GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • American Society for Microbiology  (2)
  • Kafufu, Bosco  (2)
Material
Publisher
  • American Society for Microbiology  (2)
Language
Years
Subjects(RVK)
  • 1
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 58, No. 4 ( 2020-03-25)
    Abstract: Early cryptococcal disease can be detected via circulating antigen in blood before fulminant meningitis develops, when early antifungal therapy improves survival. Two semiquantitative cryptococcal antigen (CrAg) lateral flow assays (LFAs) have been developed, but their diagnostic performance has not been defined. Cryopreserved serum samples from HIV-infected Ugandans obtained as part of a prospective CrAg-screening cohort were tested in duplicate for CrAg by the CrAgSQ (IMMY) and CryptoPS (Biosynex) lateral flow assays. Case-controlled diagnostic performance was measured using the FDA-approved CrAg LFA (IMMY) as a reference standard via McNemar’s test. Of 99 serum samples tested, 57 were CrAg positive (CrAg + ) by the CrAg LFA reference standard. By CrAgSQ, 57 were read as positive, with 98% sensitivity (56/57; 95% confidence interval [CI], 0.91 to 0.99) and 98% specificity (41/42; 95% CI, 0.88 to 0.99) (McNemar’s, P  = 0.99). The sample with a false-negative result by CrAgSQ ( n  = 1) had a titer of 〈 1:5, while the sample with a false-positive result ( n  = 1) yielded a 1+ result. By CryptoPS, 52 samples were read as positive, with 88% sensitivity (50/57; 95% CI, 0.76 to 0.95) and 95% specificity (40/42; 95% CI, 0.84 to 0.99) (McNemar’s, P  = 0.18). The CryptoPS false-negative results included samples with titers of 〈 1:5 ( n  = 1), 1:5 ( n  = 5), and 1:20 ( n  = 1), while samples with false-positive results by CryptoPS ( n  = 2) yielded Positive results. The CryptoPS assay missed 35% (7/20) of samples with CrAg LFA titers of ≤1:20. The new semiquantitative CrAg LFAs allow rapid estimation of titer levels in easy-to-perform platforms. The CrAgSQ demonstrated better qualitative sensitivity and specificity than the CryptoPS compared to the reference standard. The exact grading of the CrAgSQ results has some subjectivity, with interreader variability; however, qualitative reads were generally concordant for both assays.
    Type of Medium: Online Resource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Language: English
    Publisher: American Society for Microbiology
    Publication Date: 2020
    detail.hit.zdb_id: 1498353-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 59, No. 8 ( 2021-07-19)
    Abstract: A newly developed cryptococcal antigen (CrAg) semiquantitative (SQ) lateral flow assay (LFA) provides a semiquantitative result in a rapid one-step test instead of performing serial dilutions to determine CrAg titer. We prospectively compared the diagnostic performance of the CrAgSQ assay (IMMY) with the CrAg LFA (IMMY) on cerebrospinal fluid (CSF) samples collected from persons with HIV-associated meningitis. The CrAgSQ grades (1+ to 5+) were compared with CrAg LFA titers and quantitative CSF fungal cultures. Among 87 participants screened for HIV-associated meningitis, 60 had cryptococcal meningitis (59 CrAg positive [CrAg + ] by LFA and 1 false negative due to prozone with CrAg LFA titer of 1:1,310,000 and culture positivity), and 27 had no cryptococcal meningitis by CrAg LFA or culture. The CrAgSQ on CSF had 100% (60/60) sensitivity and 100% specificity (27/27). CSF CrAg titers ranged from 1:5 to 1:42 million. CrAgSQ grades of 1+, 2+, 3+, 4+, and 5+ corresponded to median CrAg LFA titers of 1: 〈 10, 1:60, 1:7,680, 1:81,920, and 1:1,474,000, respectively. CSF CrAgSQ grades 3+ or higher were always CSF culture positive. Mortality at 14 days for those with low CrAgSQ grade (1+ to 3+) was 5% (1/22) versus 21% (8/38) with high CrAgSQ grades (4+ to 5+) ( P  = 0.084). The CrAgSQ demonstrates excellent diagnostic performance, maintaining both the sensitivity and specificity of the CrAg LFA, and counters false-negative prozone effects. The CrAgSQ assay reading is more complex but does provide useful clinical information about disease burden and probability of culture positivity in a single rapid diagnostic test.
    Type of Medium: Online Resource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Language: English
    Publisher: American Society for Microbiology
    Publication Date: 2021
    detail.hit.zdb_id: 1498353-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...