GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • IOS Press  (2)
  • 2020-2024  (2)
Material
Publisher
  • IOS Press  (2)
Language
Years
  • 2020-2024  (2)
Year
  • 1
    In: Technology and Health Care, IOS Press, Vol. 30 ( 2022-02-25), p. 105-114
    Abstract: BACKGROUND: The results of urine tests are often affected by improper midstream urine collection time, urine spilling, and urine pollution, all of which can lead to an increase in the test error. OBJECTIVE: To solve this problem, aiming at improving the toilet environment at the hospitals and public physical examination centers, this paper designs an automatic urine collection system. It can automatically adjust the position of the urine cup with an infrared remote controller, or manually, adjust the position of the urine cup in special situations according to the needs of the user. It also has an alarm function. METHODS: The overall size and shape are designed based on the squatting pan, suitable for disposable plastic urine cups of different shapes and sizes. It can realize the automatic collection of midstream urine, manual collection in exceptional cases, emergency stops, and rescue calls. RESULTS: Through the trial survey, there was a significant difference between the statistical results of using the device and not using the device (t= 13.937, P= 0.000). 96% of the subjects thought that the design of the system was reasonable, 22% thought that it was inconvenient to use, and 91.7% of the medical staff thought that the system met the sampling requirements. CONCLUSIONS: Therefore, the trial evaluation is satisfactory, and the proposed collection system is suitable for use in hospitals at all levels and public health examination centers with a large amount of inspection.
    Type of Medium: Online Resource
    ISSN: 0928-7329 , 1878-7401
    Language: Unknown
    Publisher: IOS Press
    Publication Date: 2022
    detail.hit.zdb_id: 2043772-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Technology and Health Care, IOS Press, Vol. 30 ( 2022-02-25), p. 469-480
    Abstract: BACKGROUND: Spatial disorientation (SD) is a problem that pilots often encounter during a flight. One reason for this problem is that among the three types of SD, there is no validated method to detect the Type I (unrecognized) SD. OBJECTIVE: In this pursuit, initially we reviewed the problems and the evaluation methods of associated with SD. Subsequently, we discussed the advantages and disadvantages of the subjective questionnaire evaluation method and the behavior evaluation method. METHODS: On the basis of these analyses, we proposed a method to detect the unrecognized SD that improved the assessment of SD to a significant extent. We developed a new direction to study the unrecognized SD based on the subjective report and the center of pressure (CoP). RESULTS: The proposed evaluation method can assist the pilots to understand the feelings and physical changes, when exposed to unrecognized SD. CONCLUSION: We hope that this evaluation method can provide a strong support in developing a countermeasure against the unrecognized SD and fundamentally solve the severe flight accidents arising due to them.
    Type of Medium: Online Resource
    ISSN: 0928-7329 , 1878-7401
    Language: Unknown
    Publisher: IOS Press
    Publication Date: 2022
    detail.hit.zdb_id: 2043772-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗