GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Online Resource
    Online Resource
    Elsevier BV ; 2023
    In:  Burns Vol. 49, No. 5 ( 2023-08), p. 1052-1061
    In: Burns, Elsevier BV, Vol. 49, No. 5 ( 2023-08), p. 1052-1061
    Type of Medium: Online Resource
    ISSN: 0305-4179
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2023
    detail.hit.zdb_id: 2025040-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2021
    In:  JBJS Case Connector Vol. 11, No. 2 ( 2021-5-10)
    In: JBJS Case Connector, Ovid Technologies (Wolters Kluwer Health), Vol. 11, No. 2 ( 2021-5-10)
    Abstract: A 24-year-old man with right unilateral hip disarticulation, intolerant of a traditional socket-mounted prosthesis (TSP), underwent pelvic transcutaneous osseointegration and was fit with a prosthetic lower extremity 7 months later. Twenty-four months after osseointegration, he remains pain-free and complication-free, wears his prosthesis all waking hours, walks without assistive devices and can carry 2-handed objects, and works as a livestock farmer. Conclusion: Through 24 months, the world's first patient with pelvic osseointegration has no complications and better mobility than most patients with unilateral hip disarticulation using TSPs. Pelvic osseointegration seems reasonable to further consider in carefully selected patients.
    Type of Medium: Online Resource
    ISSN: 2160-3251
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    British Editorial Society of Bone & Joint Surgery ; 2020
    In:  The Bone & Joint Journal Vol. 102-B, No. 2 ( 2020-02), p. 162-169
    In: The Bone & Joint Journal, British Editorial Society of Bone & Joint Surgery, Vol. 102-B, No. 2 ( 2020-02), p. 162-169
    Abstract: Osseointegrated prosthetic limbs allow better mobility than socket-mounted prosthetics for lower limb amputees. Fractures, however, can occur in the residual limb, but they have rarely been reported. Approximately 2% to 3% of amputees with socket-mounted prostheses may fracture within five years. This is the first study which directly addresses the risks and management of periprosthetic osseointegration fractures in amputees. Methods A retrospective review identified 518 osseointegration procedures which were undertaken in 458 patients between 2010 and 2018 for whom complete medical records were available. Potential risk factors including time since amputation, age at osseointegration, bone density, weight, uni/bilateral implantation and sex were evaluated with multiple logistic regression. The mechanism of injury, technique and implant that was used for fixation of the fracture, pre-osseointegration and post fracture mobility (assessed using the K-level) and the time that the prosthesis was worn for in hours/day were also assessed. Results There were 22 periprosthetic fractures; they occurred exclusively in the femur: two in the femoral neck, 14 intertrochanteric and six subtrochanteric, representing 4.2% of 518 osseointegration operations and 6.3% of 347 femoral implants. The vast majority (19/22, 86.4%) occurred within 2 cm of the proximal tip of the implant and after a fall. No fractures occurred spontaneously. Fixation most commonly involved dynamic hip screws (10) and reconstruction plates (9). No osseointegration implants required removal, the K-level was not reduced after fixation of the fracture in any patient, and all retained a K-level of ≥ 2. All fractures united, 21 out of 22 patients (95.5%) wear their osseointegration-mounted prosthetic limb longer daily than when using a socket, with 18 out of 22 (81.8%) reporting using it for ≥ 16 hours daily. Regression analysis identified a 3.89-fold increased risk of fracture for females (p = 0.007) and a 1.02-fold increased risk of fracture per kg above a mean of 80.4 kg (p = 0.046). No increased risk was identified for bilateral implants (p = 0.083), time from amputation to osseointegration (p = 0.974), age at osseointegration (p = 0.331), or bone density (g/cm2, p = 0.560; T-score, p = 0.247; Z-score, p = 0.312). Conclusion The risks and sequelae of periprosthetic fracture after press-fit osseointegration for amputation should not deter patients or clinicians from considering this procedure. Females and heavier patients are likely to have an increased risk of fracture. Age, years since amputation, and bone density do not appear influential. Cite this article: Bone Joint J 2020;102-B(2):162–169.
    Type of Medium: Online Resource
    ISSN: 2049-4394 , 2049-4408
    Language: English
    Publisher: British Editorial Society of Bone & Joint Surgery
    Publication Date: 2020
    detail.hit.zdb_id: 2697480-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2020
    In:  Techniques in Orthopaedics Vol. 35, No. 3 ( 2020-06-30), p. 209-213
    In: Techniques in Orthopaedics, Ovid Technologies (Wolters Kluwer Health), Vol. 35, No. 3 ( 2020-06-30), p. 209-213
    Abstract: Distraction osteogenesis can be performed for transfemoral amputees using a motorized intramedullary limb lengthening nail (LLN) such as the 14×130 mm NuVasive Freedom nail. Despite being the shortest commercially available LLN, some patients have even shorter residual femurs, making it impossible to link the bone to the nail by the standard technique of inserting a cross-locking bolt through the proximal and distal nail holes. Two modified techniques of linking a very short femur to a LLN are introduced in this manuscript. The triple cable lasso technique passes 2 cerclage cables transversely through the cortex and then the nail hole, with a third cable clamping the first 2 to the outer cortex. The contoured locking plate technique bends a locking plate to fit over the protruding distal tip of the nail, locks a screw in the plate which threads the distal nail hole, and then locks the plate to the bone with unicortical screws.
    Type of Medium: Online Resource
    ISSN: 0885-9698
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2055188-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...