GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Online Resource  (6)
  • Ovid Technologies (Wolters Kluwer Health)  (6)
  • Hsiao, Fu-Yin  (6)
Material
  • Online Resource  (6)
Publisher
  • Ovid Technologies (Wolters Kluwer Health)  (6)
Language
Years
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Annals of Plastic Surgery Vol. 88, No. 1s ( 2022-3), p. S78-S84
    In: Annals of Plastic Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 88, No. 1s ( 2022-3), p. S78-S84
    Abstract: The most widely used method for breast reconstruction in Taiwan is alloplastic breast reconstruction, and traditionally, it can be categorized into immediate or delayed, single-stage or 2-stage procedures. We evaluated clinical outcomes and analyzed patients' self-reported satisfaction and quality of life after alloplastic breast reconstruction based on a previous preliminary study. Patient and Methods The patients who underwent primary alloplastic breast reconstruction after mastectomy were recruited in 2006 to 2020 at a single institute in Taiwan. The assessment of clinical outcomes was conducted by retrospective chart review and risk analysis. The patients also completed the BREAST-Q, a condition-specific patient-reported outcome measure, at least 6 months after treatment. Results A total of 237 patients with 247 reconstructed breasts were enrolled in this study. The demographics showed that 205 (83%) were reconstructed using a 2-stage tissue expander-based procedure and 42 (17%) were 1-stage direct-to-implant reconstructions. The mean follow-up time was 79.5 months. The clinical assessment revealed that the overall complication rate was 34%, with infection being the most common (21 patients; 8%). According to risk analysis, smoking (odds ratio, 7.626; 95% confidence interval, 1.56–37.30; P = 0.012), and nipple-sparing mastectomy (odds ratio, 3.281; 95% confidence interval, 1.54–6.99; P = 0.002) were significant risk factors for overall complications. The questionnaire response rate was 38% (94 of 247), at least 6 months after treatment. The total mean score was 69.78. Conclusions At a single institute in Taiwan from 2006 to 2020, alloplastic breast reconstruction, either single- or 2-stage, have acceptable complication rate and good postoperative satisfaction based on patient-reported outcomes. Both patient- and surgery-related factors presented as significant risk factors. Precise patient selection and comprehensive discussion between the patient and physician may play the important role to achieve optimal aesthetic outcomes.
    Type of Medium: Online Resource
    ISSN: 1536-3708 , 0148-7043
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2063013-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Journal of the Chinese Medical Association, Ovid Technologies (Wolters Kluwer Health), Vol. 82, No. 9 ( 2019-09), p. 732-739
    Abstract: Accurate assessment of breast volume is an essential component of preoperative planning in one-stage immediate breast reconstruction (IBR) for achieving breast symmetry and a satisfactory cosmetic outcome. In this study, we compared breast volume estimation using three-dimensional (3D) surface imaging with magnetic resonance imaging (MRI) to determine the accuracy of breast volume measurements. Further, a 3D printing mold for facilitating autologous breast reconstruction intraoperatively is described. Methods: Patients scheduled to therapeutic or prophylactic mastectomy with one-stage IBR, either by autologous tissue transfer or direct implant, from 2016 to 2019, were enrolled in this study. 3D surface image and MRI were performed to evaluate breast volume and shape. The results were validated by the water displacement volume of the mastectomy specimen. Finally, a 3D printing mold was designed for breast reconstruction with autologous tissue. Results: Nineteen women who were scheduled to have 20 mastectomies (18 unilateral and one bilateral) were included. There was a strong linear association between breast volume measured using the two different methods and water displacement of mastectomy specimens when a Pearson correlation was used (3D surface image: r = 0.925, p 〈 0.001; MRI: r = 0.915, p 〈 0.001). Bland-Altman plots demonstrated no proportional bias between the assessment methods. The coefficient of variation was 52.7% for 3D surface imaging and 59.9% for MRI. The volume of six breasts was evaluated by both measurements and the intraclass correlation coefficient was 0.689 for 3D surface image ( p = 0.043) and 0.743 for MRI ( p = 0.028). Conclusion: Using 3D surface image to evaluate breast shape and volume is a quick, effective, and convenient method. The accuracy, reproducibility, and reliability of 3D surface imaging were comparable with MRI in our study. In addition, 3D-printed molds can achieve better symmetry and aesthetic outcomes in immediate autologous breast reconstructions.
    Type of Medium: Online Resource
    ISSN: 1726-4901
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2019
    detail.hit.zdb_id: 2202774-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2020
    In:  Journal of the Chinese Medical Association Vol. 83, No. 6 ( 2020-06), p. 585-585
    In: Journal of the Chinese Medical Association, Ovid Technologies (Wolters Kluwer Health), Vol. 83, No. 6 ( 2020-06), p. 585-585
    Type of Medium: Online Resource
    ISSN: 1726-4901
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2202774-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Annals of Plastic Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 88, No. 1s ( 2022-3), p. S39-S43
    Abstract: Patients who had reconstruction for head and neck cancer usually have long duration of postoperative sedation and intensive care. This is due to the complex nature of large-area soft tissue defect surgeries and upper respiratory tract infections associated with them. Postoperative pulmonary complications are common in these patients. In this study, we analyzed the risk factors and the relationship between postoperative complications and the duration of sedation to improve the patients' recovery process after free flap reconstruction for head and neck surgery. Materials and Methods This was a retrospective study that included 188 patients who had head and neck surgery with free flap reconstruction in 2011 (traditional recovery group) and 2018 (early recovery group). Postoperative recovery events were compared between the 2 groups. Complications such as pneumonia, wound infection, vascular thrombosis, and bleeding were also analyzed. Results The results showed that the early recovery group had a shorter duration of sedation ( P 〈 0.001), shorter duration of intensive care unit stay ( P = 0.05), more rapid ventilator weaning ( P 〈 0.001), and fewer pneumonia events (8.8% vs 39.1%) than the traditional recovery group. Wound- and vessel-related complications were not affected by the duration of sedation. Conclusions Our study demonstrated that shortening the duration of postoperative sedation can effectively decrease the length of intensive care unit stay and reduce postoperative incidence of pneumonia without increasing wound- and vessel-related complications.
    Type of Medium: Online Resource
    ISSN: 1536-3708 , 0148-7043
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2063013-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Annals of Plastic Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 88, No. 1s ( 2022-3), p. S92-S98
    Abstract: Direct-to-implant (DTI) breast reconstruction is one of the immediate implant-based breast reconstruction methods. If the amount of soft tissue (eg, muscle or fascia) is insufficient to completely cover the implant, biological scaffold or acellular dermal matrix can be safely used for implant coverage. In this study, we used an acellular porcine small intestinal submucosa (SIS) mesh (Biodesign; Cook Medical Inc, Bloomington, IN) for DTI reconstruction to explore the impact of its use on breast reconstruction results. Methods We retrospectively assessed cases involving DTI reconstruction at Taipei Veterans General Hospital from 2015 to 2019. Women, 18 years or older, who underwent immediate DTI reconstruction after mastectomy were included in the study. Mastectomy may have been performed because of therapeutic or prophylactic reasons. Patients who did and did not use SIS mesh for reconstruction were studied separately, and the 2 groups were compared in terms of clinical outcomes and complications. The validated, self-administered BREAST-Q Reconstruction Module version 2.0 survey was used to evaluate health-related quality of life and satisfaction among patients who underwent breast reconstruction. Results A total of 30 DTI breast reconstructions were enrolled. The mean age was 49.2 years, and the mean body mass index was 22.3 kg/m 2 . The mean postoperative follow-up duration was 17.1 months. Nipple-sparing mastectomy was performed for 26 cases (86.7%), and DTI breast reconstructions using SIS mesh for implant coverage were done in 14 cases (46.7%). The overall complication rate was 53.3% in 30 reconstructions, with nipple complications being the most common complication. The non-SIS and SIS-using groups had a similar overall complication rate postoperatively. As for the quality-of-life assessment, the SIS group obtained a higher score on BREAST-Q than those for whom SIS was not used. Conclusions Porcine SIS mesh might be a safe and effective alternative to biological scaffolds in immediate 1-stage implant-based breast reconstruction to improve the quality of life after surgery.
    Type of Medium: Online Resource
    ISSN: 1536-3708 , 0148-7043
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2063013-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    In: Journal of the Chinese Medical Association, Ovid Technologies (Wolters Kluwer Health), Vol. 83, No. 2 ( 2020-02), p. 206-210
    Abstract: Burns that affect ≥20% of the total body surface area (TBSA) trigger a major inflammatory response in addition to capillary leakage and loss of serum proteins including albumin. Persistent hypoalbuminemia is therefore common in major burn patients. The purpose of this study was to determine whether human albumin solutions can benefit major burn patients with persistent hypoalbuminemia. Methods: We conducted a retrospective review of major burn patients with ≥20% of TBSA involved at Taipei Veterans General Hospital between January 2007 and December 2018. Thirty-eight patients were enrolled. Patient demographics, burn characteristics, fluid balance, laboratory results, and outcomes were recorded through chart review. Result: No significant differences were found in the baseline characteristics of patients who received 〈 25 mg/kg/%TBSA/day of human albumin solutions and those who received more than this amount. Renal replacement therapy, duration of mechanical ventilation, length of stay in the burn unit, and in-hospital mortality rate were not statistically different between the two groups. The serum C-reactive protein/albumin ratio was associated with in-hospital mortality ( p = 0.036). Conclusion: The administration of large amounts of albumin supplements for the correction of prolonged hypoalbuminemia in major burn patients had no significant benefits on mortality.
    Type of Medium: Online Resource
    ISSN: 1726-4901
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2202774-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...