GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemistry  (4)
  • Analytical Chemistry and Spectroscopy  (2)
  • Aldosterone  (1)
  • Forschungsbericht
  • 1990-1994  (5)
  • 1994  (5)
Document type
Publisher
Years
  • 1990-1994  (5)
Year
  • 1
    ISSN: 1432-1440
    Keywords: Adenoma ; Aldosterone ; Adrenalectomy ; Gynecomastia ; Hyperaldosteronism ; Hyperplasia ; Spironolactone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Since 1974 primary aldosteronism has been diagnosed in 71 patients in our outpatient clinic. Thirty-four patients had a unilateral aldosterone-producing adenoma, whereas bilateral adrenal hyperplasia was diagnosed in 37 patients. Although at the time of diagnosis the mean potassium values were lower and mean aldosterone levels were higher in patients with an adenoma, as compared to those with bilateral hyperplasia, these laboratory data did not allow us to differentiate between the two leading causes of primary aldosteronism in the individual patient due to pronounced overlap of laboratory values between the two groups. During the first few years, a successful differential diagnosis was made by adrenal phlebography and separate sampling of plasma aldosterone in both adrenal veins; later non-invasive imaging techniques such as computed tomography and radionuclide scanning were used. The best results were obtained in patients with adenoma who underwent adrenalectomy. Fifty-six percent of these patients were clinically and biochemically cured; 28% were improved and had normal blood pressure values during drug treatment. In contrast, patients with bilateral hyperplasia were treated pharmacologically, but only in half of the patients could normal blood pressure values be achieved. Two thirds of the male patients developed gynecomastia during spironolactone treatment. As expected, unilateral adrenalectomy was unsuccessful in the 7 patients with bilateral hyperplasia who underwent surgery. Our results confirm that surgical treatment of adrenal adenomas and drug treatment of bilateral hyperplasias are the appropriate therapy in primary aldosteronism. A differential diagnosis cannot be made on the basis of clinical and non-invasive laboratory data alone; imaging techniques have to be included in the diagnostic process. The long-term clinical outcome was more favorable in patients with an adrenal adenoma that can be removed surgically than in patients with idiopathic hyperplasia of both adrenal glands.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry and Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Titanium silicalite-1 samples of different particle size are synthesised and characterised by X-ray diffraction (XRD), photoelectron spectroscopy (XPS), diffuse reflectance spectroscopy (DRS), Raman and infrared spectroscopy. Size histograms are taken from transmission electron micrographs. Temporal changes of activity and selectivity for the hydroxylation of phenol and anisole are monitored. It is postulated that the p/o product ratios are due to the greater chemisorption of the ortho molecule.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 23 (1994), S. 379-379 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Stirring Devices in Screw Metering Equipment - Action and Design Strategy. The accurarcy of metering by screw dosage equipment with or without gravimetric control depends primarily on the flow of material to the discharging screw. In the case of cohesive solids, stirring devices are generally required to prevent bridging. Experimental observations show that flow conditions correlate directly with the intensity of stirring. Mass flow in the metering container and hence optimum constancy of metering are attainable only from certain stirring efficiencies upwards. Cases of interference to metering due to poor flow of solids can be explained and overcome by modified dimensioning. The effects of the principal parameters - geometry and speed of rotation of the stirrer - are studied with the aid of two stirrer configurations - viz. overhead and concentric. Straightforward model calculations provide a mathematical method of estimation for optimum and reliable stirrer dimensioning also applicable to strongly cohesive solids.
    Additional Material: 22 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 851-858 
    ISSN: 0935-6304
    Keywords: High resolution gas chromatography ; Chlorinated hydrocarbons ; Polychlorinated biphenyls ; PCB indicator congeners ; Coelution ; Toxic PCB congeners ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Eighty one polychlorinated biphenyls (PCBs) and nineteen chlorinated pesticide standards have been analyzed on a newly developed apolar high resolution gas chromatography (HRGC) column. Emphasis was placed on the determination of PCB indicator congeners which are part of national regulations, and of toxic coplanar PCB congeners.The new column enables almost unambiguous quantification of the PCB indicator congeners (PCB 138 can be separated from both PCB 163 and PCB 164; PCB 28 and PCB 31 were also separated and no coelution was observed for PCB 52, PCB 118, and PCB 180). The new column furnished better results than CP-Sil 8 for the analysis of PCB indicator congeners in a sample of seal blubber.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...