GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • IOP Publishing  (3)
  • Unknown  (3)
Material
Publisher
  • IOP Publishing  (3)
Language
  • Unknown  (3)
Years
Subjects(RVK)
  • 1
    In: Physics in Medicine & Biology, IOP Publishing, Vol. 67, No. 20 ( 2022-10-21), p. 205004-
    Abstract: Objective . To develop a simultaneous positron emission tomography-Optical (OPET) breast imaging dual-head PET subsystem, called DH-Mammo PET, for accurate, early diagnosis and efficacy assessment of breast cancer with high resolution and sensitivity. Approach . We developed a breast-dedicated PET based on LYSO crystal, silicon photomultiplier array and multi-voltage threshold sampling technique. It consists of two detector heads, each with a detection area of 216 mm × 145.5 mm. The distance between the detector heads is fixed at 120 mm. In order to extract coincidences and correct data, GPU-based software coincidence processing, random, scatter, normalization, gap-filling and attenuation corrections were applied in turn. The images were reconstructed using maximum likelihood expectation maximization with depth of interaction (DOI) modeling. The performance of DH-Mammo PET was evaluated referring to NEMA NU 4–2008, NU 2–2007 and Chinese industry recommended standard YY/T 1835–2022. Besides, several clinical patient images of DH-Mammo PET were compared with those of a whole-body PET/CT. Main results . The energy resolution was 14.5%, and time resolution was  〈  1.31 ns. Indicated by the 22 Na point source imaging, its spatial resolution was 2.60 mm (5.40 mm), 1.00 mm (1.04 mm), and 0.96 mm (0.93 mm) in the X , Y and Z directions, respectively, using the system response matrix with (without) DOI modeling. Indicated by the Derenzo phantom imaging, the spatial resolution was ∼3.0 mm, 〈 1.2 mm, and 〈 1.2 mm in the X , Y and Z directions. The system sensitivity was 6.87%, 4.89% and 3.37% with an energy window of 100–800, 250–750 and 350–650 keV, respectively. The scatter fraction was 26.43%, and the peak NECR was 162.6 kcps at 24.1 MBq for the modified rat-like phantom. As for the recovery coefficients, they ranged from 0.15 to 1.04 for rods between 1 and 5 mm obtained with a NEMA image quality phantom. The spill-over ratio for the air-filled and water-filled chamber was 0.05 and 0.11, respectively. DH-Mammo PET can provide more image details in clinical experiments and fulfil a fast scan with 60–120 s acquisition time. Significance . Good spatial resolution and high sensitivity of DH-Mammo PET would enable fast and accurate PET imaging of the breast. Besides, combining the DH-Mammo PET with the diffuse optical tomography would make full use of tumor metabolic imaging and tissue endogenous optical imaging, which would improve the accuracy of early clinical diagnosis of small lesions of breast cancers.
    Type of Medium: Online Resource
    ISSN: 0031-9155 , 1361-6560
    RVK:
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2022
    detail.hit.zdb_id: 1473501-5
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    IOP Publishing ; 2006
    In:  Modelling and Simulation in Materials Science and Engineering Vol. 14, No. 3 ( 2006-04-01), p. 331-349
    In: Modelling and Simulation in Materials Science and Engineering, IOP Publishing, Vol. 14, No. 3 ( 2006-04-01), p. 331-349
    Type of Medium: Online Resource
    ISSN: 0965-0393 , 1361-651X
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2006
    detail.hit.zdb_id: 2001737-6
    SSG: 11
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    IOP Publishing ; 2017
    In:  Journal of Physics: Condensed Matter Vol. 29, No. 37 ( 2017-09-20), p. 375201-
    In: Journal of Physics: Condensed Matter, IOP Publishing, Vol. 29, No. 37 ( 2017-09-20), p. 375201-
    Type of Medium: Online Resource
    ISSN: 0953-8984 , 1361-648X
    Language: Unknown
    Publisher: IOP Publishing
    Publication Date: 2017
    detail.hit.zdb_id: 1472968-4
    detail.hit.zdb_id: 228975-1
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...