GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • S. Karger AG  (2)
  • Doellinger, Felix  (2)
  • 1
    In: Respiration, S. Karger AG, Vol. 101, No. 4 ( 2022), p. 408-416
    Abstract: 〈 b 〉 〈 i 〉 Background: 〈 /i 〉 〈 /b 〉 Endobronchial valve therapy has proven to reduce lung hyperinflation and decrease disease burden in patients with severe lung emphysema. Exclusion of collateral ventilation (CV) of the targeted lobe by using an endobronchial assessment system (Chartis; PulmonX, Drive Redwood City, CA, USA) in combination with software-based fissure integrity analysis (FCS [fissure completeness score]) of computed tomography scans of the lung are established tools to select appropriate patients for endobronchial valve treatment. So far, there is no conclusive evidence if the ventilation mode during bronchoscopy impacts the outcome of Chartis assessments. 〈 b 〉 〈 i 〉 Methods: 〈 /i 〉 〈 /b 〉 Patients with Chartis assessments and software-based quantification of FCS (StratX; PulmonX, Drive Redwood City, CA, USA) were enrolled in this retrospective study. During bronchoscopy, pulmonary fissure integrity was evaluated with the Chartis assessment system in each patient first under spontaneous breathing and subsequently under high-frequency (HF) jet ventilation. 〈 b 〉 〈 i 〉 Results: 〈 /i 〉 〈 /b 〉 In total, 102 patients were analyzed. Four Chartis phenotypes CV positive (CV+), CV negative (CV−), low flow, and low plateau in spontaneous breathing and HF jet ventilation were identified. The frequency of each Chartis phenotype per lobe was similar in both settings. When comparing Chartis assessments in spontaneous breathing and HF jet ventilation, there was an overall good concordance rate for all analyzed fissures. In agreement, receiver operating characteristic analysis of the FCS showed an almost similar prediction for CV+ and CV− status independent of the ventilation modes. 〈 b 〉 〈 i 〉 Conclusion: 〈 /i 〉 〈 /b 〉 Chartis assessment in spontaneous breathing and HF jet ventilation had similar rates in detecting CV in lung emphysema. Our results suggest that both modes are equivalent for the assessment of CV.
    Type of Medium: Online Resource
    ISSN: 0025-7931 , 1423-0356
    Language: English
    Publisher: S. Karger AG
    Publication Date: 2022
    detail.hit.zdb_id: 1464419-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Respiration, S. Karger AG, Vol. 102, No. 4 ( 2023), p. 296-307
    Abstract: Endoscopic lung volume reduction procedure with valves is a well-studied treatment option for advanced lung emphysema to target lung hyperinflation in carefully selected patients with COPD. Before valve implantation, collateral ventilation (CV) of the target lobe needs to be assessed to obtain an optimal treatment effect. The analysis of CV according to current standards occurs via an in vivo assessment with the Chartis®system (PulmonX Inc., Redwood City, CA, USA) and a computed tomography (CT) scan of the thorax with interlobar fissure analysis. The focus of this review is to provide detailed information about the Chartis®procedure and interpretation of Chartis® phenotypes. As a main tool in the assessment of CV and being a safe procedure, the Chartis® assessment should be performed by default to confirm interlobar fissure analysis in most emphysema patients. Based on the obtained results, lung volume reduction therapy options should be discussed in an interdisciplinary emphysema conference.
    Type of Medium: Online Resource
    ISSN: 0025-7931 , 1423-0356
    Language: English
    Publisher: S. Karger AG
    Publication Date: 2023
    detail.hit.zdb_id: 1464419-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...