GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2015-10-20
    Description: Understanding the structure of the ocean-continent transition (OCT) in passive margins is greatly enhanced by comparison with onshore analogues. The North Atlantic margins and the "fossil" system in the Scandinavian Caledonides show variations along strike between magma-rich and magma-poor margins, but are different in terms of exposure and degree of maturity. They both display the early stages of the Wilson cycle. Seismic reflection data from the mid-Norwegian margin combined with results from Ocean Drilling Program Leg 104 drill core 642E allow for improved subbasalt imaging of the OCT. Below the Seaward-Dipping Reflector (SDR) sequences, vertical and inclined reflections are interpreted as dike feeder systems. High-amplitude reflections with abrupt termination and saucer-shaped geometries are interpreted as sill intrusions, implying the presence of sediments in the transition zone beneath the volcanic sequences. The transitional crust located below the SDR of the mid-Norwegian margin has a well-exposed analogue in the Seve Nappe Complex (SNC). At Sarek (Sweden), hornfelsed sediments are truncated by mafic dike swarms with densities of 70%–80% or more. The magmatic domain extends for at least 800 km along the Caledonides, and probably reached the size of a large igneous province. It developed at ca. 600 Ma on the margin of the Iapetus Ocean, and was probably linked to the magma-poor hyperextended segment in the southern Scandinavian Caledonides. These parts of the SNC represent an onshore analogue to the deeper level of the mid-Norwegian margin, permitting direct observation and sampling and providing an improved understanding, particularly of the deeper levels, of present-day magma-rich margins.
    Print ISSN: 0091-7613
    Electronic ISSN: 1943-2682
    Topics: Geosciences
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-11-09
    Description: The notorious ~60° bend separating the Hawaiian and Emperor chains marked a prominent change in the motion of the Pacific plate at ~47 Ma (million years ago), but the origin of that change remains an outstanding controversy that bears on the nature of major plate reorganizations. Lesser known but equally significant is a conundrum posed by the pre-bend (~80 to 47 Ma) motion of the Pacific plate, which, according to conventional plate models, was directed toward a fast-spreading ridge, in contradiction to tectonic forcing expectations. Using constraints provided by seismic tomography, paleomagnetism, and continental margin geology, we demonstrate that two intraoceanic subduction zones spanned the width of the North Pacific Ocean in Late Cretaceous through Paleocene time, and we present a simple plate tectonic model that explains how those intraoceanic subduction zones shaped the ~80 to 47 Ma kinematic history of the Pacific realm and drove a major plate reorganization.
    Electronic ISSN: 2375-2548
    Topics: Natural Sciences in General
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2018-03-06
    Description: Over the past 15 yr, numerical models of convection in Earth’s mantle have made a leap forward: they can now produce self-consistent plate-like behaviour at the surface together with deep mantle circulation. These digital tools provide a new window into the intimate connections between plate tectonics and mantle dynamics, and can therefore be used for tectonic predictions, in principle. This contribution explores this assumption. First, initial conditions at 30, 20, 10 and 0 Ma are generated by driving a convective flow with imposed plate velocities at the surface. We then compute instantaneous mantle flows in response to the guessed temperature fields without imposing any boundary conditions. Plate boundaries self-consistently emerge at correct locations with respect to reconstructions, except for small plates close to subduction zones. As already observed for other types of instantaneous flow calculations, the structure of the top boundary layer and upper-mantle slab is the dominant character that leads to accurate predictions of surface velocities. Perturbations of the rheological parameters have little impact on the resulting surface velocities. We then compute fully dynamic model evolution from 30 and 10 to 0 Ma, without imposing plate boundaries or plate velocities. Contrary to instantaneous calculations, errors in kinematic predictions are substantial, although the plate layout and kinematics in several areas remain consistent with the expectations for the Earth. For these calculations, varying the rheological parameters makes a difference for plate boundary evolution. Also, identified errors in initial conditions contribute to first-order kinematic errors. This experiment shows that the tectonic predictions of dynamic models over 10 My are highly sensitive to uncertainties of rheological parameters and initial temperature field in comparison to instantaneous flow calculations. Indeed, the initial conditions and the rheological parameters can be good enough for an accurate prediction of instantaneous flow, but not for a prediction after 10 My of evolution. Therefore, inverse methods (sequential or data assimilation methods) using short-term fully dynamic evolution that predict surface kinematics are promising tools for a better understanding of the state of the Earth’s mantle.
    Print ISSN: 0956-540X
    Electronic ISSN: 1365-246X
    Topics: Geosciences
    Published by Oxford University Press on behalf of The Deutsche Geophysikalische Gesellschaft (DGG) and the Royal Astronomical Society (RAS).
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical and experimental dermatology 12 (1987), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Thirty-five patients with acne vulgaris were studied regarding vitamin A and E status, and the safety and efficacy of vitamin A supplementation over a 6-week period. The patients studied had significantly lower plasma vitamin A levels than normal controls and a lower frequency of consumption of foods rich in vitamin A. Vitamin E status in the patients was similar to that of normal controls. Vitamin A supplementation had no significant effect on plasma vitamin A levels during the study, but the patients had significantly (P〈0.005) higher levels at 6 weeks post-supplementation when compared with pre-supplementation values. Furthermore, vitamin A supplementation was associated with a significant and progressive increase in plasma retinol ester concentration. Vitamin A at the dose administered was ineffective in the treatment of acne and was associated with symptoms compatible with hypervitaminosis A only in a small percentage of patients.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 440 (1985), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Geometriae dedicata 19 (1985), S. 109-174 
    ISSN: 1572-9168
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 229-233 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused-silica capillary ; Wide bore glass capillary ; Packed column ; Plasma amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p 〈 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 509-516 
    ISSN: 0935-6304
    Keywords: Ion exchange chromatography ; HPLC ; GC ; Quantitation ; Amino acids ; Physiological fluids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methodologies for quantitative analysis of amino acids in physiological fluids based on classical ion exchange, high performance liquid chromatography, and gas chromatography are analyzed. As judged by the relative number of reports on these techniques, it appears that classical ion exchange continues to be the main method of choice for amino acid determinations and only limited advantage has been taken of the benefits (e.g. lower capital outlay and running costs and shorter analysis times) offered by other techniques. More importantly, however, there appears to be insufficient quantitative evaluation of the methodologies used. As a result, the validity of many reports based on data from amino acid analysis of physiological samples may be questioned.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 555-560 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused-silica ; Plasma amino acid analysis ; “On-column” injection ; Classical ion exchange ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p 〈 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p 〈 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2020-02-12
    Type: info:eu-repo/semantics/article
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...