    In: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, SAGE Publications, Vol. 42, No. 1 ( 2005-01-01), p. 41-46
    Abstract: Background: The Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) previously recommended use of the primary calibrator (JDS Lot 1) prepared by the former Committee for Standardization of Glycohemoglobin for standardizing the measurement of haemoglobin A1c (HbA1c). Owing to the depletion of vials of Lot 1 in March 2001, the present committee certified a new reference material, Lot 2, now distributed by the Health Care Technology Foundation (HECTEF). The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, which has values assigned from within Lot 1; the Lot 1 values were consensus values based on assays by laboratories in the Japanese national quality control programme. In this study, for the purpose of international comparison and standardization, Lot 2 was assayed by the JDS reference laboratories, the National Glycoprotein Standardization Program (NGSP) in the USA, and by reference laboratories approved by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Method: The HbA1c values of JDS Lot 2 were transferred from those assigned to Lot 1 using KO500, a high-resolution HPLC method, at three laboratories approved by the JDS committee. Subsequently, vials of JDS Lot 2 were shipped to and assayed by the NGSP in the USA and 10 IFCC reference laboratories. Result: The JDS-assigned HbA1c values (from Lot 1) are 4.04 for Level 1, 5.38 for Level 2, 7.32 for Level 3, 9.88 for Level 4, and 12.63 for Level 5, all expressed as a percentage of total haemoglobin. The values obtained by NGSP and the IFCC laboratories gave the following formulas: NGSP value (%) = JDS value (%) + 0.3%; IFCC value (%) = 1.068 x JDS value (%) -1.741%. Conclusion: Although the values obtained by the IFCC laboratories are significantly lower than the values assigned to Lot 2 by the JDS, the relationship is linear. In addition, standardization of HbA1c based on JDS Lot 2 is currently at a satisfactory level in Japan. As a result, the reassignment of values for Lot 2 to agree with the IFCC values should be relatively easy and will be done after all relevant parties agree to the change.
    Type of Medium: Online Resource
    ISSN: 0004-5632 , 1758-1001
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2005
    detail.hit.zdb_id: 2041298-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, SAGE Publications, Vol. 42, No. 1 ( 2005-01-01), p. 47-50
    Abstract: Background: In 2001, the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) prepared and certified a new reference material for haemoglobin A1c (HbA1c), Lot 2. The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, although some laboratories still use the previous material (Lot 1). The values assigned to Lot 2 were based on the consensus values for Lot 1 and should give the same results. Therefore, there should be no difference in the measured values no matter which calibrators are used. The Committee conducted a domestic survey in order to confirm this relationship. Method: In November 2002, four samples for HbA1c assay were sent to 795 laboratories as part of a national survey in Japan. Assays were performed using the laboratories' routine clinical methods. The coefficients of variation (CVs) of the reported values from all laboratories for the samples were calculated in order to determine the current level of standardization in Japan. Results: The overall CVs in the measured values for the four samples ranged from 2.7% to 4.0%. Values from laboratories using calibrators based on Lots 1 and 2 were similar. Conclusion: The present state of standardization for the routine measurement of HbA1c in Japan, as indicated by the 2002 survey, is excellent. This should aid in the eventual conversion of Lot 2 to IFCC-based values from the results of the 2002 national HbA1c survey.
    Type of Medium: Online Resource
    ISSN: 0004-5632 , 1758-1001
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2005