GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Emergency Medicine Journal, BMJ
    Abstract: During closed reduction of displaced distal radius fractures, physical examination is used to determine the need for further manipulation before radiographic confirmation and cast application. Manipulation performed under ultrasound guidance has the potential to decrease the number of reduction attempts. Methods This multicentre randomised controlled trial was undertaken between December 2018 and July 2020 in the ED of four hospitals in the Netherlands. Patients aged ≥16 years presenting to the ED with a distal radius fracture requiring closed reduction were randomised to either point-of-care ultrasound (PoCUS)-guided or standard reduction. The primary outcome was the proportion of patients requiring more than one reduction attempt. The secondary outcomes were time to complete reduction and treatment plan at ED discharge (conservative or operative repair). Results A total of 214 patients were screened, of which 211 patients were included for primary endpoint analysis (87% female, median age 68 years, 94% dorsal angulation, 59% intra-articular and 73% multifragmentary). In total, 105 patients were randomised to standard treatment and 106 patients to PoCUS-guided fracture reduction. In the standard treatment group, 13 patients (12%) required more than one reduction attempt, compared with 6 patients (6%) in the PoCUS group (OR 2.35, 95% CI 0.86 to 6.45). The median reduction time was 5 min in the PoCUS group (IQR 3–6) vs 3 min (IQR 2–4) in the standard reduction group (p 〈 0.001). At ED discharge, operative repair was indicated for 17 (16%) patients in the standard group and 21 (20%) patients in the PoCUS group (OR 0.78, 95% CI 0.39 to 1.58). Conclusion This study could not demonstrate that PoCUS-guided reduction of distal radius fractures was associated with a statistically significant decrease in the number of reduction attempts. Trial registration number The Netherlands Trial Register (NTR7934).
    Type of Medium: Online Resource
    ISSN: 1472-0205 , 1472-0213
    Language: English
    Publisher: BMJ
    Publication Date: 2023
    detail.hit.zdb_id: 2027092-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: BMJ Open, BMJ, Vol. 12, No. 9 ( 2022-09), p. e059848-
    Abstract: Previous studies show that prolonged exposure to a high inspired oxygen concentration (FiO 2 ) is associated with unfavourable haemodynamic effects. Until now, it is unknown if similar effects also occur after oxygen therapy of limited duration in the emergency department (ED). Objectives To investigate the haemodynamic effects of a high FiO 2 administered for a limited duration of time in patients who receive preoxygenation for procedural sedation and analgesia (PSA) in the ED. Design, settings and participants In a prospective cohort study, cardiac output (CO), stroke volume (SV) and systemic vascular resistance (SVR) were measured using the Clearsight non-invasive CO monitoring system in patients who received preoxygenation for PSA in the ED. Measurements were performed at baseline, after 5 min of preoxygenation via a non-rebreathing mask at 15 /L min and after 5 min of flush rate oxygen administration. Outcomes measures The primary outcome was defined as the change in CO (L/min) from baseline after subsequent preoxygenation with 15 L/min and flush rate. Results Sixty patients were included. Mean CO at baseline was 6.5 (6.0–6.9) L/min and decreased to 6.3 (5.8–6.8) L/min after 5 min of oxygen administration at a rate of 15 L/min, and to 6.2 (5.7–6.70) L/min after another 5 min at flush rate (p=0.037). Mean SV remained relatively constant during this period, whereas mean SVR increased markedly (from 781 (649–1067), to 1244 (936–1695) to 1337 (988–1738) dyn/s/cm –5 , p 〈 0.001. Sixteen (27%) patients experienced a 〉 10% decrease in CO. Conclusion Exposure of patients to a high FiO 2 for 5–10 min results in a significant drop in CO in one out of four patients. Therefore, even in the ED and in prehospital care, where oxygen is administered for a limited amount of time, FiO 2 should be titrated based on deficit whenever this is feasible and high flow oxygen should not be given as a routine treatment.
    Type of Medium: Online Resource
    ISSN: 2044-6055 , 2044-6055
    Language: English
    Publisher: BMJ
    Publication Date: 2022
    detail.hit.zdb_id: 2599832-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: European Journal of Emergency Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 28, No. 3 ( 2021-06), p. 202-209
    Abstract: Healthcare personnel working in the emergency department (ED) is at risk of acquiring severe acute respiratory syndrome coronavirus-2 (SARS-Cov-2). So far, it is unknown if the reported variety in infection rates among healthcare personnel is related to the use of personal protective equipment (PPE) or other factors. Objective The aim of this study was to investigate the association between PPE use and SARS-CoV-2 infections among ED personnel in the Netherlands. Design, setting and participants A nationwide survey, consisting of 42 questions about PPE-usage, ED layout - and workflow and SARS-CoV-2 infection rates of permanent ED staff, was sent to members of the Dutch Society of Emergency Physicians. Members were asked to fill out one survey on behalf of the ED of their hospital. The association between PPE use and the infection rate was investigated using univariable and multivariable regression analyses, adjusting for potential confounders. Outcome measures Primary outcome was the incidence of confirmed SARS-CoV-2 infections among permanent ED staff between 1 March and 15 May 2020. Results Surveys were sent to 64 EDs of which 45 responded (70.3%). In total, 164 ED staff workers [5.1 (3.2–7.0)%] tested positive for COVID-19 during the study period compared to 0.087% of the general population. There was significant clustering of infected ED staff in some hospitals (range: 0–23 infection). In 13 hospitals, an FFP2 (filtering facepiece particles 〉 94% aerosol filtration) mask or equivalent and eye protection was worn for all contacts with patients with suspected or confirmed SARS-CoV-2 during the whole study period. The unadjusted staff infection rate was higher in these hospitals [7.3 (3.4–11.1) vs. 4.0 (1.9–6.1)%, absolute difference + 3.3%] . Hospital staff testing policy was identified as a potential confounder of the relation between PPE use and confirmed SARS-CoV-2 infections (collinearity statistic 0.95). After adjusting for hospital testing policy, type of PPE was not associated with incidence of COVID 19 infections among ED staff ( P  = 0.40). Conclusion In this cross-sectional study, the use of high-level PPE (FFP2 or equivalent and eye protection) by ED personnel during all contacts with patients with suspected or confirmed SARS-CoV-2 does not seem to be associated with a lower infection rate of ED staff compared to lower level PPE use. Attention should be paid to ED layout and social distancing to prevent cross-contamination of ED personnel.
    Type of Medium: Online Resource
    ISSN: 0969-9546
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2028878-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2021
    In:  European Journal of Emergency Medicine Vol. 28, No. 1 ( 2021-1), p. 77-78
    In: European Journal of Emergency Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 28, No. 1 ( 2021-1), p. 77-78
    Type of Medium: Online Resource
    ISSN: 0969-9546
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2028878-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...