    In: Journal of Clinical Neurophysiology, Ovid Technologies (Wolters Kluwer Health), Vol. 34, No. 2 ( 2017-03), p. 168-173
    Abstract: The goal of the project is to determine characteristics of academic neurophysiologist EEG interpreters (EEGers), which predict good interrater agreement (IRA) and to determine the number of EEGers needed to develop an ideal standardized testing and training data set for epileptiform transient (ET) detection algorithms. Methods: A three-phase scoring method was used. In phase 1, 19 EEGers marked the location of ETs in two hundred 30-second segments of EEG from 200 different patients. In phase 2, EEG events marked by at least 2 EEGers were annotated by 18 EEGers on a 5-point scale to indicate whether they were ETs. In phase 3, a third opinion was obtained from EEGers on any inconsistencies between phase 1 and phase 2 scoring. Results: The IRA for the 18 EEGers was only fair. A select group of the EEGers had good IRA and the other EEGers had low IRA. Board certification by the American Board of Clinical Neurophysiology was associated with better IRA performance but other board certifications, years of fellowship training, and years of practice were not. As the number of EEGers used for scoring is increased, the amount of change in the consensus opinion decreases steadily and is quite low as the group size approaches 10. Conclusions: The IRA among EEGers varies considerably. The EEGers must be tested before use as scorers for ET annotation research projects. The American Board of Clinical Neurophysiology certification is associated with improved performance. The optimal size for a group of experts scoring ETs in EEG is probably in the 6 to 10 range.
    Type of Medium: Online Resource
    ISSN: 0736-0258
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2017
    detail.hit.zdb_id: 2065729-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2016
    In:  Journal of Clinical Neurophysiology Vol. 33, No. 6 ( 2016-12), p. 530-537
    In: Journal of Clinical Neurophysiology, Ovid Technologies (Wolters Kluwer Health), Vol. 33, No. 6 ( 2016-12), p. 530-537
    Abstract: This purpose of this study was to evaluate the usefulness of a prototype battery-powered dry electrode system (DES) EEG recording headset in Veteran patients by comparing it with standard EEG. Methods: Twenty-one Veterans had both a standard electrode system recording and DES recording in nine different patient states at the same encounter. Setup time, patient comfort, and subject preference were measured. Three experts performed technical quality rating of each EEG recording in a blinded fashion using the web-based EEGnet system. Power spectra were compared between DES and standard electrode system recordings. Results: The average time for DES setup was 5.7 minutes versus 21.1 minutes for standard electrode system. Subjects reported that the DES was more comfortable during setup. Most subjects (15 of 21) preferred the DES. On a five-point scale (1—best quality to 5—worst quality), the technical quality of the standard electrode system recordings was significantly better than for the DES recordings, at 1.25 versus 2.41 ( P 〈 0.0001). But experts found that 87% of the DES EEG segments were of sufficient technical quality to be interpretable. Conclusions: This DES offers quick and easy setup and is well tolerated by subjects. Although the technical quality of DES recordings was less than standard EEG, most of the DES recordings were rated as interpretable by experts. Significance: This DES, if improved, could be useful for a telemedicine approach to outpatient routine EEG recording within the Veterans Administration or other health system.
    Type of Medium: Online Resource
    ISSN: 0736-0258
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2016
    detail.hit.zdb_id: 2065729-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Journal of Clinical Neurophysiology, Ovid Technologies (Wolters Kluwer Health), Vol. 35, No. 5 ( 2018-09), p. 375-380
    Abstract: The goal of the study was to measure the performance of academic and private practice (PP) neurologists in detecting interictal epileptiform discharges in routine scalp EEG recordings. Methods: Thirty-five EEG scorers (EEGers) participated (19 academic and 16 PP) and marked the location of ETs in 200 30-second EEG segments using a web-based EEG annotation system. All participants provided board certification status, years of Epilepsy Fellowship Training (EFT), and years in practice. The Persyst P13 automated IED detection algorithm was also run on the EEG segments for comparison. Results: Academic EEGers had an average of 1.66 years of EFT versus 0.50 years of EFT for PP EEGers ( P 〈 0.0001) and had higher rates of board certification. Inter-rater agreement for the 35 EEGers was fair. There was higher performance for EEGers in academics, with at least 1.5 years of EFT, and with American Board of Clinical Neurophysiology and American Board of Psychiatry and Neurology-E specialty board certification. The Persyst P13 algorithm at its default setting (perception value = 0.4) did not perform as well at the EEGers, but at substantially higher perception value settings, the algorithm performed almost as well human experts. Conclusions: Inter-rater agreement among EEGers in both academic and PP settings varies considerably. Practice location, years of EFT, and board certification are associated with significantly higher performance for IED detection in routine scalp EEG. Continued medical education of PP neurologists and neurologists without EFT is needed to improve routine scalp EEG interpretation skills. The performance of automated detection algorithms is approaching that of human experts.
    Type of Medium: Online Resource
    ISSN: 0736-0258
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2018
    detail.hit.zdb_id: 2065729-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Journal of Clinical Neurophysiology, Ovid Technologies (Wolters Kluwer Health), Vol. 28, No. 2 ( 2011-04), p. 178-184
    Type of Medium: Online Resource
    ISSN: 0736-0258
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2011
    detail.hit.zdb_id: 2065729-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...