GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Neurosurgical Focus, Journal of Neurosurgery Publishing Group (JNSPG), Vol. 54, No. 5 ( 2023-05), p. E4-
    Abstract: Ruptured blister, dissecting, and iatrogenic pseudoaneurysms are rare pathologies that pose significant challenges from a treatment standpoint. Endovascular treatment via flow diversion represents an increasingly popular option; however, drawbacks include the requirement for dual antiplatelet therapy and the potential for thromboembolic complications, particularly acute complications in the ruptured setting. The Pipeline Flex embolization device with Shield Technology (PED-Shield) offers reduced material thrombogenicity, which may aid in the treatment of ruptured internal carotid artery pseudoaneurysms. METHODS The authors conducted a multi-institution, retrospective case series to determine the safety and efficacy of PED-Shield for the treatment of ruptured blister, dissecting, and iatrogenic pseudoaneurysms of the internal carotid artery. Clinical, radiographic, treatment, and outcomes data were collected. RESULTS Thirty-three patients were included in the final analysis. Seventeen underwent placement of a single device, and 16 underwent placement of two devices. No thromboembolic complications occurred. Four patients were maintained on aspirin alone, and all others were treated with long-term dual antiplatelet therapy. Among patients with 3-month follow-up, 93.8% had a modified Rankin Scale score of 0–2. Complete occlusion at follow-up was observed in 82.6% of patients. CONCLUSIONS PED-Shield represents a new option for the treatment of ruptured blister, dissecting, and iatrogenic pseudoaneurysms of the internal carotid artery. The reduced material thrombogenicity appeared to improve the safety of the PED-Shield device, as this series demonstrated no thromboembolic complications even among patients treated with only single antiplatelet therapy. The efficacy of PED-Shield reported in this series, particularly with placement of two devices, demonstrates its potential as a first-line treatment option for these pathologies.
    Type of Medium: Online Resource
    ISSN: 1092-0684
    Language: Unknown
    Publisher: Journal of Neurosurgery Publishing Group (JNSPG)
    Publication Date: 2023
    detail.hit.zdb_id: 2026589-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...