In:
Critical Care Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 48, No. 3 ( 2020-03), p. e241-e248
Abstract:
Lung-protective ventilation for acute respiratory distress syndrome aims for providing sufficient oxygenation and carbon dioxide clearance, while limiting the harmful effects of mechanical ventilation. “Flow-controlled ventilation”, providing a constant expiratory flow, has been suggested as a new lung-protective ventilation strategy. The aim of this study was to test whether flow-controlled ventilation attenuates lung injury in an animal model of acute respiratory distress syndrome. Design: Preclinical, randomized controlled animal study. Setting: Animal research facility. Subjects: Nineteen German landrace hybrid pigs. Intervention: Flow-controlled ventilation (intervention group) or volume-controlled ventilation (control group) with identical tidal volume (7 mL/kg) and positive end-expiratory pressure (9 cm H 2 O) after inducing acute respiratory distress syndrome with oleic acid. Measurements and Main Results: Pa o 2 and Pa co 2 , minute volume, tracheal pressure, lung aeration measured via CT, alveolar wall thickness, cell infiltration, and surfactant protein A concentration in bronchoalveolar lavage fluid. Five pigs were excluded leaving n equals to 7 for each group. Compared with control, flow-controlled ventilation elevated Pa o 2 (154 ± 21 vs 105 ± 9 torr; 20.5 ± 2.8 vs 14.0 ± 1.2 kPa; p = 0.035) and achieved comparable Pa co 2 (57 ± 3 vs 54 ± 1 torr; 7.6 ± 0.4 vs 7.1 ± 0.1 kPa; p = 0.37) with a lower minute volume (6.4 ± 0.5 vs 8.7 ± 0.4 L/min; p 〈 0.001). Inspiratory plateau pressure was comparable in both groups (31 ± 2 vs 34 ± 2 cm H 2 O; p = 0.16). Flow-controlled ventilation increased normally aerated (24% ± 4% vs 10% ± 2%; p = 0.004) and decreased nonaerated lung volume (23% ± 6% vs 38% ± 5%; p = 0.033) in the dependent lung region. Alveolar walls were thinner (5.5 ± 0.1 vs 7.8 ± 0.2 µm; p 〈 0.0001), cell infiltration was lower (20 ± 2 vs 32 ± 2 n /field; p 〈 0.0001), and normalized surfactant protein A concentration was higher with flow-controlled ventilation (1.1 ± 0.04 vs 1.0 ± 0.03; p = 0.039). Conclusions: Flow-controlled ventilation enhances lung aeration in the dependent lung region and consequently improves gas exchange and attenuates lung injury. Control of the expiratory flow may provide a novel option for lung-protective ventilation.
Type of Medium:
Online Resource
ISSN:
0090-3493
DOI:
10.1097/CCM.0000000000004209
Language:
English
Publisher:
Ovid Technologies (Wolters Kluwer Health)
Publication Date:
2020
detail.hit.zdb_id:
2034247-0
Permalink