GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Association for Cancer Research (AACR)  (3)
  • Kuwata, Taiji  (3)
Material
Publisher
  • American Association for Cancer Research (AACR)  (3)
Language
Years
Subjects(RVK)
  • 1
    In: Cancer Research, American Association for Cancer Research (AACR), Vol. 77, No. 13_Supplement ( 2017-07-01), p. 1721-1721
    Abstract: Background: Circulating tumor cells (CTCs) are tumor cells shed from primary tumor and circulate in the peripheral blood. CTCs, as a surrogate of distant metastasis, can be potentially useful in diagnosis and monitoring therapeutic effects in malignant tumors. Among a variety of systems for detection of CTCs, the “Cellsearch” is the only approved system for clinical use. However, EpCAM-negative tumor cells, such as those originating from non-epithelial cells and those undergoing epithelial-mesenchymal transition (EMT) cannot be captured with the “CellSearch” that is an EpCAM-based isolation system. Therefore, we have developed a novel polymeric microfluidic device (“Universal” CTC-chip) that can capture CTCs with or without EpCAM expression (AACR 2015). In the present study, we examined CTCs-detection performance of the CTC-chip in patients with thoracic malignant tumors (lung cancer [LC] as an “EpCAM-positive” tumor and malignant pleural mesothelioma [MPM] as an “EpCAM-negative” tumor) in comparison with that of the CellSearch. Methods: Peripheral blood sampled from each patient was divided and subjected to quantitative evaluation of CTCs with the CTC-chip as well as with the “CellSearch”. The CTC-chip, coated with an anti-EpCAM antibody, was used to capture CTCs in the blood samples (n=19) from lung cancer patients. To capture CTCs in the samples (n=11) from MPM patients, the CTC-chip was coated with an antibody against podoplanin that is expressed on the mesothelioma. After immuno-staining for cytokeratin and CD45 on the chip, a captured cell containing Hoechst-positive nucleus and cytokeratin-positive/ CD45-negative cytoplasm was judged as a CTC. The CTC-count for each sample was represented as the number per 7.5mL of the blood. Results: The median CTC-count detected with the CTC-chip in LC was 50 (range, 0-270), which was significantly higher than that (the median CTC-count, 0; range, 0-47) with the CellSearch (p & lt;0.01). In the peripheral blood sampled from MPM patients, CTC was detected in only one patient using the CellSearch, but was detected in all 11 patients with the median CTC-count of 144 (range 0-470). Conclusion: The “universal” CTC-chip achieved higher performance in detection of CTCs of thoracic malignant tumors as compared with the CellSearch. The updated data will be presented at the AACR annual meeting 2017. Citation Format: Kazue Yoneda, Taiji Kuwata, Yasuhiro Chikaishi, Kenichi Kobayashi, Sakiko Yura, Hiroki Matsumiya, Masatoshi Kanayama, Akihiro Taira, Yusuke Nabe, Shinji Shinohara, Masaru Takenaka, Soichi Oka, Ayako Hirai, Yuko Tashima, Naoko Imanishi, Koji Kuroda, Fumihiro Tanaka. Detection of CTCs in thoracic malignant tumors with "universal" CTC-chip [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 1721. doi:10.1158/1538-7445.AM2017-1721
    Type of Medium: Online Resource
    ISSN: 0008-5472 , 1538-7445
    RVK:
    RVK:
    Language: English
    Publisher: American Association for Cancer Research (AACR)
    Publication Date: 2017
    detail.hit.zdb_id: 2036785-5
    detail.hit.zdb_id: 1432-1
    detail.hit.zdb_id: 410466-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Cancer Research, American Association for Cancer Research (AACR), Vol. 79, No. 13_Supplement ( 2019-07-01), p. 3149-3149
    Abstract: Aim: To investigate the prognostic impact of programmed death-ligand 1 (PD-L1) expression on tumor cells in correlation with neutrophil-to-lymphocyte ratio (NLR) in early-stage squamous cell carcinoma of the lung, as PD-L1 is a potent regulator of cancer immunity and NLR is a potential surrogate of immune status. Patients and methods: Eighty-three patients with completely resected pathologic stage I lung squamous cell carcinoma were retrospectively reviewed. Tumoral PD-L1 expression was evaluated with immunohistochemistry, and its prognostic impact was analyzed in correlation with NLR. Results: Forty-three patients (51.8%) had tumor with positive PD-L1 expression (percentage of tumor cells expressing PD-L1, ≥1%). There was no significant correlation between PD-L1 expression and NLR. PD-L1-positivity failed to provide a significant prognostic impact (overall survival [OS] rate at 5 years, 70.1% in PD-L1-negative patients versus 53.0% in PD-L1-positive patients; P=0.117). Among NLR-low ( & lt;2.2) patients, however, PD-L1-positivity was significantly correlated with a poor prognosis (OS rate at 5 years, 86.0% in PD-L1-negative patients versus 46.1% in PD-L1-positive patients; P=0.020). In contrast, among NLR-high (≥2.2) patients, PD-L1-positivity provided no prognostic impact (P=0.680). When NLR status and tumoral PD-L1 status were combined, “NLR-low and tumoral PD-L1-negative” was a significant and independent factor to predict a favorable recurrence-free survival (hazard ratio, 0.237 [95% confidence interval, 0.083 to 0.674]; P=0.007) and OS (hazard ratio, 0.260 [95% confidence interval, 0.091 to 0.745] ; P=0.012). Conclusions: The prognostic impact of PD-L1 expression on tumor cells was distinct according to NLR. “NLR-low and tumoral PD-L1-negative” patients showed a favorable prognosis. Citation Format: Kazue Yoneda, Taiji Kuwata, Masataka Mori, Masatoshi Kanayama, Ayako Hirai, Yuko Tashima, Naoko Imanishi, Koji Kuroda, Yoshinobu Ichiki, Fumihiro Tanaka. Prognostic impact of PD-L1 expression in correlation with neutrophil-to-lymphocyte ratio in squamous cell carcinoma of the lung [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2019; 2019 Mar 29-Apr 3; Atlanta, GA. Philadelphia (PA): AACR; Cancer Res 2019;79(13 Suppl):Abstract nr 3149.
    Type of Medium: Online Resource
    ISSN: 0008-5472 , 1538-7445
    RVK:
    RVK:
    Language: English
    Publisher: American Association for Cancer Research (AACR)
    Publication Date: 2019
    detail.hit.zdb_id: 2036785-5
    detail.hit.zdb_id: 1432-1
    detail.hit.zdb_id: 410466-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    American Association for Cancer Research (AACR) ; 2018
    In:  Cancer Research Vol. 78, No. 13_Supplement ( 2018-07-01), p. 1599-1599
    In: Cancer Research, American Association for Cancer Research (AACR), Vol. 78, No. 13_Supplement ( 2018-07-01), p. 1599-1599
    Abstract: Background: Circulating tumor cells (CTCs) are not only a surrogate of distant metastasis, but also useful for material of liquid biopsy. "Universal" CTC-chip is a polymeric microfluidic device that can capture CTCs according to their surface marker from whole blood. We have examined the capture efficiency of lung cancer and mesothelioma cells in the blood with CTC-chip coated with antibodies against various surface marker. Methods: Lung cancer cell lines (PC-9) or mesothelioma cell lines (ACC-MESO-4, MSTO-211H) were used in this study. Cells were CFSE-labeled and added in the blood of healthy donor. A polymeric CTC-chip was coated with two steps: base- and capture-antibody. As capture antibody, we used anti-EpCAM, podoplanin, and EGFR antibody. After flowing these samples, capture efficiency was calculated (number of captured cells/number of flowed cells). Results: Capture efficiency of PC-9, MESO-4, and METO-211H was 100.0%, 9.5% and 9.1% (EpCAM-chip; anti-EpCAM antibody clone HEA125); 5.8%, 85.9% and 9.0 % (podoplanin-chip; anti-podoplanin antibody clone E1); 38.6, 112.5%, 11.7% (podoplanin-chip; anti-podoplanin antibody clone NZ-1); 30.2%, 21.8%, 38.5% (EGFR-chip; anti-EGFR antibody clone 528), respectively. Conclusion: Using "Universal CTC-chip" with various antibodies, it was possible to capture nonepithelial tumor cells such as mesothelioma cells. Citation Format: Kazue Yoneda, Taiji Kuwata, Fumihiro Tanaka. Capture of tumor cells in blood with "Universal CTC-chip" [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2018; 2018 Apr 14-18; Chicago, IL. Philadelphia (PA): AACR; Cancer Res 2018;78(13 Suppl):Abstract nr 1599.
    Type of Medium: Online Resource
    ISSN: 0008-5472 , 1538-7445
    RVK:
    RVK:
    Language: English
    Publisher: American Association for Cancer Research (AACR)
    Publication Date: 2018
    detail.hit.zdb_id: 2036785-5
    detail.hit.zdb_id: 1432-1
    detail.hit.zdb_id: 410466-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...