were used to resolve chiral organochlorine compounds such as α-hexachlorocyclohexane (α-HCH), perdeuterated α-HCH (α-PDHCH), β-and γ-pentachlorocyclohexene (PCCH), oxychlordane, cis-and trans-chlor- dane, cis- and trans-heptachlorepoxide, PCB 95, PCB 132, PCB 149, and Chiral tozaphenes.The elution order was determined by analyzing standards with known enantiomeric excesses.Furthermore, an internal standard was used to even out slight variations in the ratio of peak hights of enantiomers which were determined from injection to injection.None of the chiral stationary phases resolved all chiral organochlorine compounds. However, the β-TBDM(35% heptakis (6-O-t-butyldimethylsilyl-2,3-di-O-methyl)-β-cyclodextrin in OV 1701) column allowed the separation of all compounds under investigation except for PCB 95 and chiral toxaphenes.Emphasis was placed on the separation of as many as possible enantiomers on a chiral phase by application of one temperature program and with respect to unambiguous quantitation of biological samples such as bludder and liver of marine and terrestrial mammals.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 643-646 
    ISSN: 0935-6304
    Keywords: Gas chromatography/Mass spectrometry ; Chiral GC ; Deuterium-labeled compounds ; Hexachlorocyclohexane ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Perdeuterated α-1,2,3,4,5,6-hexachlorocyclohexane (α-PDHCH) was synthesized and isolated in pure form. α-PDHCH was baseline separated from unlabeled α-HCH by high resolution gas chromatography on different stationary phases. α-PDHCH was also resolved into its enantiomeric forms by application of a chiral GC phase. Furthermore, chiral chromatography of a mixture of labeled α-PDHDH and unlabeled α-HCH resulted in four peaks. Standard solutions of α-PDHCH are recommended both as recovery standard for sample clean-up and as internal standard for the quantitation of chlorinated hydrocarbons with GC/MS or GC/ECD in environmental samples.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1022-1336
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The porous copolymer films of N-methacryloyl-L-alanine methyl ester and diethyleneglycol-bis-allylcarbonate (diallyl oxydiethylene dicarbonate) were hydrolyzed with 1 M NaOH solution for 40 min at 25°C. The pores of the films showed pH response in diameter. The pore diameter of 3,7 μm in the buffer solution of pH 3 was closed completely at pH 5.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 27 (1987), S. 1113-1120 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A nonlinear finite element model for the static analysis of football helmets is developed as a first step in a methodology for the mathematical modeling of helmets. Polycarbonate and acrylonitrile-butadiene-styrene are considered as the shell material for the helmet. Such a methodology can be used to predict helmet response to loading and impact and can be incorporated in a computer program studying injuries caused by helmeted head collisions in football. Numerical results in terms of force-deflection curves, maximum stresses, and work of deformation are given. The influence of the polymeric material forming the helmet shell on energy absorption is studied. The effect of the internal padding material and suspension system is also considered.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Flow control for small metering pumps with continuous and pulsating flow. Metering of small flows with high discharge pressure is performed mainly by displacement metering pumps. The necessary mass-flow control shows problems with pulsating piston- or diaphragm metering pumps. A survey explains the presently available continuous and discountinuous methods of mass- and volume flow control. Special investigations have been performed with differential scales and mass flow meters based on the Coriolis- and the thermal principle. The differential weighing method shows good accuracy down to minimum mass flows of 0.1 kg/h. This method is expensive and requires vibration protected installation. The Coriolis flow meter, applicable over a similar range, precisely integrates the pulsating signal, but requires damping or signal averaging for regulation purposes. Thermal flow meters prove rather sensitive to temperature fluctuations. Under stable conditions and with proper calibration this principle may be applied to flows even below 0.1 kg/h.
    Additional Material: 26 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 67 (1995), S. 1184-1185 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 67 (1995), S. 1185-1186 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...