GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Frontiers Media SA  (3)
  • Wang, Yunyan  (3)
Material
Publisher
  • Frontiers Media SA  (3)
Language
Years
  • 1
    In: Frontiers in Neurology, Frontiers Media SA, Vol. 13 ( 2022-5-31)
    Abstract: The purpose of this work was to summarize the real-world safety and efficacy of Pipeline Embolization Device (PED) therapy for small and medium-sized intracranial aneurysms in China. Methods Patients from the PED in China post-market multi-center registry study (PLUS) with aneurysms smaller than 12 mm were selected. Radiographic outcomes were assessed using digital subtraction angiography. Clinical outcomes included functional outcomes (modified Rankin Scale, MRS) in the early postoperative period ( ≤ 30 days) and early postoperative complications associated with PED therapy. Results A total of 652 patients with a combined 754 aneurysms were included in this study (mean age of 53.9 ± 10.3 years, 68.7% women). Mean aneurysm diameter was 6.78 ± 2.67 mm. Of the 687 stents deployed, 99.7% (685/689) were successfully deployed. In this study, 64.7% (488/754) of aneurysms were treated with only the PED, whereas 35.3% (266/754) were subjected to PED-assisted therapy. Radiographic outcome at the last follow-up (median time: seven months) was available for 64.3% (485/754) of the aneurysms. 82.5% (400/485) of aneurysms demonstrated complete occlusion (Raymond Roy Grade I). 81.4% (395/485) of aneurysms were found to meet the study's primary effectiveness outcome. At the early postoperative period, the mRS score was determined to be 0–2 vs. 3-6 in 98.2% (640/652) vs. 1.8% (12/652) of the cases, respectively. The combined major morbidity and mortality rate was 3.2% (21/652). Conclusion In the largest study of PED therapy for small and medium-sized intracranial aneurysms to date, pipeline-assisted coil embolization was chosen more often than multiple stent implantation for aneurysm treatment, demonstrating good results, high surgical success rates, high occlusion rates, and low morbidity and mortality. Clinical Trial Registration www.ClinicalTrials.gov , identifier: NCT03831672.
    Type of Medium: Online Resource
    ISSN: 1664-2295
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2022
    detail.hit.zdb_id: 2564214-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Frontiers in Neurology, Frontiers Media SA, Vol. 12 ( 2021-9-16)
    Abstract: Background and Purpose: The utilization of flow diversion for ruptured intracerebral aneurysms (IAs) is still limited. We aimed to demonstrate our multicenter experience using the pipeline embolization device (PED) for ruptured IAs that were difficult to treat by clipping and coiling. Methods: Thirty-eight patients with ruptured IAs who underwent PED treatment from 2015 to 2020 were retrospectively reviewed. Factors associated with procedure-related stroke (ischemic and hemorrhagic) and clinical and angiography outcomes were analyzed. Results: There were 14 (36.8%) saccular IAs, 12 (31.6%) blister-like IAs, and 12 (31.6%) dissecting IAs. Perforator involvement was noted in 10 (26.3%) IAs. Early PED placement ( ≤ 15 days) and adjunctive coiling treatment were performed in 27 (71.1%) and 22 (57.9%) cases, respectively. The overall rate of stroke-related complications was 31.6% (12/38) (including rates of 10.5% for procedure-related hemorrhagic complications and 15.8% for procedure-related infarction). The mortality rate was 13.2% (5/38), and 84.2% of patients (32/38) had favorable outcomes. Thirty-two (84.2%) patients underwent follow-up angiographic evaluations; of these, 84.4% (27 patients) had complete occlusion and 15.6% had incomplete obliteration. Multivariate analysis revealed that early PED placement was not associated with a high risk of procedure-related stroke or an unfavorable outcome. Adjunctive coiling exhibited an association with procedure-related stroke ( p = 0.073). Procedure-related hemorrhagic complications were significantly associated with an unfavorable outcome ( p = 0.003). Immediate contrast stasis in the venous phase was associated with complete occlusion during follow-up ( p = 0.050). Conclusion: The PED is a feasible and effective treatment to prevent rebleeding and achieve aneurysm occlusion, but it is associated with a substantial risk of periprocedural hemorrhage and ischemic complications in acute ruptured IAs. Therefore, the PED should be used selectively for acutely ruptured IAs. Additionally, adjunctive coiling might increase procedure-related stroke; however, it may reduce aneurysm rebleeding in acutely ruptured IAs. Patients with immediate contrast stasis in the venous phase were more likely to achieve total occlusion. A prospective study with a larger sample size should be performed to verify our results.
    Type of Medium: Online Resource
    ISSN: 1664-2295
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2021
    detail.hit.zdb_id: 2564214-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Frontiers in Aging Neuroscience, Frontiers Media SA, Vol. 14 ( 2022-6-13)
    Abstract: The Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial primarily demonstrated the safety and efficacy of the implantation of multiple pipeline embolization devices (multi-PEDs) for large/giant intracranial aneurysms. However, no study has focused on when, why, or how to apply multi-PEDs. Objective The purpose of this study was to investigate the indications and strategies of using multi-PEDs for complex intracranial aneurysms. Methods Patients who had been treated with two or more PEDs were included in the post-market multicenter registry study from 2014 to 2019, across 14 centers in China. Indications, strategies, perioperative safety, and clinical outcomes were retrospectively analyzed. The modified Rankin scale (mRS) score was used to evaluate clinical outcomes comprehensively, and the O’Kelly–Marotta (OKM) grading scale was used to evaluate aneurysm healing results. Results A total of 55 intracranial aneurysms were treated with multi-PEDs. There were 20 fusiform aneurysms with a large range, 25 large/giant saccular aneurysms, six aneurysms with failed treatment, and four aneurysms with greatly varied diameters of the parent artery. The strategies included telescope techniques in 40 patients and overlap techniques in 15 patients. In total, 120 stents were deployed in 55 patients. The operation styles included 25 patients (55.6%) with two PEDs, 21 patients (38.2%) with two PEDs combined with coiling, four patients (7.3%) with three PEDs, four patients (7.3%) with three PEDs combined with coiling, and one patient (1.8%) with four PEDs. Angiography revealed OKM D in two, OKM C in seven, and OKM A and B in 46 cases after surgery. During the perioperative period, eight patients developed neurological dysfunction, three of whom died. A total of thirty-four patients were followed up with digital subtraction angiography for 2–45 (8.2 ± 8.0) months. Angiography revealed OKM D in 26, OKM C in five, and OKM B in three. At the last follow-up, the mRS score was 0–1 in 52 patients. Conclusion The treatment of anterior circulation aneurysms with multi-PEDs is safe and effective. The implantation of multi-PEDs could be considered for large-scale fusiform aneurysms, large/giant saccular aneurysms with a jet-sign, salvage of failed PED treatments, and in cases where the diameter of the parent artery varies greatly.
    Type of Medium: Online Resource
    ISSN: 1663-4365
    Language: Unknown
    Publisher: Frontiers Media SA
    Publication Date: 2022
    detail.hit.zdb_id: 2558898-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...