GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • MDPI AG  (3)
  • Ou, Mingxiong  (3)
Material
Publisher
  • MDPI AG  (3)
Language
Years
  • 1
    In: Agriculture, MDPI AG, Vol. 12, No. 6 ( 2022-06-20), p. 889-
    Abstract: An air-assisted electrostatic nozzle uses a combination of air-assisted atomization and electrostatic spray technology. This article optimizes the existing air-assisted electrostatic nozzles in terms of structural design to obtain a higher charge-to-mass ratio and a smaller droplet size. The optimized air-assisted electrostatic nozzle was studied experimentally, and the effects of liquid pressure, air pressure and applied voltage on the droplet size and charge-to-mass ratio were investigated. Comparing the effects of air pressure, liquid pressure and applied voltage on the charge-to-mass ratio and droplet size, the relationship curves of the droplet size and charge-to-mass ratio under each voltage were fitted using the Rayleigh charge limit theory. For a higher CMR during the spray operation, applied voltages between 2.5 kV and 3 kV, an air pressure between 0.4 bar and 0.6 bar, and a liquid pressure of less than 0.9 bar could be chosen. The optimized air-assisted electrostatic nozzles not only have small droplets but also have high charge-to-mass ratios, reducing the need for pesticide use and thus protecting human health and the environment.
    Type of Medium: Online Resource
    ISSN: 2077-0472
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2651678-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Applied Sciences, MDPI AG, Vol. 12, No. 16 ( 2022-08-11), p. 8058-
    Abstract: High clearance sprayer is a high-efficiency pesticide application machine in orchard management. In this paper, operational safety of high clearance sprayers is validated by using finite element simulation and vibration testing. The 3D model of the frame is simplified by using shell units instead of solid units, the static performance of high clearance sprayer frames under static full load and ultimate torsional conditions was studied by means of finite element simulation tests, the mechanical properties of the frame under step excitation were studied by multi-body dynamic simulation test. The simulation results show that, at a safety factor of 1.5, the maximum stress extremes in the frame are within the safe permissible stress range. During the dynamics analysis, a tire-ground contact simplified model was proposed. The results of the modal analysis show that the inherent frequency distribution of the high clearance sprayer is compact, and the vibration test has measured a large difference between the engine vibration frequency with the inherent frequency of the frame, this means that resonance will not occur. The theoretical analysis shows that the designed high clearance sprayer meets the requirements of large cross-row field operations, the study provides a reference for the overall design of the high clearance sprayer.
    Type of Medium: Online Resource
    ISSN: 2076-3417
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2704225-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Agriculture, MDPI AG, Vol. 12, No. 8 ( 2022-08-10), p. 1195-
    Abstract: To realize the online evaluation of spray quality, an online measuring system for spray coverage and deposition quality is developed. The measuring theory of spray coverage and deposition quality on an LWS (leaf wetness sensor) surface is analyzed. When the spray conditions are constant, there is a linear correlation between the spray coverage on the sensor surface, the spray deposition quality and the LWS output voltage increment. The results of calibration experiments show that when the spray conditions are constant, the coefficient of determination R2 of the regression curves between the sensor output voltage increment and the spray coverage on the sensor surface is more than 0.75, and the coefficient of determination R2 of the regression curves between the sensor output voltage increment and the spray deposition quality on the sensor surface is more than 0.90. Based on ZigBee wireless sensor technology, this paper reports an online measuring system for spray coverage and deposition quality at multiple points in the field. The test results show that the online measuring system has good uniformity. Field test results show that the LWS voltage increment and the coverage rate of water-sensitive paper have a good correlation, and the measuring results of the spray deposition quality trend are in good agreement. The fit of the spray deposition quality curves measured by the two methods was 0.8924. The research results in this paper can provide a reference for using LWS sensors to measure spray coverage and deposition quality.
    Type of Medium: Online Resource
    ISSN: 2077-0472
    Language: English
    Publisher: MDPI AG
    Publication Date: 2022
    detail.hit.zdb_id: 2651678-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...