GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • S. Karger AG  (2)
  • Chen, Chien-Jen  (2)
Material
Publisher
  • S. Karger AG  (2)
Language
Years
Subjects(RVK)
  • 1
    In: Cardiology, S. Karger AG, Vol. 104, No. 4 ( 2005), p. 171-175
    Abstract: The study population consisted of 16 patients with rheumatic mitral stenosis undergoing percutaneous transluminal mitral valvuloplasty (group 1). The plasma levels of tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10) in the femoral vein and the right and left atria before valvuloplasty were determined by ELISA. Additionally, we measured plasma concentrations of TNF-α and IL-10 in the venous blood obtained from 19 control patients, including 12 healthy volunteers in sinus rhythm (group 2) and 7 patients in permanent lone atrial fibrillation (group 3). The venous plasma levels of TNF-α were significantly elevated in group 1 patients compared with group 2 patients (p 〈 0.002). Correlation analysis demonstrated that there was a significantly direct relationship between the plasma TNF-α and IL-10 concentrations in the left atrial, right atrial and peripheral venous blood (p 〈 0.008, r = 0.640; p 〈 0.04, r = 0.538; p 〈 0.03, r = 0.571, respectively). In conclusion, the plasma concentrations of TNF-α of patients with rheumatic mitral stenosis were significantly higher than those of healthy volunteers. In addition, there was a significantly direct relationship between the soluble TNF-α and IL-10 concentrations in the atrial and peripheral venous blood, indicating a balance between circulating TNF-α and IL-10 levels in patients with rheumatic mitral stenosis.
    Type of Medium: Online Resource
    ISSN: 0008-6312 , 1421-9751
    RVK:
    Language: English
    Publisher: S. Karger AG
    Publication Date: 2005
    detail.hit.zdb_id: 1482041-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Cardiology, S. Karger AG, Vol. 102, No. 4 ( 2004), p. 206-214
    Abstract: 〈 i 〉 Background: 〈 /i 〉 Distal embolization and no reflow are likely during primary percutaneous coronary intervention (PCI) on the large infarct-related artery (IRA), which mostly contains high-burden thrombus formation (HBTF) and plaque burden. Mechanical devices to prevent distal atheroembolism may be of importance for preserving reperfusion and microvascular integrity in IRA. 〈 i 〉 Methods and Results: 〈 /i 〉 Between May 2002 and December 2002, transradial application (TRA) of the PercuSurge GuardWire™ device with 7-french arterial sheath was performed in 39 consecutive patients who experienced early ( 〉 12 h and ≤7 days) or recent ( 〉 7 days and 〈 14 days) myocardial infarction (MI) associated with large IRA (vessel size ≧3.5 mm with HBTF; group 1). Between January 2001 and April 2002, 64 consecutive patients who had early or recent MI associated with HBTF in IRA of a vessel size ≧3.5 mm received TRA of PCI with adjunctive tirofiban therapy but without using the adjunctive PercuSurge GuardWire device (group 2). The angiographic and clinical outcomes of both groups were compared in a chronologically consecutive manner. The procedural success rate and post-PCI myocardial blush grades were significantly higher in group 1 than in group 2 patients (all p values 〈 0.05), whereas a combined incidence of vascular and bleeding complications and 30-day major adverse cardiac events (defined as death, reinfarction and repeated PCI of IRA) were significantly higher in group 2 than in group 1 patients (all p values 〈 0.05). 〈 i 〉 Conclusions: 〈 /i 〉 Our data suggested that TRA using the PercuSurge GuardWire device during PCI for patients with early or recent MI and HBTF in IRA was safe and feasible. This mechanical device provided more additional benefit to patients in this clinical setting than a combination of conventional PCI and tirofiban therapy.
    Type of Medium: Online Resource
    ISSN: 0008-6312 , 1421-9751
    RVK:
    Language: English
    Publisher: S. Karger AG
    Publication Date: 2004
    detail.hit.zdb_id: 1482041-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...