GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Aretzweiler, Gudrun  (1)
  • Austin, Harrison  (1)
  • 1
    In: Hepatology Communications, Ovid Technologies (Wolters Kluwer Health), Vol. 4, No. 7 ( 2020-07), p. 983-997
    Abstract: Despite effective hepatitis B virus (HBV)‐DNA suppression, HBV RNA can circulate in patients receiving nucleoside/nucleotide analogues (NAs). Current assays quantify HBV DNA by either real‐time polymerase chain reaction (PCR), which uses DNA polymerase, or transcription‐mediated amplification, which uses reverse‐transcriptase (RT) and RNA polymerase. We assessed the effect of RT capability on HBV‐DNA quantification in samples from three cohorts, including patients with quantified HBV RNA. We compared the HBV‐DNA levels by real‐time PCR (cobas HBV, Roche 6800/8800; Xpert HBV, Cepheid), transcription‐mediated amplification (Aptima HBV, Hologic), and real‐time PCR with added RT capability (cobas HBV+RT). In the first cohort (n = 45) followed over 192 weeks of NA therapy, on‐treatment HBV‐DNA levels were higher with cobas HBV+RT than cobas HBV (mean difference: 0.14 log 10 IU/mL). In a second cohort (n = 50) followed over 96 weeks of NA therapy, HBV‐DNA viral load was significantly higher with the cobas HBV+RT and Aptima HBV compared with the cobas HBV test at all time points after initiation of NA therapy (mean difference: 0.65‐1.16 log 10 IU/mL). A clinically significant difference was not detected between the assays at baseline. In a third cohort (n = 53), after a median of 2.2 years of NA therapy, we detected HBV RNA (median 5.6 log 10 copies/mL) in 23 patients (43.4%). Median HBV‐DNA levels by Aptima HBV were 2.4 versus less than 1 log 10 IU/mL in samples with HBV RNA and without HBV RNA, respectively ( P  = 0.0006). In treated patients with HBV RNA, Aptima HBV measured higher HBV‐DNA levels than Xpert HBV and cobas HBV. Conclusion: Tests including an RT step may overestimate HBV DNA, particularly in samples with low viral loads as a result of NA therapy. This overestimation is likely due to amplification of HBV RNA and may have an impact on clinical decisions.
    Type of Medium: Online Resource
    ISSN: 2471-254X , 2471-254X
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2881134-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...