GLORIA

GEOMAR Library Ocean Research Information Access

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Fahlenkamp, Ute Lina  (1)
  • Hamm, Bernd  (1)
  • Lembcke, Alexander  (1)
  • Wagner, Moritz  (1)
Materialart
Verlag/Herausgeber
Person/Organisation
Sprache
Erscheinungszeitraum
Fachgebiete(RVK)
  • 1
    In: Acta Radiologica, SAGE Publications, Vol. 59, No. 2 ( 2018-02), p. 161-169
    Kurzfassung: Computed tomography (CT) of the left atrium (LA) is performed prior to pulmonary vein isolation (PVI) to improve success of circumferential ablation for atrial fibrillation. The ablation procedure itself exposes patients to substantial radiation doses, therefore radiation dose reduction in pre-ablational imaging is of concern. Purpose To assess and compare diagnostic performance of low-radiation dose preprocedural CT in patients scheduled for PVI using two types of reconstruction algorithms. Material and Methods Forty-six patients (61 ± 10 years) scheduled for PVI were enrolled in this study irrespective of body-mass-index or cardiac rhythm at examination. An electrocardiographically triggered dual-source CT scan was performed. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. Images were integrated into an electroanatomic mapping (EAM) system. Subjective image quality was scored independently by two readers on a five-point scale for both reconstruction algorithms (1 = excellent to 5 = non-diagnostic). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose were calculated. Results Data acquisition and EAM integration were successful in all patients. Median image quality score was 1 for both FBP (quartiles = 1, 1.62; range = 1–3) and IR (quartiles = 1, 1.5; range = 1–3). Mean SNR was 7.61 ± 2.14 for FBP and 9.02 ± 2.69 for IR. Mean CNR was 5.92 ± 1.80 for FBP and 6.95 ± 2.29 for IR. Mean effective radiation dose was 0.3 ± 0.1 mSv. Conclusion At a radiation dose of 0.3 ± 0.1 mSv, high-pitch dual-source CT yields LA images of consistently high quality using both FBP and IR. IR raises SNR and CNR without significantly improving subjective image quality.
    Materialart: Online-Ressource
    ISSN: 0284-1851 , 1600-0455
    RVK:
    Sprache: Englisch
    Verlag: SAGE Publications
    Publikationsdatum: 2018
    ZDB Id: 2024579-8
    Standort Signatur Einschränkungen Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...