    In: Journal of International Medical Research, SAGE Publications, Vol. 46, No. 3 ( 2018-03), p. 965-974
    Abstract: The expression level of monocyte chemoattractant protein-1 (MCP-1) is increased in atherosclerotic regions, inducing monocyte migration to the blood vessel wall. Although the serum MCP-1 concentration is higher in patients with than without cardiovascular disease, the precise correlations between the serum MCP-1 concentration and factors associated with smoking and atherosclerosis are unknown. Methods The serum MCP-1 concentration was measured using an enzyme-linked immunosorbent assay in 207 consecutive smokers who visited our smoking cessation clinic. Results Sex-adjusted analysis of smokers revealed that the MCP-1 concentration was positively correlated with age ( β = 0.311), smoking duration ( β = 0.342), systolic blood pressure ( β = 0.225), and diastolic blood pressure ( β = 0.137) but not with the body mass index. Multivariate regression analysis showed that smoking duration and systolic blood pressure were independent determinants of the MCP-1 concentration. Conclusions The MCP-1 concentration was positively correlated with blood pressure among smokers. Long-term smokers with high blood pressure may be more susceptible to plaque rupture at atherosclerotic lesion sites.
    Type of Medium: Online Resource
    ISSN: 0300-0605 , 1473-2300
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2018
    detail.hit.zdb_id: 2082422-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Japanese Clinical Medicine, SAGE Publications, Vol. 2 ( 2011-01), p. JCM.S6254-
    Abstract: Lymphocytic hypophysitis is divided into three forms according to the involved tissues, lymphocytic adenohypophysitis, lymphocytic infundibulo-neurohypophysitis, and lymphocytic panhypophysitis (LPH). The term LPH was first proposed by us in 1995, although its entity and pathogenesis still remain controversial. Here we report five cases of LPH, who visited our clinics during 1994 to 2009. All cases were female of 20 to 77 years of age, and one case was associated with pregnancy. They presented with polyuria (n = 4), headache (n = 3), general malaise, polydipsia (n = 2), blunted vision, diplopia, amenorrhea or appetite loss (n = 1). Magnetic resonance imaging showed the pituitary swelling, the thickened stalk, the loss of the T1 hyperintense neurohypophysis (n = 4), or the atrophic pituitary (n = 1). Endocrinological examinations revealed deficiencies of TSH, ADH in all cases, GH, ACTH in three cases, LH, PRL in two cases, and FSH in one case, respectively. The severity of ADH deficiency varied among the cases. Anti-pituitary antibody was not detected in the cases examined. The biopsy of the pituitary lesions was performed except for one case, all of which revealed the diffuse lymphocytic infiltration. These results suggest that LPH is characterized by the female predominance, the atypical patterns of anterior pituitary hormone deficiencies and the variable degrees of diabetes insipidus in Japanese.
    Type of Medium: Online Resource
    ISSN: 1179-6707 , 1179-6707
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2011
    detail.hit.zdb_id: 2596434-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, SAGE Publications, Vol. 42, No. 1 ( 2005-01-01), p. 41-46
    Abstract: Background: The Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) previously recommended use of the primary calibrator (JDS Lot 1) prepared by the former Committee for Standardization of Glycohemoglobin for standardizing the measurement of haemoglobin A1c (HbA1c). Owing to the depletion of vials of Lot 1 in March 2001, the present committee certified a new reference material, Lot 2, now distributed by the Health Care Technology Foundation (HECTEF). The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, which has values assigned from within Lot 1; the Lot 1 values were consensus values based on assays by laboratories in the Japanese national quality control programme. In this study, for the purpose of international comparison and standardization, Lot 2 was assayed by the JDS reference laboratories, the National Glycoprotein Standardization Program (NGSP) in the USA, and by reference laboratories approved by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Method: The HbA1c values of JDS Lot 2 were transferred from those assigned to Lot 1 using KO500, a high-resolution HPLC method, at three laboratories approved by the JDS committee. Subsequently, vials of JDS Lot 2 were shipped to and assayed by the NGSP in the USA and 10 IFCC reference laboratories. Result: The JDS-assigned HbA1c values (from Lot 1) are 4.04 for Level 1, 5.38 for Level 2, 7.32 for Level 3, 9.88 for Level 4, and 12.63 for Level 5, all expressed as a percentage of total haemoglobin. The values obtained by NGSP and the IFCC laboratories gave the following formulas: NGSP value (%) = JDS value (%) + 0.3%; IFCC value (%) = 1.068 x JDS value (%) -1.741%. Conclusion: Although the values obtained by the IFCC laboratories are significantly lower than the values assigned to Lot 2 by the JDS, the relationship is linear. In addition, standardization of HbA1c based on JDS Lot 2 is currently at a satisfactory level in Japan. As a result, the reassignment of values for Lot 2 to agree with the IFCC values should be relatively easy and will be done after all relevant parties agree to the change.
    Type of Medium: Online Resource
    ISSN: 0004-5632 , 1758-1001
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2005
    detail.hit.zdb_id: 2041298-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, SAGE Publications, Vol. 42, No. 1 ( 2005-01-01), p. 47-50
    Abstract: Background: In 2001, the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) prepared and certified a new reference material for haemoglobin A1c (HbA1c), Lot 2. The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, although some laboratories still use the previous material (Lot 1). The values assigned to Lot 2 were based on the consensus values for Lot 1 and should give the same results. Therefore, there should be no difference in the measured values no matter which calibrators are used. The Committee conducted a domestic survey in order to confirm this relationship. Method: In November 2002, four samples for HbA1c assay were sent to 795 laboratories as part of a national survey in Japan. Assays were performed using the laboratories' routine clinical methods. The coefficients of variation (CVs) of the reported values from all laboratories for the samples were calculated in order to determine the current level of standardization in Japan. Results: The overall CVs in the measured values for the four samples ranged from 2.7% to 4.0%. Values from laboratories using calibrators based on Lots 1 and 2 were similar. Conclusion: The present state of standardization for the routine measurement of HbA1c in Japan, as indicated by the 2002 survey, is excellent. This should aid in the eventual conversion of Lot 2 to IFCC-based values from the results of the 2002 national HbA1c survey.
    Type of Medium: Online Resource
    ISSN: 0004-5632 , 1758-1001
    Language: English
    Publisher: SAGE Publications
    Publication Date: 2005