GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wu, Yaying  (5)
  • 1
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2022
    In:  Scientific Reports Vol. 12, No. 1 ( 2022-04-15)
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 12, No. 1 ( 2022-04-15)
    Abstract: This study aims to investigate the reliability and efficacy of rear 4-min Schirmer test, as a supplement indicator, in assessing tear secretion and diagnosing dry eye. 180 participants were enrolled in this study. Schirmer test I without anaesthesia was performed once on both eyes to determine the value of normal Schirmer test. The values of tear secretion were recorded at each minute. Other examinations included the following: the ocular surface disease index (OSDI), the standard patient evaluation of eye dryness (SPEED), fluorescein stain, tear film break-up time (BUT), and Meibomian gland (MG) secretion grading. The participants were divided into dry eye (DE) group and non-dry eye (ND) group. The values of the 2-min Schirmer test, rear 3-min Schirmer test, rear 4-min Schirmer test, and 5-min Schirmer test were 5.36 ± 4.63, 5.57 ± 2.11, 7.21 ± 4.13, and 10.93 ± 6.30, respectively, in the DE group. These indicators were 8.25 ± 6.80, 2.73 ± 2.31, 7.36 ± 3.42, and 11.84 ± 6.16, respectively, in the ND group. The rear 4-min Schirmer test had a significant correlation with OSDI and SPEED in the DE group (r =  − 0.242/ − 0.183) and in the ND group (r =  − 0.316/ − 0.373). Meanwhile, the rear 4-min Schirmer test had a stronger connection with fBUT (r = 0.159) and MG secretion (r =  − 0.162) in the DE group and also had higher accuracy in diagnosing severe DE and borderline DE. In conclusion, the rear 4-min Schirmer test may be a supplement indicator in assessing tear secretion and diagnosing DE.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2022
    detail.hit.zdb_id: 2615211-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Frontiers Media SA ; 2022
    In:  Frontiers in Medicine Vol. 9 ( 2022-4-26)
    In: Frontiers in Medicine, Frontiers Media SA, Vol. 9 ( 2022-4-26)
    Abstract: To investigate the effects of high-intensity use of smartphones on ocular surface homeostasis and to explore whether high-intensity use of handheld digital devices can cause false increase of dry eye diagnostic rate. Methods In this prospective self-control study, 60 subjects (120 eyes) were recruited and asked to read on smartphones provided by the same manufacturer for two consecutive hours. This study was conducted during 8:00 – 10:00 AM to eliminate the influence of digital equipment used the previous day. Ophthalmological examinations [non-invasive tear breakup time (NIBUT), fluorescein breakup time (FBUT), Schirmer I test, corneal fluorescein staining (CFS), bulbar conjunctival redness and meibomian gland (MG) assessment] and a questionnaire survey were conducted before and after the reading test. Based on the collected data, the changes in ocular surface damage and subjective symptoms of the subjects were evaluated, and the differences in the diagnostic rate of dry eye before and after high-intensity use of smartphones were compared. Results The diagnostic rate of dry eye was sharply increased (61.7% vs. 74.2%). The severity of dry eye also changed significantly, and the moderate and severe degree increased after reading (10% vs. 15%; 5% vs. 10.8%). The aggravated severity subjects had lower MG expressibility and more evident bulbar conjunctival redness compared to the non-aggravated severity subjects. After 2 h of continuous reading, NIBUT-First, NIBUT-Average and FBUT-Average were significantly decreased, while the proportion of BUT ≤ 5 s increased significantly. Non-invasive keratograph tear meniscus height(NIKTMH) decreased significantly compared to the baseline level, while the proportion of NIKTMH & lt;0.20 mm increased significantly. No significant difference was observed in the Schirmer I test and CFS score between the two groups. Compared to the baseline, evident aggravation was observed in bulbar conjunctival redness. The Ocular Surface Disease Index (OSDI) was significantly higher than the baseline after the reading test. Conclusion Diagnostic indicators related to dry eye are rapidly deteriorating after high-intensity smartphone use, especially those with lower MG expressibility and ocular redness. High-intensity smartphone use can increase the false positive rate of dry eye diagnosis by disturbing ocular surface homeostasis.
    Type of Medium: Online Resource
    ISSN: 2296-858X
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2022
    detail.hit.zdb_id: 2775999-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Frontiers Media SA ; 2022
    In:  Frontiers in Medicine Vol. 8 ( 2022-1-25)
    In: Frontiers in Medicine, Frontiers Media SA, Vol. 8 ( 2022-1-25)
    Abstract: Dry eye-related ocular surface examination is very important in the diagnosis and treatment of dry eye disease. With the recent advances in science and technology, dry eye examination techniques have progressed rapidly, which has greatly improved dry eye diagnoses and treatment. However, clinically, confusion remains about which examination to choose, how to ensure the repeatability of the examination, and how to accurately interpret the examination results. In this review, we systematically evaluate previous examinations of dry eye, analyze the latest views and research hotspots, and provide a reference for the diagnosis and management of dry eye.
    Type of Medium: Online Resource
    ISSN: 2296-858X
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2022
    detail.hit.zdb_id: 2775999-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Clinical and Translational Science, Wiley, Vol. 15, No. 4 ( 2022-04), p. 994-1002
    Abstract: This paper aims to investigate the efficacy of circularly polarized light smartphones in affecting dry eye symptoms and asthenopia through a comparison with linearly polarized smartphones. One hundred twenty participants were randomly divided into four groups. Dry eye and asthenopia symptoms were evaluated using the Ocular Surface Disease Index (OSDI), Computer Vision Syndrome Scale 17 (CVSS17), Convergence Insufficiency Symptom Survey (CISS), and visual analogue scale (VAS). Objective ocular examinations were assessed by confusion flicker frequency (CFF), tear meniscus height (TMH), noninvasive break‐up time (NIBUT), conjunctiva redness, fluorescein tear break‐up time (FTBUT), corneal fluorescein staining, and the Schirmer I test. Tests were performed before and after a reading task. Subjective evaluations including the OSDI, CVSS17, and CISS were all significantly increased after reading on a linearly polarized smartphone, whereas no change was observed in the circular polarization groups in both light and dark environments. A significantly enlarged VAS was shown in all of the four groups, but a significant increase in ΔVAS only appeared in the linear polarization groups. There were significant decreases in TMH, NIBUT, conjunctiva redness, FTBUT, and CFF after reading on a linearly polarized smartphone but the circularly polarized smartphone had lesser effects on these parameters. Our study indicated that reading on linearly polarized smartphones may cause dry eye disorder, asthenopia, and ocular discomforts, whereas circularly polarized smartphones appears to minimize these adverse effects on eye dryness and visual fatigue in light and dark environments.
    Type of Medium: Online Resource
    ISSN: 1752-8054 , 1752-8062
    URL: Issue
    Language: English
    Publisher: Wiley
    Publication Date: 2022
    detail.hit.zdb_id: 2433157-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Springer Science and Business Media LLC ; 2021
    In:  Scientific Reports Vol. 11, No. 1 ( 2021-06-01)
    In: Scientific Reports, Springer Science and Business Media LLC, Vol. 11, No. 1 ( 2021-06-01)
    Abstract: This study aims to investigate the reliability and efficacy of maximum fluorescein tear break-up time (FTBUTmax) in diagnosing dry eye disease (DED). 147 participants were enrolled in this study. Ocular symptoms were assessed by Ocular Surface Disease Index (OSDI). The fluorescein tear break-up time (FTBUT) examination, corneal fluorescein staining (CFS), and Schirmer I test were performed on both eyes. Each participant underwent 3 consecutive FTBUT tests, and five types of FTBUT values including FTBUTmax, the minimum FTBUT (FTBUTmin), the first FTBUT (FTBUT1), the average of three FTBUTs (FTBUT123) and the average of the first and second FTBUT (FTBUT12) were recorded. FTBUTmax was larger than the other FTBUT values, but no differences were found among the values of FTBUT1, FTBUT123, FTBUT12 and FTBUTmin. In the ROC analysis, FTBUTmax had the largest or the second largest area under the ROC (AUROC) in all three DED diagnostic criteria, while FTBUTmin had the least AUROC of them. ROC efficacy of FTBUTmax was significantly higher than that of FTBUT123, FTBUT12, FTBUT1 and FTBUTmin in the OSDI criteria and higher than that of FTBUT1 and FTBUTmin in Schirmer I test and CFS tests. FTBUTmax has a close correlation with OSDI, Schirmer I test and CFS, and is an effective tool for the DED diagnosis.
    Type of Medium: Online Resource
    ISSN: 2045-2322
    Language: English
    Publisher: Springer Science and Business Media LLC
    Publication Date: 2021
    detail.hit.zdb_id: 2615211-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...