GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (2)
  • Gleason, Thomas G.  (2)
  • Harrison, J. Kevin  (2)
Material
Publisher
  • Ovid Technologies (Wolters Kluwer Health)  (2)
Language
Years
  • 1
    In: Circulation: Cardiovascular Interventions, Ovid Technologies (Wolters Kluwer Health), Vol. 9, No. 9 ( 2016-09)
    Abstract: The risk for stroke after transcatheter aortic valve replacement (TAVR) is an important concern. Identification of predictors for stroke is likely to be a critical factor aiding patient selection and management as TAVR use becomes widespread. Methods and Results— Patients enrolled in the CoreValve US Extreme Risk and High Risk Pivotal Trials or Continued Access Study treated with the self-expanding CoreValve bioprosthesis were included in this analysis. The 1-year stroke rate after TAVR was 8.4%. Analysis of the stroke hazard rate identified an early phase (0–10 days; 4.1% of strokes) and a late phase (11–365 days; 4.3% of strokes). Baseline predictors of early stroke included National Institutes of Health stroke scale score 〉 0, prior stroke, prior transient ischemic attack, peripheral vascular disease, absence of prior coronary artery bypass surgery, angina, low body mass index ( 〈 21 kg/m 2 ), and falls within the past 6 months. Significant procedural predictors were total time in the catheterization laboratory or operating room, delivery catheter in the body time, rapid pacing used during valvuloplasty, and repositioning of the prosthesis. Predictors of stroke between 11 and 365 days were small body surface area, severe aortic calcification, and falls within the past 6 months. There were no significant imaging predictors of early or late stroke. Conclusions— Predictors of early stroke after TAVR included clinical and procedural factors; predictors of later stroke were limited to patient but not anatomic characteristics. These findings indicate that further refinement of imaging to identify anatomic factors predisposing to embolization may help improve stroke prediction in patients undergoing TAVR. Clinical Trial Registrations— URL: http://www.clinicaltrials.gov . Unique identifiers: NCT01240902, NCT01531374.
    Type of Medium: Online Resource
    ISSN: 1941-7640 , 1941-7632
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2016
    detail.hit.zdb_id: 2450801-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Circulation: Cardiovascular Interventions, Ovid Technologies (Wolters Kluwer Health), Vol. 9, No. 7 ( 2016-07)
    Abstract: Multidetector computed tomography is useful for determining the appropriate transcatheter heart valve (THV) size in patients with severe aortic stenosis who are suboptimal surgical candidates. The relationship between adherence to the recommended CoreValve sizing algorithm and clinical outcomes is not known. Methods and Results— We evaluated 1023 patients with severe aortic stenosis deemed high or extreme risk for surgery treated with the CoreValve THV. All patients underwent preprocedural multidetector computed tomography, and the scans were reviewed at a central analysis center using standardized software. Compliance to a recommended sizing algorithm was used to identify patients with below-range, in-range, and above-range THV sizing. A device annular sizing ratio (DAR) was also calculated based on the native annulus perimeter and perimeter of the selected THV. Clinical end points included the presence of paravalvular aortic regurgitation evaluated by an independent echocardiographic laboratory. Adherence to the sizing algorithm was highest with a 31-mm THV (92.6%) and lowest with the 23-mm THV (38.5%). Below-range sizing was associated with a higher rate of moderate or severe paravalvular aortic regurgitation (15.3%) than in-range (6.5%) or above-range (10.0%; P 〈 0.001) sizing. Higher DARs were associated with lower rates of moderate or severe paravalvular aortic regurgitation: DAR ≤10%, 17.6%; DAR 10% to 15%, 9.9%; DAR 15% to 20%, 6.3%; and DAR 〉 20%, 4.9%; P 〈 0.001. There was no increase in clinical events associated with higher DARs. Conclusions— Adherence to a sizing algorithm guided by multidetector computed tomography resulted in lower rates of paravalvular aortic regurgitation after self-expanding transcatheter valve replacement without an increase in complications. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01240902.
    Type of Medium: Online Resource
    ISSN: 1941-7640 , 1941-7632
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2016
    detail.hit.zdb_id: 2450801-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...