    In: Stroke, Ovid Technologies (Wolters Kluwer Health), Vol. 52, No. 4 ( 2021-04), p. 1234-1243
    Abstract: High blood pressure increases bleeding risk during treatment with antithrombotic medication. The association between blood pressure levels and the risk of recurrent stroke during long-term secondary stroke prevention with thienopyridines (particularly prasugrel) has not been well studied. Methods: This was a post hoc analysis of the randomized, double-blind, multicenter PRASTRO-I trial (Comparison of Prasugrel and Clopidogrel in Japanese Patients With Ischemic Stroke-I). Patients with noncardioembolic stroke were randomly assigned (1:1) to receive prasugrel 3.75 mg/day or clopidogrel 75 mg/day for 96 to 104 weeks. Risks of any ischemic or hemorrhagic stroke, combined ischemic events, and combined bleeding events were determined based on the mean level and visit-to-visit variability, including successive variation, of systolic blood pressure (SBP) throughout the observational period. These risks were also compared between quartiles of mean SBP level and successive variation of SBP. Results: A total of 3747 patients (age 62.1±8.5 years, 797 women), with a median average SBP level during the observational period of 132.5 mm Hg, were studied. All the risks of any stroke (146 events; hazard ratio, 1.318 [95% CI, 1.094–1.583] per 10-mm Hg increase), ischemic stroke (133 events, 1.219 [1.010–1.466] ), hemorrhagic stroke (13 events, 3.247 [1.660–6.296]), ischemic events (142 events, 1.219 [1.020–1.466] ), and bleeding events (47 events, 1.629 [1.172–2.261]) correlated with increasing mean SBP overall. Similarly, an increased risk of these events correlated with increasing successive variation of SBP (hazard ratio, 3.078 [95% CI, 2.220–4.225] per 10-mm Hg increase; 3.051 [2.179–4.262]; 3.276 [1.172–9.092] ; 2.865 [2.042–4.011]; 2.764 [1.524–5.016] , respectively). Event rates did not differ between the clopidogrel and prasugrel groups within each quartile of SBP or successive variation of SBP. Conclusions: Both high mean SBP level and high visit-to-visit variability in SBP were significantly associated with the risk of recurrent stroke during long-term medication with either prasugrel or clopidogrel after stroke. Control of hypertension would be important regardless of the type of antiplatelet drugs. Registration: URL: https://www.clinicaltrials.jp ; Unique identifier: JapicCTI-111582.
    Type of Medium: Online Resource
    ISSN: 0039-2499 , 1524-4628
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 1467823-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 101, No. 49 ( 2022-12-9), p. e31846-
    Abstract: A prospective multicenter cohort study. To clarify the differences in the accuracy of transcranial motor-evoked potentials (TcE-MEPs) and procedures associated with the alarms between cervical anterior spinal fusion (ASF) and posterior spinal fusion (PSF). Neurological complications after TcE-MEP alarms have been prevented by appropriate interventions for cervical degenerative disorders. The differences in the accuracy of TcE-MEPs and the timing of alarms between cervical ASF and PSF noted in the existing literature remain unclear. Patients (n = 415) who underwent cervical ASF (n = 171) or PSF (n = 244) at multiple institutions for cervical spondylotic myelopathy, ossification of the posterior longitudinal ligament, spinal injury, and others were analyzed. Neurological complications, TcE-MEP alarms defined as a decreased amplitude of ≤70% compared to the control waveform, interventions after alarms, and TcE-MEP results were compared between the 2 surgeries. The incidence of neurological complications was 1.2% in the ASF group and 2.0% in the PSF group, with no significant intergroup differences ( P -value was .493). Sensitivity, specificity, negative predictive value, and rate of rescue were 50.0%, 95.2%, 99.4%, and 1.8%, respectively, in the ASF group, and 80.0%, 90.9%, 99.5%, and 2.9%, respectively, in the PSF group. The accuracy of TcE-MEPs was not significantly different between the 2 groups ( P -value was .427 in sensitivity, .109 in specificity, and .674 in negative predictive value). The procedures associated with the alarms were decompression in 3 cases and distraction in 1 patient in the ASF group. The PSF group showed Tc-MEPs decreased during decompression, mounting rods, turning positions, and others. Most alarms went off during decompression in ASF, whereas various stages of the surgical procedures were associated with the alarms in PSF. There were no significant differences in the accuracy of TcE-MEPs between the 2 surgeries.
    Type of Medium: Online Resource
    ISSN: 1536-5964
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2049818-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Blood Pressure Monitoring Vol. 27, No. 5 ( 2022-10), p. 314-319
    In: Blood Pressure Monitoring, Ovid Technologies (Wolters Kluwer Health), Vol. 27, No. 5 ( 2022-10), p. 314-319
    Abstract: The relationship between the white-coat effect (WCE), defined as white-coat hypertension under treatment, and the frequency of orthostatic hypotension (OH) is not known. We conducted an orthostatic test in patients with WCE to determine the frequency of OH. Methods This was a cross-sectional study of 5631 patients with hypertension visiting general practitioners nationwide, in which 4305 patients with hypertension recorded their home blood pressure (BP) and consented to the orthostatic test. Patients with hypertension were divided into four groups: controlled hypertension (CHT), masked hypertension (MHT), sustained hypertension (SHT), and WCE. The orthostatic test was performed, and BP and pulse rate were measured immediately and 1 min after orthostasis. Results The OH frequencies immediately after standing in CHT, WCE, SHT, and MHT patients were 7, 11.7, 12.1, and 6.6%, respectively, and those at 1 min after standing were 7.1, 13.1, 11.6 and 6.9%, respectively (Chi-square test, P 〈 0.01, respectively). Logistic regression analysis was performed to examine the relationship between WCE and the frequency of OH. The frequency of OH immediately after standing was significantly increased [adjusted odds ratio (AOR), 1.702; 95% confidence interval (CI), 1.246–2.326; P 〈 0.01]. The frequency of OH at 1 min after standing was also significantly higher (AOR, 1.897; 95% CI, 1.396–2.578; P 〈 0.01). Conclusion When the standing test was performed for patients with WCE, the frequency of OH increased. Thus, it is important to recognize the possibility of OH in patients with WCE to avoid adverse events associated with excessive hypotension.
    Type of Medium: Online Resource
    ISSN: 1359-5237
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2029920-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Clinical and Translational Gastroenterology, Ovid Technologies (Wolters Kluwer Health), Vol. 12, No. 9 ( 2021-9-24), p. e00404-
    Type of Medium: Online Resource
    ISSN: 2155-384X
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2581516-7