GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Beer, Meinrad  (1)
  • 2010-2014  (1)
  • Medicine  (1)
Material
Publisher
Language
Years
  • 2010-2014  (1)
Year
Subjects(RVK)
  • Medicine  (1)
RVK
  • 1
    In: Acta Radiologica, SAGE Publications, Vol. 55, No. 2 ( 2014-03), p. 155-160
    Abstract: Late enhancement (LE) imaging is increasingly used for diagnosis of non-ischemic cardiomyopathy. However, the mostly patchy appearance of LE in this context may reduce the reproducibility of LE measurement. Purpose To report intra- and inter-observer variabilities of LE measurements in Fabry disease using manual and semi-automated quantification. Material and Methods Twenty MRI data-sets of male patients aged 44 ± 7 years were analyzed twice (interval 12 months) by one observer and additionally once by a second observer. Left ventricular (LV) parameters were determined using cine MRI. Gradient-echo LE images were analyzed by manual planimetry and by a semi-automatic prototype software. Variabilities were determined by Bland-Altman analyses and additionally intra-class correlation coefficient (ICC) values were calculated to survey intra- and inter-observer reproducibility. Results The amount of LE was 5.2 ± 5.1 mL or 2.8 ± 2.6 % of LV mass (observer 2). LE was detected predominantly intramurally in a patchy pattern. All patients had LE restricted to the basal infero-lateral parts of the LV. The extent of LE correlated to LV mass (207 ± 70 g, P  〈  0.05, r = 0.6). The intra- and inter-observer variabilities were −0.6 to 1.0 mL and −0.7 to 1.6 mL, respectively (95% confidence intervals). ICC values were 0.981–0.999. The semi-automatic software allowed quantification of LE areas in all patients. The comparison of LE amount determined by semi-automatic software versus manual planimetry yielded an intra-observer variability ranging from −1.9 to 2.3 mL. Conclusion Semi-automatic planimetry of patchy LE in patients with Fabry disease is feasible. The determined intra- and inter-observer variabilities for manual and semi-automatic planimetry were in the range of 20–40% of LE amount with high ICC values.
    Type of Medium: Online Resource
    ISSN: 0284-1851 , 1600-0455
    RVK:
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2014
    detail.hit.zdb_id: 2024579-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...