GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • SAGE Publications  (4)
  • Johnson, Mary L.  (4)
  • 1
    In: Journal of Diabetes Science and Technology, SAGE Publications, Vol. 16, No. 5 ( 2022-09), p. 1167-1173
    Abstract: CeQur Simplicity™ (CeQur, Marlborough, MA) is a 3-day insulin delivery patch designed to meet mealtime insulin requirements. A recently reported 48-week, randomized, multicenter, interventional trial compared efficacy, safety and self-reported outcomes in 278 adults with type 2 diabetes (T2D) on basal insulin therapy who initiated and managed mealtime insulin therapy with a patch pump versus insulin pen. We assessed changes in key glycemic metrics among a subset of patients who wore a continuous glucose monitoring (CGM) device. Methods: Study participants (patch, n = 49; pen, n = 48) wore a CGM device in masked setting during the baseline period and prior to week 24. Glycemic control was assessed using international consensus guidelines for percentage of Time In Range (%TIR: 〉 70% at 70-180 mg/dL), Time Below Range (%TBR: 〈 4% at 〈 70 mg/dL; 〈 1% at 〈 54 mg/dL), and Time Above Range (%TAR: 〈 25% at 〉 180 mg/dL; 〈 5% at 〉 250 mg/dL). Results: Both the patch and pen groups achieved recommended targets in %TIR (74.1% ± 18.7%, 75.2 ± 16.1%, respectively) and marked reductions in %TAR 〉 180 mg/dL (21.1% ± 19.9%, 19.7% ± 17.5%, respectively) but with increased %TBR 〈 70 mg/dL (4.7% ± 5.2%, 5.1 ± 5.8, respectively), all P 〈 .0001. No significant between-group differences in glycemic improvements or adverse events were observed. Conclusions: CGM confirmed that the patch or pen can be used to safely initiate and optimize basal-bolus therapy using a simple insulin adjustment algorithm with SMBG. Preference data suggest that use of the patch vs pen may enhance treatment adherence.
    Type of Medium: Online Resource
    ISSN: 1932-2968 , 1932-2968
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2022
    detail.hit.zdb_id: 2467312-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    SAGE Publications ; 2020
    In:  Journal of Diabetes Science and Technology Vol. 14, No. 4 ( 2020-07), p. 725-726
    In: Journal of Diabetes Science and Technology, SAGE Publications, Vol. 14, No. 4 ( 2020-07), p. 725-726
    Type of Medium: Online Resource
    ISSN: 1932-2968 , 1932-2968
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2020
    detail.hit.zdb_id: 2467312-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    SAGE Publications ; 2019
    In:  Journal of Diabetes Science and Technology Vol. 13, No. 4 ( 2019-07), p. 614-626
    In: Journal of Diabetes Science and Technology, SAGE Publications, Vol. 13, No. 4 ( 2019-07), p. 614-626
    Abstract: As the use of continuous glucose monitoring (CGM) increases, there is a need to better understand key metrics of time in range 70-180 mg/dL (TIR 70-180 ) and hyperglycemia and how they relate to hemoglobin A1c (A1C). Methods: Analyses were conducted utilizing datasets from four randomized trials encompassing 545 adults with type 1 diabetes (T1D) who had central-laboratory measurements of A1C. CGM metrics were calculated and compared with each other and A1C cross-sectionally and longitudinally. Results: Correlations among CGM metrics (TIR 70-180 , time 〉 180 mg/dL, time 〉 250 mg/dL, mean glucose, area under the curve above 180 mg/dL, high blood glucose index, and time in range 70-140 mg/dL) were typically 0.90 or greater. Correlations of each metric with A1C were lower (absolute values 0.66-0.71 at baseline and 0.73-0.78 at month 6). For a given TIR 70-180 percentage, there was a wide range of possible A1C levels that could be associated with that TIR 70-180 level. On average, a TIR 70-180 of 70% and 50% corresponded with an A1C of approximately 7% and 8%, respectively. There also was considerable spread of change in A1C for a given change in TIR 70-180 , and vice versa. An increase in TIR 70-180 of 10% (2.4 hours per day) corresponded to a decrease in A1C of 0.6%, on average. Conclusions: In T1D, CGM measures reflecting hyperglycemia (including TIR and mean glucose) are highly correlated with each other but only moderately correlated with A1C. For a given TIR or change in TIR there is a wide range of possible corresponding A1C values.
    Type of Medium: Online Resource
    ISSN: 1932-2968 , 1932-2968
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2019
    detail.hit.zdb_id: 2467312-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    SAGE Publications ; 2021
    In:  Journal of Diabetes Science and Technology Vol. 15, No. 3 ( 2021-05), p. 539-545
    In: Journal of Diabetes Science and Technology, SAGE Publications, Vol. 15, No. 3 ( 2021-05), p. 539-545
    Abstract: Little data exists regarding the impact of continuous glucose monitoring (CGM) in the primary care management of type 2 diabetes (T2D). We initiated a quality improvement (QI) project in a large healthcare system to determine the effect of professional CGM (pCGM) on glucose management. We evaluated both an MD and RN/Certified Diabetes Care and Education Specialist (CDCES) Care Model. Methods: Participants with T2D for 〉 1 yr., A1C ≥7.0% to 〈 11.0%, managed with any T2D regimen and willing to use pCGM were included. Baseline A1C was collected and participants wore a pCGM (Libre Pro) for up to 2 weeks, followed by a visit with an MD or RN/CDCES to review CGM data including Ambulatory Glucose Profile (AGP) Report. Shared-decision making was used to modify lifestyle and medications. Clinic follow-up in 3 to 6 months included an A1C and, in a subset, a repeat pCGM. Results: Sixty-eight participants average age 61.6 years, average duration of T2D 15 years, mean A1C 8.8%, were identified. Pre to post pCGM lowered A1C from 8.8% ± 1.2% to 8.2% ± 1.3% (n=68, P=0.006). The time in range (TIR) and time in hyperglycemia improved along with more hypoglycemia in the subset of 37 participants who wore a second pCGM. Glycemic improvement was due to lifestyle counseling (68% of participants) and intensification of therapy (65% of participants), rather than addition of medications. Conclusions: Using pCGM in primary care, with an MD or RN/CDCES Care Model, is effective at lowering A1C, increasing TIR and reducing time in hyperglycemia without necessarily requiring additional medications.
    Type of Medium: Online Resource
    ISSN: 1932-2968 , 1932-2968
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2021
    detail.hit.zdb_id: 2467312-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗