GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Liu, Xijun  (2)
  • Yang, Guolong  (2)
Material
Publisher
Person/Organisation
Language
Years
  • 1
    Online Resource
    Online Resource
    IOP Publishing ; 2019
    In:  IOP Conference Series: Materials Science and Engineering Vol. 677, No. 5 ( 2019-12-01), p. 052006-
    In: IOP Conference Series: Materials Science and Engineering, IOP Publishing, Vol. 677, No. 5 ( 2019-12-01), p. 052006-
    Abstract: According to the actual acceleration index requirements, a high-speed large-thrust linear induction motor for accelerating the system was designed. Due to the variable pole pitch design, the variation of the pole pitch plays a key role in the design, and the influence of the variation of the pole pitch on the output of the electromagnetic thrust is analyzed. The variable pole distance double-sided linear induction motor is used as the acceleration drive. It does not need to detect the speed and displacement. The primary winding current frequency is constant. As the speed increases, it will not be limited by the inverter frequency, and will not increase the motor loss. The frequency is constant and the control is optimized and simpler.
    Type of Medium: Online Resource
    ISSN: 1757-8981 , 1757-899X
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2019
    detail.hit.zdb_id: 2506501-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Journal of Physics D: Applied Physics, IOP Publishing, Vol. 56, No. 29 ( 2023-07-20), p. 294004-
    Abstract: This paper reports on experimental studies of point discharge in oil-paper insulation under different hydraulic pressures. The point partial discharge of oil-paper insulation under different hydraulic pressure was measured for the first time. With the help of a commercial partial discharge detector, five discharge parameters under constant AC voltage were recorded and plotted as curves. These show that the partial discharge under very low pressure developed very quickly after it was initiated. So, care should be taken with oil-paper equipment operating at high altitudes, because once the discharge is initiated, it would develop into a catastrophe in a relatively short time. The partial discharge inception voltage and breakdown voltage increased with pressure, but the rising rates decreased with the increase of pressure. The discharge parameters decreased with pressure but the difference between the adjacent curves became smaller and smaller, which is called the saturation characteristic of the hydraulic pressure’s effect on discharge. Therefore, very high hydraulic pressure is not necessary for weakening the partial discharge in oil paper insulation. It is believed that the hydraulic pressure influences the discharge in the oil-paper insulation by changing the state of the gas in this compound insulation system. This paper provides a reference for the operation and maintenance of oil-paper insulation equipment running in high-altitude areas. Adjusting hydraulic pressure might be an effective and economical way to reduce the size and weight of oil-paper insulation equipment.
    Type of Medium: Online Resource
    ISSN: 0022-3727 , 1361-6463
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2023
    detail.hit.zdb_id: 209221-9
    detail.hit.zdb_id: 1472948-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...