GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Georg Thieme Verlag KG  (4)
  • Keuchel, Martin  (4)
  • 1
    In: Endoscopy International Open, Georg Thieme Verlag KG, Vol. 09, No. 06 ( 2021-06), p. E802-E823
    Abstract: Capsule endoscopy (CE) emerged out of the pressing clinical need to image the small bowel (SB) in cases of midgut bleeding and provide an overall comfortable and reliable gastrointestinal (GI) diagnosis 1. Since its wider adoption in clinical practice, significant progress has been made in several areas including software development, hardware features and clinical indications, while innovative applications of CE never cease to appear 2 3. Currently, several manufacturers provide endoscopic capsules with more or less similar technological features 4. Although there is engaging and continuous academic and industry-fueled R & D, promising furtherment of CE technology 4 5, the current status of clinical CE remains that of by and large an imaging modality. Clinical relevance of CE images is cornerstone in the decision-making process for medical management. In one of the larger to date SB CE studies, 4,206 abnormal images were detected in 3,280 patients 6. Thus, CE leads to the identification of a large amount of potential pathology, some of which are pertinent (or relevant) while some (probably the majority) are not. Soon artificial intelligence (AI) is likely to carry out several roles currently performed by humans; in fact, we are witnessing only the first stages of a transition in the clinical adoption of AI-based solutions in several aspects of gastroenterology including CE 7. Until then though, human-based decision-making profoundly impacts patient care and – although not suggested in the updated European Society of Gastrointestinal Endoscopy (ESGE) European curriculum 8 9 – it should be an integral part of CE training. Frequently, interpretation of CE images by experts or at least experienced readers differs. In a tandem CE reading study, expert review of discordant cases revealed a 50 % (13/25 discordant results) error rate by experienced readers, corresponding (in 5/13 cases) to ‘over-classification’ of an irrelevant abnormality 10. Another comparative study showed an ‘over-classification’ of such irrelevant abnormalities in ~10 % of CE readings 11. One thing which has been for a while on the table – in relation to optimizing and/or standardizing CE reporting and subsequent decision-making – is the need for reproducible scoring systems and for a reliable common language among clinicians responsible for further patient’s management. Over the years, several of these scoring systems were developed while others appear in the wake of software and hardware improvements aiming to replace and/or complement their predecessors. This review presents a comprehensive account of the currently available classification/scoring systems in clinical CE spanning from predicting the bleeding potential of identified SB lesions (with emphasis on vascular lesions), and the individual rebleeding risk; scoring systems for the prediction of SB lesions in patients with obscure gastrointestinal bleeding (OGlB), having the potential to improve patient selection and rationalize the use of enteroscopy, with better allocation of resources, optimized diagnostic workflow and tailored treatment. This review also includes scores for reporting the inflammatory burden, the cleansing level that underscores confidence in CE reporting and the mass or bulge question in CE. Essentially, the aim is to become a main text for reference when scoring is required and facilitate the inclusion of -through readiness of access- one of the other in the final report.
    Type of Medium: Online Resource
    ISSN: 2364-3722 , 2196-9736
    Language: English
    Publisher: Georg Thieme Verlag KG
    Publication Date: 2021
    detail.hit.zdb_id: 2761052-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Endoscopy, Georg Thieme Verlag KG, Vol. 53, No. 09 ( 2021-09), p. 970-980
    Abstract: Background We aimed to document international practices in small-bowel capsule endoscopy (SBCE), measuring adherence to European Society of Gastrointestinal Endoscopy (ESGE) technical and clinical recommendations. Methods Participants reached through the ESGE contact list completed a 52-item web-based survey. Results 217 responded from 47 countries (176 and 41, respectively, from countries with or without a national society affiliated to ESGE). Of respondents, 45 % had undergone formal SBCE training. Among SBCE procedures, 91 % were performed with an ESGE recommended indication, obscure gastrointestinal bleeding (OGIB), iron-deficiency anemia (IDA), and suspected/established Crohn’s disease being the commonest and with higher rates of positive findings (49.4 %, 38.2 % and 53.5 %, respectively). A watchful waiting strategy after a negative SBCE for OGIB or IDA was preferred by 46.7 % and 70.3 %, respectively. SBCE was a second-line exam for evaluation of extent of new Crohn’s disease for 62.2 % of respondents. Endoscopists adhered to varying extents to ESGE technical recommendations regarding bowel preparation (  〉  60 %), use in those with pacemaker holders (62.5 %), patency capsule use (51.2 %), and use of a validated scale for bowel preparation assessment (13.3 %). Of the respondents, 67 % read and interpreted the exams themselves and 84 % classified exams findings as relevant or irrelevant. Two thirds anticipated future increase in SBCE demand. Inability to obtain tissue (78.3 %) and high cost (68.1 %) were regarded as the main limitations, and implementation of artificial intelligence as the top development priority (56.2 %). Conclusions To some extent, endoscopists follow ESGE guidelines on using SBCE in clinical practice. However, variations in practice have been identified, whose implications require further evaluation.
    Type of Medium: Online Resource
    ISSN: 0013-726X , 1438-8812
    RVK:
    RVK:
    Language: English
    Publisher: Georg Thieme Verlag KG
    Publication Date: 2021
    detail.hit.zdb_id: 2026213-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Endoscopy International Open, Georg Thieme Verlag KG, Vol. 09, No. 06 ( 2021-06), p. C6-C6
    Type of Medium: Online Resource
    ISSN: 2364-3722 , 2196-9736
    Language: English
    Publisher: Georg Thieme Verlag KG
    Publication Date: 2021
    detail.hit.zdb_id: 2761052-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Endoscopy, Georg Thieme Verlag KG, Vol. 55, No. 01 ( 2023-01), p. 58-95
    Abstract: MR1 ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2 ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3 ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4 ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5 ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6 ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7 ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn’s disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8 ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9 ESGE recommends, in patients with established Crohn’s disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10 ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11 ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.
    Type of Medium: Online Resource
    ISSN: 0013-726X , 1438-8812
    RVK:
    RVK:
    Language: English
    Publisher: Georg Thieme Verlag KG
    Publication Date: 2023
    detail.hit.zdb_id: 2026213-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...