GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (16)
  • English  (16)
  • 1
    In: Circulation: Cardiovascular Imaging, Ovid Technologies (Wolters Kluwer Health), Vol. 3, No. 1 ( 2010-01), p. 65-76
    Abstract: Background— Cardiac MRI is important in the treatment of children with congenital heart disease, but sufficient normative data are lacking. For ventricular volumes and mass, we sought to deliver reference centiles and to investigate sex effects. Methods and Results— We included 114 healthy children and adolescents, uniformly distributed spanning an age range of 4 to 20 years, as required by the Lambda-Mu-Sigma method to achieve a percentile distribution, thus avoiding arbitrary age categories. Subjects underwent axial volumetry (1.5-T scanner) using standardized 2D steady-state free-precession and flow protocols. Percentiles were computed for age 8 to 20 years (99 subjects) because breath-holds were more consistent in this group. When indexed for body surface area or height, the centile curves of ventricular volumetric parameters showed allometric increase until adolescence, when a plateau was reached, with values comparable to published adult reference data. In contrast, ventricular mass centiles increased without plateau. There was a significant sex difference, with centiles reflecting larger values in boys than in girls ( P 〈 0.05) when ventricular volumes were indexed to body surface area or height but not when indexed to weight (exception: mass). There was excellent agreement of axial and short-axis volumetry and of volumetric and flow-derived stroke volumes. Conclusions— Percentiles for ventricular volumes and mass in healthy children have been established to serve as reference values in pediatric heart disease. Significant sex differences were noted when indexing volumes to body surface area or height. Unisex centiles related to weight may be considered for chamber volumes albeit not for mass.
    Type of Medium: Online Resource
    ISSN: 1941-9651 , 1942-0080
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2010
    detail.hit.zdb_id: 2440475-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Circulation, Ovid Technologies (Wolters Kluwer Health), Vol. 103, No. 20 ( 2001-05-22), p. 2476-2482
    Abstract: Background —Blood flow can be quantified noninvasively by phase-contrast cine MRI (PC-MRI) in adults. Little is known about the feasibility of the method in children with congenital heart disease. Methods and Results —In 50 children (mean age 6.2 years, range 1.1 to 17.7 years) with an atrial- or ventricular-level shunt, blood flow rate in the great vessels was determined by PC-MRI, and the ratio of pulmonary to aortic flow (Q̇p/Q̇s) was compared with Q̇p/Q̇s by oximetry. We found a difference of 2% and a range of −20% to +26% (limits of agreement, mean±2 SD). In another 7 children with congenital heart disease but no cardiac shunting (mean age 7.9 years, range 1.3 to 13.5 years), Q̇p/Q̇s by PC-MRI was 1.02 (SD ±0.06). No difference between systemic venous and aortic flow volumes was found (range −17% to +20%, n=37). Blood flow through a secundum atrial septal defect as assessed by PC-MRI (n=24) overestimated the shunt compared with the difference between pulmonary and aortic flows. The mean difference between 3 repeated PC-MRI measurements in each location was 5.3% (SD ±4.0%, n=522), demonstrating good precision. The interobserver variability was low. The accuracy of PC-MRI was confirmed by in vitro experiments. Conclusions —Determination of Q̇p/Q̇s by PC-MRI in children is quick, safe, and reliable compared with oximetry. Systemic venous flow can be quantified by PC-MRI, whereas through-plane shunt measurement within an atrial septal defect is inaccurate.
    Type of Medium: Online Resource
    ISSN: 0009-7322 , 1524-4539
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2001
    detail.hit.zdb_id: 1466401-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    In: Hypertension, Ovid Technologies (Wolters Kluwer Health), Vol. 65, No. 2 ( 2015-02), p. 362-369
    Abstract: Aortic pulse wave velocity (aPWV), a major prognostic indicator of cardiovascular events, may be augmented in hypertension as a result of the aorta being stretched by a higher distending blood pressure or by a structural change. We used a novel technique to modulate intrathoracic pressure and thus aortic transmural pressure (TMP) to examine the variation of intrathoracic aPWV with TMP in hypertensive (n=20; mean±SD age, 52.1±15.3 years; blood pressure, 159.6±21.2/92.0±15.9 mm Hg) and normotensive (n=20; age, 55.5±11.1 years; blood pressure, 124.5±11.9/72.6±9.1 mm Hg) subjects. aPWV was measured using dual Doppler probes to insonate the right brachiocephalic artery and aorta at the level of the diaphragm. Resting aPWV was greater in hypertensive compared with normotensive subjects (897±50 cm/s versus 784±43 cm/s; P 〈 0.05). aPWV was equal in hypertensive and normotensive subjects when measured at a TMP of 96 mm Hg. However, dependence of aPWV on TMP in normotensive subjects was greater than that in hypertensive subjects (9.6±1.6 versus 3.8±0.7 cm/s per mm Hg increase in TMP, respectively, means±SEM; P 〈 0.01). This experimental behavior was best explained by a theoretical model incorporating strain-induced recruitment of stiffer fibers in normotensive subjects and fully recruited stiffer fibers in hypertensive subjects. These results explain previous contradictory findings with respect to isobaric aPWV in hypertensive compared with normotensive subjects. They suggest that hypertension is associated with a profound change in aortic wall mechanical properties possibly because of destruction of elastin leading to less strain-induced stiffening and predisposition to aortic dissection.
    Type of Medium: Online Resource
    ISSN: 0194-911X , 1524-4563
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2015
    detail.hit.zdb_id: 2094210-2
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    In: Circulation, Ovid Technologies (Wolters Kluwer Health), Vol. 144, No. Suppl_1 ( 2021-11-16)
    Abstract: Introduction: “Le Coeur en Sabot” (or the boot-shaped heart) is a radiological description of the appearance of the heart on a plain radiograph of a patient with Tetralogy of Fallot. This highlights the importance of the shape of the heart. Maladaptive remodeling is known to occur in patients with repaired Tetralogy of Fallot (rToF) due to residual lesions such as Pulmonary Regurgitant Fraction (PRF) Hypothesis: Shape and function analysis can reveal novel remodeling patterns associated with adverse events in patients with rToF Methods: Biventricular shape and function were studied in 192 patients with rToF (median age 15 years). Linear discriminative analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events (AE). AE included death, arrhythmias, and cardiac arrest (median follow-up 10 years) Results: LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular LV (decreased eccentricity), dilated (increased sphericity) LV base, increased RV apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.78). PRF did not add value, and shape changes associated with increased PRF were not predictive of AE. Conclusions: Remodeling patterns in patients with rToF are associated with AE, independent of PRF. Mechanisms leading to AE include LV basal dilation with a reduced RV apical ejection fraction. That is to say that the old descriptor, “Le Coeur en Sabot'' may also describe that shape that is adverse in rTOF. The toe of this boot would be the dilated and poorly contractile RV apex and the ankle would be the spherical LV base (Figure 1: Top Row Diastole. Middle Systole. Posterior projection (a), anatomical position (b) and superior (c). LV is green)
    Type of Medium: Online Resource
    ISSN: 0009-7322 , 1524-4539
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 1466401-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Circulation: Cardiovascular Imaging, Ovid Technologies (Wolters Kluwer Health), Vol. 4, No. 6 ( 2011-11), p. 703-711
    Abstract: The impact of gender and age on cardiac function by cardiac magnetic resonance (CMR) in repaired tetralogy of Fallot (TOF) is unknown, which limits the value of currently discussed volumetric thresholds and the accuracy of individual follow-up. Methods and Results— In a nationwide, prospective, 14-center study, 407 consecutive patients with repaired TOF (age, 17.9±8.3 years; range, 8–59 years; 226 male patients) underwent standardized CMR ventricular volumetry and flow quantification (pulmonary artery/ascending aorta). There were no sex differences for age at TOF repair, type of repair, number of prior repair palliations or reinterventions after repair, pulmonary regurgitation fraction, and maximal gradient across the right ventricular outflow tract. Biventricular volumes and mass (indexed to body surface area), available in 380 of 407 patients, respectively, were higher in male patients ( P 〈 0.003), but biventricular ejection fraction was higher in female patients ( P 〈 0.012). As opposed to reported data of healthy populations, sex-specific reference percentiles computed for an age range of 8 to 40 years (lambda-mu-sigma method) demonstrated (1) an increase of end-diastolic and end-systolic left ventricular volumes, particularly in female patients; (2) an increase of end-systolic right ventricular volumes in both sexes; and (3) a decrease of biventricular ejection fraction in male patients, whereas in female patients, only right ventricular ejection fraction decreased. Conclusions— Significant gender differences of biventricular volumes, function, and mass by CMR exist late after repair of TOF, suggesting that age and gender cannot be ignored when discussing thresholds. Gender-specific percentiles may present a more relevant framework of reference for an individual patient at a given age and suggest a gradual decline of biventricular systolic function over time. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00266188.
    Type of Medium: Online Resource
    ISSN: 1941-9651 , 1942-0080
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2011
    detail.hit.zdb_id: 2440475-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2008
    In:  Circulation: Cardiovascular Imaging Vol. 1, No. 2 ( 2008-09), p. 141-147
    In: Circulation: Cardiovascular Imaging, Ovid Technologies (Wolters Kluwer Health), Vol. 1, No. 2 ( 2008-09), p. 141-147
    Abstract: Background— Anatomic and functional observations suggest that the right ventricle (RV) can be analyzed in terms of its inlet, apical trabecular, and outlet components. Our study was designed to evaluate the regional adaptation of these components to different conditions of loading, with additional analysis of the surgical techniques used for primary repair. Methods and Results— We studied prospectively 45 patients with tetralogy of Fallot (age, 20.5�8.1 years) and 24 control subjects (age, 20.1�5.8 years). All subjects were studied by using cardiac MRI. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), and ejection fraction (EF) were determined for the overall RV and separately for its inlet, apical trabecular, and outlet components. The patients had pulmonary regurgitant fractions of 33.2�11.1%, and RV peak-systolic pressures of 40.7�16.1 mm Hg. In controls, the apical trabecular component EDV was 51.5�11.1 mL/m 2 (54.3�6.8% of the total RV EDV), ESV was 19.2�6.3 mL/m 2 (47.6�10.5% of RV ESV), and SV was 32.3�6.9 mL/m 2 (58.9�6.6% of RV SV), resulting in an EF of 63.1�7.7%. When considering all patients, the apical trabecular component took up the greatest part of the overload, having an EDV of 76.5�18.1 mL/m 2 , and an ESV of 31.6�12.8 mL/m 2 , reflecting an increase of 49 and 67% over controls, respectively ( P 〈 0.001). EF was 59.7�10.7%, and was maintained at control levels ( P =0.132). In controls, the outlet had considerable ejecting force, with an EF of 54.8�9.1%, whereas it was decreased in the patients with tetralogy (EF=28.5�11.9%). There was significant increase of ESV ( P 〈 0.001), but not of EDV, with EF decreased by 45% ( P 〈 0.001). The inlet was not significantly affected by overload. The surgical technique did not significantly affect any measured parameter for any component. Conclusions— In patients with tetralogy of Fallot, subsequent to surgical correction, the individual components of the RV respond in characteristic fashion to RV overload.
    Type of Medium: Online Resource
    ISSN: 1941-9651 , 1942-0080
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2008
    detail.hit.zdb_id: 2440475-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2017
    In:  Circulation: Cardiovascular Imaging Vol. 10, No. 3 ( 2017-03)
    In: Circulation: Cardiovascular Imaging, Ovid Technologies (Wolters Kluwer Health), Vol. 10, No. 3 ( 2017-03)
    Type of Medium: Online Resource
    ISSN: 1941-9651 , 1942-0080
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2017
    detail.hit.zdb_id: 2440475-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2017
    In:  Circulation: Cardiovascular Imaging Vol. 10, No. 5 ( 2017-05)
    In: Circulation: Cardiovascular Imaging, Ovid Technologies (Wolters Kluwer Health), Vol. 10, No. 5 ( 2017-05)
    Type of Medium: Online Resource
    ISSN: 1941-9651 , 1942-0080
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2017
    detail.hit.zdb_id: 2440475-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    In: Journal of the American Heart Association, Ovid Technologies (Wolters Kluwer Health), Vol. 11, No. 7 ( 2022-04-05)
    Abstract: Right ventricular outflow tract (RVOT) stenosis after repair of tetralogy of Fallot has been linked with favorable right ventricular remodeling but adverse outcomes. The aim of our study was to assess the hemodynamic impact and prognostic relevance of right ventricular pressure load in this population. Methods and Results A total of 296 patients with repaired tetralogy of Fallot (mean age, 17.8±7.9 years) were included in a prospective cardiovascular magnetic resonance multicenter study. Myocardial strain was quantified by feature tracking technique at study entry. Follow‐up, including the need for pulmonary valve replacement, was assessed. The combined end point consisted of ventricular tachycardia and cardiac death. A higher echocardiographic RVOT peak gradient was significantly associated with smaller right ventricular volumes and less pulmonary regurgitation, but lower biventricular longitudinal strain. During a follow‐up of 10.1 (0.1–12.9) years, the primary end point was reached in 19 of 296 patients (cardiac death, n=6; sustained ventricular tachycardia, n=2; and nonsustained ventricular tachycardia, n=11). A higher RVOT gradient was associated with the combined outcome (hazard ratio [HR], 1.03; 95% CI, 1.00–1.06; P =0.026), and a cutoff gradient of ≥25 mm Hg was predictive for cardiovascular events (HR, 3.69; 95% CI, 1.47–9.27; P =0.005). In patients with pulmonary regurgitation ≥25%, a mild residual RVOT gradient (15–30 mm Hg) was not associated with a lower risk for pulmonary valve replacement. Conclusions Higher RVOT gradients were associated with less pulmonary regurgitation and smaller right ventricular dimensions but were related to reduced biventricular strain and emerged as univariate predictors of adverse events. Mild residual pressure gradients did not protect from pulmonary valve replacement. These results may have implications for the indication for RVOT reintervention in this population.
    Type of Medium: Online Resource
    ISSN: 2047-9980
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2653953-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    In: Circulation, Ovid Technologies (Wolters Kluwer Health), Vol. 110, No. 2 ( 2004-07-13), p. 163-169
    Abstract: Background— Operator-independent isotropic 3D MRI may greatly simplify the assessment of complex morphology in congenital heart disease. We sought to evaluate the reliability of this new approach. Methods and Results— In 31 adolescent and adult patients (age, 6 to 42 years; median, 16 years) with congenital heart disease, cardiac morphology was determined with free-breathing (navigator-gated), isotropic, 3D steady-state free-precession (3D SSFP) MRI and independently evaluated by 2 observers. Cardiac diagnoses and multiple distance measurements were compared with conventional MR reference sequences (ie, spin-echo, cine gradient-echo, contrast-enhanced MR angiography) and with echocardiography/cine cardioangiography or surgery. Of the 31 patients, 24 had native congenital heart defects or residual defects after repair that warranted immediate treatment. None of these defects was missed by 3D SSFP. Novel diagnostic issues were discovered in 4 of 31 patients (coronary anomalies, n=3; left juxtaposition of the right atrial appendage in double-outlet right ventricle and transposition of the great arteries, 1). For sizes of valves and vessels, we found minor mean differences of −1.1 to 1.6 mm, with SD ranging from 1.2 to 2.9 mm, demonstrating overall good agreement with standard MRI (Bland-Altman analysis). Interobserver variability of 3D SSFP distance measures was low; mean differences ranged from −1.5 to 1.0 mm, and SD ranged from 0.8 to 2.5 mm. Scatter was lower for extracardiac than intracardiac measures. Conclusions— In adolescents and adults, isotropic 3D SSFP MRI allows reliable assessment of complex cardiac morphology. Distance measurements are accurate and reproducible. Thus, a single operator-independent acquisition may substitute for conventional 2D MRI sequences to accelerate and simplify MR scanning in congenital heart disease.
    Type of Medium: Online Resource
    ISSN: 0009-7322 , 1524-4539
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2004
    detail.hit.zdb_id: 1466401-X
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...