    In: Materials, MDPI AG, Vol. 16, No. 3 ( 2023-01-25), p. 1052-
    Abstract: During underground space exploitation in the urbanization process, numerous foundation pits were constructed where a diaphragm wall was often used as a retaining structure and waterproof curtain. Due to complicated engineering geological conditions or improper construction, diaphragm walls and wall joints often exhibit quality defects. Groundwater leaked from these quality defects to foundation pits during excavation, endangering the safety of the pit and surrounding facilities. The current leakage identification of the underground retaining structure was performed by artificial visual detection, which cannot satisfy the engineering requirement. The temperature field in the leakage area of the diaphragm wall was different from other areas. The leakage wall imaging system using a thermal imager was efficient in visualizing leaking, which was not visible to the naked eye. In this study, infrared thermal imaging technology was introduced in potential leakage detection for the diaphragm wall of a foundation pit. The infrared radiation characteristics of the diaphragm wall leakage and the potential leakage parts were studied through laboratory simulation tests and on-site detection methods. The maximum temperature appeared at the water outlet and the surface of the defect with hidden defect, and the temperature field was symmetrically distributed along the cross-section direction. In the potential leakage area, the temperature difference at the penetration point was 23.4 °C when the initial water pressure was 10 kPa. The temperature difference at the penetration point was 21.8 °C when the initial water pressure was 30 kPa. In the field test, the maximum temperature difference between the leakage area and the surrounding wall was 4.5 °C. The study can provide a reference for similar engineering.
    Type of Medium: Online Resource
    ISSN: 1996-1944
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2487261-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Materials, MDPI AG, Vol. 16, No. 2 ( 2023-01-06), p. 561-
    Abstract: Leakage in the diaphragm wall is difficult to detect in deep foundation pits. In this study, the conceptual model of active and passive thermal leak detection methods was proposed according to the occurrence of temperature field anomalies caused by seepage. Experiments were performed using a heating system and an optical fiber temperature measurement system to verify the thermal leakage detection systems. Numerical simulations were performed to understand the mechanism of the detecting method. Results indicated that the optical cable could detect the low-temperature anomaly in the active temperature field leak detection. The arrangement method of the leakage detection system was also presented in actual engineering.
    Type of Medium: Online Resource
    ISSN: 1996-1944
    Language: English
    Publisher: MDPI AG
    Publication Date: 2023
    detail.hit.zdb_id: 2487261-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...