GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Journal of Neurosurgery Publishing Group (JNSPG)  (1)
  • Mansvelt Beck, Hendricus J.  (1)
Material
Publisher
  • Journal of Neurosurgery Publishing Group (JNSPG)  (1)
Person/Organisation
Language
Years
Subjects(RVK)
  • 1
    In: Journal of Neurosurgery, Journal of Neurosurgery Publishing Group (JNSPG), Vol. 107, No. 6 ( 2007-12), p. 1190-1197
    Abstract: Cerebral aneurysms that cannot be treated by clip or coil placement can be treated with high-flow bypass surgery using techniques such as the excimer laser–assisted nonocclusive anastomosis (ELANA). To simplify the technique, a sutureless ELANA (SELANA) was developed in combination with an expanded polytetrafluoroethylene (ePTFE) graft. Methods In 18 rabbits a bypass was constructed on the abdominal aorta using the SELANA technique with an ePTFE graft, resulting in 18 bypasses and 36 anastomoses. Short-term effects were analyzed in the first 2 weeks and at 2 and 3 months after the procedure. Patency was evaluated using quantitative ultrasound flowmetry. The anastomotic sites were studied using scanning electron microscopy. Results Construction of the bypass using the SELANA technique was easier and faster (15–25 minutes) compared with bypasses made with the ELANA technique ( 〉 90 minutes). At the end of follow-up, 16 of 18 bypasses were patent. Of 36 SELANA anastomoses, 32 could be completed without short temporary occlusion of the recipient vessel. Scanning electron microscopy showed complete coverage of all anastomoses with neointimal repair tissue after 10 days. Conclusions The SELANA technique provides further advantages over the conventional ELANA technique in ease of use and shortening of procedure time. The patency rate in this series was 89% and neointima repair tissue at the anastomosis site was complete after 10 days. Further experimental studies of the long-term patency and safety of this technique are necessary before clinical application.
    Type of Medium: Online Resource
    ISSN: 0022-3085 , 1933-0693
    RVK:
    RVK:
    Language: Unknown
    Publisher: Journal of Neurosurgery Publishing Group (JNSPG)
    Publication Date: 2007
    detail.hit.zdb_id: 2026156-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...