GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (3)
  • 2020-2024  (3)
Material
Publisher
  • Ovid Technologies (Wolters Kluwer Health)  (3)
Language
Years
  • 2020-2024  (3)
Year
Subjects(RVK)
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2020
    In:  Nuclear Medicine Communications Vol. 41, No. 9 ( 2020-9), p. 883-887
    In: Nuclear Medicine Communications, Ovid Technologies (Wolters Kluwer Health), Vol. 41, No. 9 ( 2020-9), p. 883-887
    Abstract: Parathyroidectomy is the choice of treatment for patients with primary and tertiary hyperparathyroidism. Scintigraphic, preoperative localization of hyperfunctioning parathyroid tissue depends on either a delayed washout technique, a subtraction technique, or a combination of the two. The rationale for adopting a combination approach is its presumed superior sensitivity, but there is limited evidence to support this strategy at the cost of patient inconvenience and impact on departmental workflows. Objective To determine whether a combined technique detects any additional lesions during scan interpretation compared to using subtraction-only technique in patients undergoing parathyroid scintigraphy before surgery. Methods A retrospective analysis was performed of parathyroid scans at Tygerberg Hospital between January 2012 and April 2018. Scans were reinterpreted by consensus by three readers, blinded to the original interpretation. A McNemar discordant pairs analysis was then performed. Results A total of 97 participant scans were reviewed (female: 71; mean age: 50.8 years). The number of patients with primary, secondary, and tertiary hyperparathyroidism were 63, 21, and 13, respectively. A total of 192 lesions were identified in this study. While both combined and subtraction-only approaches identified hyperfunctioning parathyroid lesions, only four lesions were identified using the combined technique that were missed by the subtraction technique. This result was not statistically significant ( P  = 0.125). Conclusion Based on our findings, the combined parathyroid scintigraphic technique does not improve lesion detection and may be dispensed with. Doing so will enhance patient convenience and comfort and improve departmental workflows without compromising lesion detection.
    Type of Medium: Online Resource
    ISSN: 0143-3636
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2028880-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2021
    In:  Nuclear Medicine Communications Vol. 42, No. 3 ( 2021-03), p. 261-266
    In: Nuclear Medicine Communications, Ovid Technologies (Wolters Kluwer Health), Vol. 42, No. 3 ( 2021-03), p. 261-266
    Abstract: Glomerular filtration rate (GFR) measurement remains an integral investigation in clinical practice and is particularly important in the prediction and follow-up of renal side-effects of nephrotoxic chemotherapy in cancer patients. Knowing the coefficient of variation (CV) of a test is vital for the correct interpretation of serial studies. Recent difficulties with 51 Cr-EDTA availability have renewed interest in 99m Tc-DTPA, but there is a paucity of data on the test-retest variability of this radiopharmaceutical. Furthermore, the authors are unaware of published repeatability data in cancer patients. The aim of this study was to determine the CV of repeat 99m Tc-DTPA GFR measurements in a clinical patient population that included cancer patients. Methods Patients who had undergone ≥2 GFR studies at our department between January 2009 and December 2019 were retrospectively identified. Patients with chronic kidney disease and those who had received chemotherapy, radiotherapy or surgery between measurements were excluded. The CV for each patient was calculated and the mean CVs of cancer and prospective renal donor groups were calculated and compared. Results Fifty-four patients were included in the final analysis. The mean CV in the cancer group (38 patients) was 8.5% [95% confidence interval (CI) 6.9–10.2%] and in the renal donor group (16 patients) 7.1% (95% CI 4.2–10.1%). These figures did not differ significantly ( P = 0.37). The groups were combined to calculate the final overall mean CV of 8.1% (95% CI 6.7–9.6%). Conclusion In both non-cancer and cancer patients the CV of GFR studies performed with 99m Tc-DTPA was comparable with mostly 51 Cr-EDTA figures presented in literature.
    Type of Medium: Online Resource
    ISSN: 0143-3636
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2028880-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2023
    In:  Medicine & Science in Sports & Exercise Vol. 55, No. 9S ( 2023-9), p. 923-924
    In: Medicine & Science in Sports & Exercise, Ovid Technologies (Wolters Kluwer Health), Vol. 55, No. 9S ( 2023-9), p. 923-924
    Type of Medium: Online Resource
    ISSN: 1530-0315 , 0195-9131
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    detail.hit.zdb_id: 2031167-9
    SSG: 31
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...