GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Molecules, MDPI AG, Vol. 28, No. 1 ( 2022-12-22), p. 73-
    Abstract: A novel COVID-19 vaccine (BriLife®) has been developed by the Israel Institute for Biological Research (IIBR) to prevent the spread of the SARS-CoV-2 virus throughout the population in Israel. One of the components in the vaccine formulation is tris(hydroxymethyl)aminomethane (tromethamine, TRIS), a buffering agent. TRIS is a commonly used excipient in various approved parenteral medicinal products, including the mRNA COVID-19 vaccines produced by Pfizer/BioNtech and Moderna. TRIS is a hydrophilic basic compound that does not contain any chromophores/fluorophores and hence cannot be retained and detected by reverse-phase liquid chromatography (RPLC)-ultraviolet (UV)/fluorescence methods. Among the few extant methods for TRIS determination, all exhibit a lack of selectivity and/or sensitivity and require laborious sample treatment. In this study, LC–mass spectrometry (MS) with its inherent selectivity and sensitivity in the multiple reaction monitoring (MRM) mode was utilized, for the first time, as an alternative method for TRIS quantitation. Extensive validation of the developed method demonstrated suitable specificity, linearity, precision, accuracy and robustness over the investigated concentration range (1.2–4.8 mg/mL). Specifically, the R2 of the standard curve was 〉 0.999, the recovery was 〉 92%, and the coefficient of variance (%CV) was 〈 12% and 〈 6% for repeatability and intermediate precision, respectively. Moreover, the method was validated in accordance with strict Good Manufacturing Practice (GMP) guidelines. The developed method provides valuable tools that pharmaceutical companies can use for TRIS quantitation in vaccines and other pharmaceutical products.
    Type of Medium: Online Resource
    ISSN: 1420-3049
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2008644-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2017
    In:  Scientific Reports Vol. 7, No. 1 ( 2017-11-01)
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 7, No. 1 ( 2017-11-01)
    Abstract: Botulinum neurotoxins (BoNTs) are bacterial proteins that cause botulism, a life-threatening disease. The Endopep-MS assay permits rapid detection and serotypic differential diagnosis of BoNTs. The serotype-specific nature of this assay requires that each serum sample be aliquoted and individually tested, which in addition to the limited volume of clinical samples, especially in infants, points to the need for a multiplex assay. However, previous attempts to develop such an assay have been challenging, mainly due to inhibition of BoNT/A activity by the BoNT/E peptide substrate. BoNT/A and BoNT/E share the same native target protein as their substrate. We hypothesized that the steric interference between the BoNT/A and BoNT/E substrate peptides is responsible for the difficulty in simultaneously assaying these two toxins. To explore the basis for steric interference, we used the reported structure of BoNT/A in complex with SNAP-25 and modelled the structure of BoNT/E with SNAP-25. Following this thorough structural analysis, we designed a new peptide substrate for BoNT/A that maintained the assay sensitivity and allowed, for the first time, simultaneous detection of the three most abundant human botulinum serotypes. Adopting the multiplex assay will minimize the required sample volume and assay time for botulinum detection while maintaining the superior Endopep-MS assay performance.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2017
    detail.hit.zdb_id: 2615211-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...