In:
Indoor and Built Environment, SAGE Publications, Vol. 26, No. 4 ( 2017-04), p. 576-584
Abstract:
Field monitoring is critical in the examination of indoor air quality (IAQ) which offers an integrated assessment of human exposure. A good measurement protocol includes appropriate methodologies and compliance of quality control and quality assurance procedures. In China, there has been a huge economic growth in the past 20 years and living standard for Chinese citizens has been improving with a rapid development in urban cities and infrastructures. With these developments, there have been a growth of increasing pollution sources, and IAQ has been a major concern to the government and many Chinese citizens with widespread reports of the coherent health impacts. However, the indoor monitoring in China is full of technical challenges. In this paper, we review the difficulties in conducting IAQ assessment in China. Techniques and practical consideration have been proposed accordingly.
Type of Medium:
Online Resource
ISSN:
1420-326X
,
1423-0070
DOI:
10.1177/1420326X15626991
Language:
English
Publisher:
SAGE Publications
Publication Date:
2017
detail.hit.zdb_id:
1482713-X
Permalink