    In: The Journal of Vascular Access, SAGE Publications, Vol. 22, No. 1 ( 2021-01), p. 75-80
    Abstract: The important effect of regular blood flow surveillance on arteriovenous fistula maintenance is emphasized. The ultrasonic dilution technique for blood flow surveillance can be performed during hemodialysis, but there are some limitations. Blood flow is traditionally measured by duplex Doppler ultrasound during the nondialysis period. However, the surveillance workload for arteriovenous fistula has increased with the rapid increase in the hemodialysis population size. Efficient methods for blood flow surveillance during hemodialysis are needed. Methods: Eighty-four hemodialysis patients with a forearm radiocephalic arteriovenous fistula were enrolled in this cross-sectional study. Each received blood flow measurements using ultrasonic dilution technique and duplex Doppler ultrasound during hemodialysis. Duplex Doppler ultrasound measurements included the blood flow of the brachial artery and radial artery. The correlations between these variables were analyzed. Results: The correlation coefficients ( r) between flow measured by ultrasonic dilution technique and brachial artery flow measured by duplex Doppler ultrasound, between flow measured by ultrasonic dilution technique and radial artery flow measured by duplex Doppler ultrasound, and between brachial artery flow and radial artery flow measured by duplex Doppler ultrasound were 0.724, 0.784, and 0.749, respectively (all p 〈 0.001). Conclusion: Blood flow measured by ultrasonic dilution technique was positively correlated with blood flow measured by duplex Doppler ultrasound during hemodialysis, suggesting that duplex Doppler ultrasound can be used to monitor the trends in the blood flow of the brachial artery and radial artery for timely intervention to improve patency during hemodialysis.
    Type of Medium: Online Resource
    ISSN: 1129-7298 , 1724-6032
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2021
    detail.hit.zdb_id: 2079292-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: The Journal of Vascular Access, SAGE Publications, Vol. 21, No. 5 ( 2020-09), p. 602-608
    Abstract: Patients with arteriovenous fistulas are advised to avoid carrying heavy objects draped over the fistula arm. Awareness gradually leads to overprotection and a reduction in the use of the fistula arm. However, restricting motion in the fistula arm leads to decreased quality of life and diminished muscle strength. The current safety recommendations regarding lifting heavy items with the fistula arm are primarily based on experience. Few studies have provided evidence clarifying the scope of safe activity and the influence of load bearing on the continued patency of arteriovenous fistulas. Methods: This prospective observation was based on a long-term follow-up study in which 86 hemodialysis recipients with arteriovenous fistulas were randomized into either a dumbbell group or a handgrip group. The dumbbell group exercised with 6-lb dumbbells, while the handgrip group squeezed rubber balls. Postintervention primary patency and adverse events at the 6-month follow-up were analyzed. Results: No significant difference in postintervention primary patency was observed between the dumbbell group and the handgrip group at 6 months (97.4% vs 95.0%). There were two participants with high-flow fistulas in the dumbbell group and three in the handgrip group, with no significant difference between the two groups (5.3% vs 7.5%). In both groups, there were no other adverse events reported regarding cardiac failure, aneurysm, puncture site hematoma, or hemorrhage. Conclusion: Hemodialysis patients can safely use their fistula arm to lift objects weighing less than 6 lb, which encourages increased motion and helps preserve the functionality of the fistula arm.
    Type of Medium: Online Resource
    ISSN: 1129-7298 , 1724-6032
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 2079292-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: The Journal of Vascular Access, SAGE Publications, Vol. 21, No. 6 ( 2020-11), p. 938-944
    Abstract: Prepump arterial pressure (Pa) indicates the ease or difficulty with which the blood pump can draw blood from vascular access (inflow) during hemodialysis. The absolute prepump arterial pressure to blood pump speed (Qb) ratio (|Pa/Qb|) may reflect the dysfunction of other vascular accesses. There is no consensus on the impact of |Pa/Qb| on arteriovenous fistula dysfunction. This study aimed to demonstrate the impact of |Pa/Qb| on arteriovenous fistula dysfunction. Methods: In this retrospective analysis, 490 hemodialysis patients with arteriovenous fistula from three hospitals were enrolled. Data were extracted from the I-Diapro database and hospital case systems. The absolute values for |Pa/Qb| and other data collected in the first month of enrollment were used to predict arteriovenous fistula dysfunction and determine the |Pa/Qb| cutoff value. Based on this value, patients were grouped, and 1-year arteriovenous fistula function was analyzed. Patients were followed until arteriovenous fistula dysfunction, until access type replacement, or for 12 months. Results: The area under the receiver operating characteristic curve for fistula dysfunction over 1 year was 0.65, with an optimal |Pa/Qb| value, sensitivity, and specificity of 0.499, 60.7%, and 72.6%, respectively. |Pa/Qb|  〉  0.499 was associated with earlier intervention (317.37 ± 7.68 vs 345.96 ± 3.64 days), lower survival ( p  〈  0.001), and a 3.26-fold greater risk of arteriovenous fistula dysfunction ( p  〈  0.001) than |Pa/Qb| ⩽ 0.499. Conclusions: |Pa/Qb| was an independent risk factor for arteriovenous fistula dysfunction. Nurses should emphasize |Pa/Qb| monitoring and properly set blood pump speed according to this ratio to protect arteriovenous fistula function. |Pa/Qb|  〉  0.499 might be a predictive measure of arteriovenous fistula dysfunction.
    Type of Medium: Online Resource
    ISSN: 1129-7298 , 1724-6032
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 2079292-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Journal of Biomaterials Applications, SAGE Publications, Vol. 30, No. 2 ( 2015-08), p. 133-146
    Abstract: The aim of this work was to develop long-term radiopaque microspheres (LRMs) by entrapping lipiodol in biocompatible polyvinyl alcohol with multiple emulsions chemical crosslinking method. The high content of lipiodol (0.366 g/mL) was hardly released from LRMs in vitro and the radiopacity could maintain at least 3 months after subcutaneous injection in mice without weakening. A series of tests was performed to evaluate the feasibility of LRMs for embolization. LRMs were proved to be smooth, spherical, and well dispersed with diameter range of 100–1200 μm. Young's modulus of LRMs was 55.39 ± 9.10 kPa and LRMs could be easily delivered through catheter without aggregating or clogging. No toxicity of LRMs was found to mouse L929 fibroblasts cells and only moderate inflammatory in surrounding tissue of mice was found after subcutaneous injection of LRMs. After LRMs were embolized in renal artery of a rabbit, the distribution and radiopacity of LRMs in vivo were easily detectable by X-ray fluoroscopy and computed tomography (CT) imaging, respectively. More accurate distribution of LRMs in embolized kidney and vessels could be detected by high-revolution visualization of micro-CT ex vivo. In conclusion, the LRMs were proved to be biocompatible and provide long-term radiopacity with good physical and mechanical properties for embolization.
    Type of Medium: Online Resource
    ISSN: 0885-3282 , 1530-8022
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2015
    detail.hit.zdb_id: 2072559-0
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...