GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2022
    In:  European Heart Journal Vol. 43, No. Supplement_2 ( 2022-10-03)
    In: European Heart Journal, Oxford University Press (OUP), Vol. 43, No. Supplement_2 ( 2022-10-03)
    Abstract: Atrial Fibrillation (AF) is associated with an increased risk of stroke that can be mitigated with anticoagulation therapy. Opportunistic screening for AF for primary stroke prevention is recommended in subjects above 65. However, the paroxysmal and asymptomatic nature of AF hampers early detection with a single time point screening. Multiple time point measurements are superior to single time point measurements for the detection of AF. New technologies such as photoplethysmography (PPG) enable large scale AF screening with repetitive measurements at low-cost using only a smartphone. Purpose To explore an entirely online AF screening program in subjects with an elevated stroke risk. Methods The Belgian Heart Rhythm Association launched a digital marketing campaign, to promote AF screening during “The Belgian Week of the Heart Rhythm”. Candidates were referred to an online questionnaire to calculate their CHADS-VASC score. Subjects older than 18 with a CHADS-VASC score of 2 or more were allowed to enter the screening program. AF screening was performed with a PPG-based smartphone application. A 60-second PPG trace is captured by placing a fingertip on the smartphone's camera. The smartphone application analyses the PPG trace with an artificial intelligence software. Subjects were instructed to perform measurement twice daily and while experiencing symptoms over the course of 7 days. Measurements were classified as AF or non-AF by the algorithm and were reviewed by medical technicians. Results Of the 12.602 candidates who completed the questionnaire, 6.020 subjects met the inclusion criteria and were offered screening. However, only 2.111 (35%) participated in the screening program. The mean age of participants was 63±11 years, 37.3% was male, median CHADS-VASC was 2 (2–3). 257 participants (12.2%) were previously known with AF. In total 25.362 PPG recordings of 60 seconds were performed of which 258 demonstrated AF. AF was detected in 56 participants (2.7%). This was a new finding in 36 participants (1.7%) meaning that 64.3% of participants demonstrating AF were not previously known with AF. The number needed to screen was 58.6 to detect AF in a population without a history of AF and the number needed to invite was 167.2. Only 20 participants (7.8%) with a history of AF demonstrated AF during the screening program. Conclusions AF screening in subjects with an elevated stroke risk is feasible with an entirely online screening program without the need for medical hardware or medical personnel with an acceptable number needed to screen. However, this approach failed to target subjects in the highest age groups and since almost two thirds of the subjects interested in the screening program failed to commence screening, approaches to increase this response (specifically in high-risk groups) needs to be explored. Funding Acknowledgement Type of funding sources: None.
    Type of Medium: Online Resource
    ISSN: 0195-668X , 1522-9645
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2022
    detail.hit.zdb_id: 2001908-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: European Heart Journal, Oxford University Press (OUP), Vol. 40, No. Supplement_1 ( 2019-10-01)
    Abstract: Time delay between onset of symptoms and seeking medical attention is a major determinant of mortality and morbidity in patients with acute coronary artery occlusion (ACAO). Response time might be reduced by reliable self-detection of ACAO. Currently no self-applicable device can accurately detect ACAO. We have recently shown that an automatic algorithm based upon a three lead system (RELF method) accurately detects ACAO. Purpose In this multicenter observational study we tested the operational feasibility, sensitivity and specificity of our RELF method, built into a mobile handheld device, for detection of ACAO. Methods Patients with planned elective percutaneous coronary intervention (PCI), who were able to use a smartphone, were asked to perform random ambulatory self-recordings for at least one week. A similar self-recording was made before angioplasty and at 60 s of balloon occlusion. Results The operational feasibility of ambulatory self-recordings in enrolled patients with CAD was 59/64 (92.1%, 95% CI: 83.0–96.6). Of all self-recordings 91.1% (n=4567) were automatically classified as successful within one minute. The mean false positive rate during daily life conditions was 4.19% (95% CI: 3.29–5.10). Amongst 65 balloon occlusions, 63 index-tests at 60 s of occlusion were available. The sensitivity for the target conditions “ACAO”, “ACAO with ECG changes” and “ACAO with ECG changes and ST segment elevation myocardial infarction (STEMI) criteria” was respectively 55/63 (0.87; 95% CI: 0.77–0.93), 54/57 (0.95; 95% CI: 0.86–0.98) and 35/35 (1.00). The figure depicts all (n=3936) ST difference vector (STDVn) measurements obtained during ambulatory postural changes, exercise and coronary artery occlusion with and without ECG changes and/or STEMI criteria. Receiver Operator Curve (ROC) for ACAO at different cut-off values of the magnitude of STDVn was 0.973 (95% CI: 0.956–0.990). Boxplots of all STDVn test recordings Conclusions Self-recording with our RELF device is feasible for the majority of patients with CAD. The sensitivity and specificity for automatic detection of the earliest phase of acute coronary artery occlusion support the concept of our RELF device for patient empowerment to reduce delay and increase survival without overloading emergency services. This is the first clinical study that confirms the proof-of-concept of self-detection of acute coronary artery occlusion in outpatients with CAD. Acknowledgement/Funding Ghent University, Industrial Research Fund (IOF reference: F2015/IOF-advanced/084).
    Type of Medium: Online Resource
    ISSN: 0195-668X , 1522-9645
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2019
    detail.hit.zdb_id: 2001908-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: EP Europace, Oxford University Press (OUP), Vol. 22, No. 8 ( 2020-08-01), p. 1189-1196
    Abstract: The relation between atrial tachyarrhythmia (ATA) burden in paroxysmal atrial fibrillation (AF), atrial remodelling, and efficacy of catheter ablation (CA) is unknown. We investigated whether high vs. low-burden paroxysmal AF patients have distinct clinical characteristics or electro-mechanical properties of the left atrium (LA) and whether burden impacts outcome of CA. Methods and results Atrial tachyarrhythmia burden, defined as the percentage of time spent in ATA, was assessed by insertable cardiac monitors in 105 patients before and after CA. Clinical characteristics and electro-mechanical properties of LA were compared between patients with high vs. low ATA burden. Catheter ablation efficacy was assessed by reduction in ATA burden and 1-year freedom from any ATA. Median ATA burden was 2.7% (highest tertile 9.3%). Clinical characteristics and electrical properties of LA (refractoriness, conduction velocity, low voltage) did not differ between high (≥9.3%) vs. low ATA burden ( & lt;9.3%) patients. High ATA burden patients had larger LA diameter (46.5 ± 6 vs. 42.5 ± 6mm, P  & lt; 0.01), volume (93.8 ± 22 vs. 80.4 ± 21mL, P = 0.01), and lower LA reservoir and contractile strain (19.7 ± 6 vs. 24.7 ± 6%, P  & lt; 0.01; 10.3 ± 3 vs. 12.8 ± 4%, P = 0.01). Catheter ablation reduced ATA burden by 100% (100–100) in both groups (P = 1.0). Freedom from ATA after CA was equally high (83% vs. 89%, P = 0.38). Conclusion Paroxysmal AF patients with high ATA burden have altered LA mechanical properties, reflected by larger size and impaired function. Despite mechanical remodelling of the atria, they are excellent responders to CA. Most likely the lack of fibrosis and/or advanced electrical remodelling explain why pulmonary veins remain the dominant trigger for AF in this patient cohort.
    Type of Medium: Online Resource
    ISSN: 1099-5129 , 1532-2092
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2020
    detail.hit.zdb_id: 2002579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Clinical Chemistry, Oxford University Press (OUP), Vol. 38, No. 11 ( 1992-11-01), p. 2261-2266
    Abstract: To determine possible associations between lipoprotein(a) [Lp(a)] and the severity of coronary artery lesions, we measured lipid, apolipoprotein, and Lp(a) in a large population of Belgian patients (n = 1054) undergoing coronary angiography. In both women and men, univariate analysis demonstrated significant differences in the Lp(a) concentrations according to the severity of the coronary stenosis. However, after adjustment for possible confounding factors, many of these differences were attenuated, indicating that other variables that differentiate patients from control subjects also influence Lp(a) distribution. Differences in lipid, apolipoprotein, and Lp(a) concentrations between male and female patients are discussed.
    Type of Medium: Online Resource
    ISSN: 0009-9147 , 1530-8561
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 1992
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2018
    In:  EP Europace Vol. 20, No. suppl_1 ( 2018-03-01), p. i162-i162
    In: EP Europace, Oxford University Press (OUP), Vol. 20, No. suppl_1 ( 2018-03-01), p. i162-i162
    Type of Medium: Online Resource
    ISSN: 1099-5129 , 1532-2092
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2002579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: EP Europace, Oxford University Press (OUP), Vol. 20, No. suppl_1 ( 2018-03-01), p. i158-i158
    Type of Medium: Online Resource
    ISSN: 1099-5129 , 1532-2092
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2002579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    In: EP Europace, Oxford University Press (OUP), Vol. 20, No. suppl_1 ( 2018-03-01), p. i220-i220
    Type of Medium: Online Resource
    ISSN: 1099-5129 , 1532-2092
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2002579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    In: EP Europace, Oxford University Press (OUP), Vol. 20, No. suppl_1 ( 2018-03-01), p. i242-i242
    Type of Medium: Online Resource
    ISSN: 1099-5129 , 1532-2092
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2018
    detail.hit.zdb_id: 2002579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Online Resource
    Online Resource
    Oxford University Press (OUP) ; 2020
    In:  European Heart Journal Vol. 41, No. Supplement_2 ( 2020-11-01)
    In: European Heart Journal, Oxford University Press (OUP), Vol. 41, No. Supplement_2 ( 2020-11-01)
    Abstract: In Belgium ICD implantation is restricted to 23 centers. A previous analysis of our group based on aggregated results per center showed that 3y mortality varied significantly between centers ranging from 7.5 to 23.4%. Multivariate analysis demonstrated that volume, infection rate and a higher proportion of implantations in primary prevention were predictors of 3y-mortality. These findings needed to be confirmed on a patient level since they could be caused by inter-patient rather than inter-hospital differences. Methods The QERMID-ICD database is a retrospective database of all patients implanted with an ICD in Belgium managed by the governmental health care institution (RIZIV/INAMI). Participation is mandatory for reimbursement. We analyzed data of 9896 new implantations performed between 2010 and 2016. Following patient characteristics were available: demographics (gender, NYHA class, primary vs secondary prevention, underlying heart disease, type of device, QRS duration, age and ejection fraction (EF)), comorbidities (atrial fibrillation, diabetes, COPD, neurological disease, oncological disease and renal failure), volume of center (low & lt; median of 65 primo-implantations/year vs high & gt;65 implantations/year) and the average income of the arrondissement in which the patient lived (low income & lt; p25, median p25-p75, high & gt; p75). The primary endpoint was 3y-mortality. Chi-squared test and Mann-Whitney U test with correction for multiple testing were used and multivariate logistic regression was performed to determine the corrected odds ratio for 3-year mortality. Finally, Kaplan-Meier survival analysis was performed. Results Low volume centers treated different patients than high volume centers. They implant more primary prevention (66.5 vs. 61.6%), more often patients with ischemic cardiomyopathy (49.8 vs 47.9%), less often arrhythmogenic heart disease (13.2 vs 16.6%) and patients with more co-morbidities and from communities with lower average income. High volume centers used more cardiac resynchronization therapy (26.8 vs 22.5%) despite no difference in QRS width. 1 and 3-y mortality were significantly higher in the low volume centers, respectively 5.6 vs. 4.4% and 16 vs. 11.1%. This was also confirmed in Kaplan Meier survival analysis. In multivariate logistic regression underlying heart disease, income, age, EF, NYHA class, CRT, indication and most comorbidities were significantly associated with mortality, but center volume remained an independent risk factor for 3-y mortality (OR = 0.749 (0.702–0.937), p & lt;0.001). Conclusion Patients treated in low and high-volume centers in Belgium are different. However, there remained an association between volume and mortality of centers when controlling for these differences. Further research to elucidate if this association is due to statistical limitations of our analysis, referral bias or differences in quality of care is necessary. Funding Acknowledgement Type of funding source: None
    Type of Medium: Online Resource
    ISSN: 0195-668X , 1522-9645
    Language: English
    Publisher: Oxford University Press (OUP)
    Publication Date: 2020
    detail.hit.zdb_id: 2001908-7
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Online Resource
    Online Resource
    The American Association of Immunologists ; 1991
    In:  The Journal of Immunology Vol. 147, No. 4 ( 1991-08-15), p. 1180-1188
    In: The Journal of Immunology, The American Association of Immunologists, Vol. 147, No. 4 ( 1991-08-15), p. 1180-1188
    Abstract: CD4+ TCR-gamma delta+ T cells comprise a very small subset of TCR-gamma delta+ T cells. CD4+ TCR gamma delta+ T cell clones were established to study the phenotypical and functional characteristics of these cells. Thirty-four CD4+ TCR-gamma delta+ T cell clones were established after sorting CD4+ T cells from a pre-expanded TCR-gamma delta+ T cell population. These clones as well as the CD4- TCR-gamma delta+ T cells from the same donor used V gamma 2 and V delta 2. In a second cloning experiment CD4+ TCR-gamma delta+ T cells were cloned directly from freshly isolated TCR-gamma delta+ T cells using a cloning device coupled to a FACS sorter. Forty-three clones were obtained, which all expressed CD4 and TCR-gamma delta. Eleven of these clones used V delta 1 and three of them coexpressed V gamma 2. The other CD4+ TCR-gamma delta+ T cell clones used both V delta 2 and V gamma 2. CD4+ TCR-gamma delta+ T cell clones expressed CD28 irrespective of the V gamma or V delta usage, and were CD11b negative. Three CD4-CD8+ TCR-gamma delta+ clones expressed CD8 alpha but not CD8 beta and were CD11b positive. CD28 expression among CD4-CD8+ and CD4-CD8- was variable but lower than on CD4+ T cell clones. CD4- TCR-gamma delta+ T cell clones using V gamma 2 and V delta 2 specifically lyse the Burkitt lymphoma cell line Daudi and secrete low levels of IFN-gamma and granulocyte-macrophage-CSF upon stimulation with Daudi. In contrast, most CD4+ T cell clones that use V gamma 2 and V delta 2 had a very low lytic activity against Daudi cells and secrete high levels of IFN-gamma and granulocyte-macrophage-CSF after stimulation with Daudi cells. The NK-sensitive cell line K562 was killed efficiently by the CD4- TCR-gamma delta+ T cell clones, but not by CD4+ TCR-gamma delta+ T cell clones, and could not induce cytokine secretion in CD4+ or CD4- T cell clones. CD4+ TCR-gamma delta+ T cell clones, but not the CD4- clones, could provide bystander cognate T cell help for production of IgG, IgM, and IgA in the presence of IL-2 and IgE in the presence of IL-4. Thus, CD4+ TCR-gamma delta+ T cells are similar to CD4+ TCR-alpha beta+ T cells in their abilities to secrete high levels of cytokines and to provide T cell help in antibody production.(ABSTRACT TRUNCATED AT 400 WORDS)
    Type of Medium: Online Resource
    ISSN: 0022-1767 , 1550-6606
    RVK:
    RVK:
    Language: English
    Publisher: The American Association of Immunologists
    Publication Date: 1991
    detail.hit.zdb_id: 1475085-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...