GLORIA

GEOMAR Library Ocean Research Information Access

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Xiong, Enlai  (1)
  • Medizin  (1)
Materialart
Verlag/Herausgeber
Person/Organisation
Sprache
Erscheinungszeitraum
Fachgebiete(RVK)
  • Medizin  (1)
RVK
  • 1
    In: Cardiology, S. Karger AG, Vol. 147, No. 3 ( 2022), p. 290-297
    Kurzfassung: 〈 b 〉 〈 i 〉 Introduction: 〈 /i 〉 〈 /b 〉 The Amplatzer and Watchman left atrial appendage closure (LAAC) devices are the two most frequently used devices for LAAC devices worldwide. This meta-analysis aimed to compare the safety and efficacy of the two devices. 〈 b 〉 〈 i 〉 Methods: 〈 /i 〉 〈 /b 〉 We searched the PubMed, EMBASE, and the Cochrane Library for studies up to February 6, 2022 that compared the safety and efficacy of the Amplatzer and Watchman devices. 〈 b 〉 〈 i 〉 Results: 〈 /i 〉 〈 /b 〉 Fifteen studies including 2,150 patients in randomized controlled trials and 2,526 patients in observational studies were included in the meta-analysis. Amplatzer device was associated with higher rates of major procedure-related complications (odds ratio [OR]: 1.99, 95% confidence interval [CI] : 1.45–2.74, 〈 i 〉 p 〈 /i 〉 & #x3c; 0.0001) and device embolization (OR: 1.99, 95% CI: 1.09–3.64, 〈 i 〉 p 〈 /i 〉 = 0.03). However, Amplatzer device had lower rates of total peridevice leak (PDL) (OR: 0.48, 95% CI: 0.27–0.83, 〈 i 〉 p 〈 /i 〉 = 0.009), significant PDL (OR: 0.27, 95% CI: 0.12–0.57, 〈 i 〉 p 〈 /i 〉 = 0.0007) and device-related thrombus (DRT) (OR: 0.67, 95% CI: 0.48–0.95, 〈 i 〉 p 〈 /i 〉 = 0.02). No statistical differences were observed between the two devices in other safety and efficacy endpoints, such as pericardial effusion, cardiac tamponade, air embolism, vascular complications, ischemic stroke/transient ischemic attack (TIA), hemorrhagic stroke, all-cause death, cardiovascular death, and bleeding. 〈 b 〉 〈 i 〉 Conclusions: 〈 /i 〉 〈 /b 〉 Amplatzer LAAC device was associated with higher rates of major procedure-related complications, especially in device embolization. Watchman LAAC device was associated with higher rates of PDL and DRT. There were no significant differences between two devices in ischemic stroke/TIA, hemorrhagic stroke, all-cause death, cardiovascular death, and bleeding.
    Materialart: Online-Ressource
    ISSN: 0008-6312 , 1421-9751
    RVK:
    Sprache: Englisch
    Verlag: S. Karger AG
    Publikationsdatum: 2022
    ZDB Id: 1482041-9
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...