GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Institute of Advanced Engineering and Science  (1)
  • Junaid Tahir, M.  (1)
  • Unknown  (1)
Material
Publisher
  • Institute of Advanced Engineering and Science  (1)
Person/Organisation
Language
  • Unknown  (1)
Years
  • 1
    Online Resource
    Online Resource
    Institute of Advanced Engineering and Science ; 2019
    In:  Indonesian Journal of Electrical Engineering and Computer Science Vol. 15, No. 1 ( 2019-07-01), p. 230-
    In: Indonesian Journal of Electrical Engineering and Computer Science, Institute of Advanced Engineering and Science, Vol. 15, No. 1 ( 2019-07-01), p. 230-
    Abstract: 〈 p class="IEEEAuthorAffiliation" 〉 The motive of contriving the proposed research was originated after recognizing some false alarm in measuring health parameters and practical issues in hospitals for example approachability and presence of patient at designated place for the evaluation of the health parameters like Blood pressure, sugar, body temperature, pulse and some other parameters.  The manual entry of the data into the systems have been become a critical problem. To vanquish this problem, a wearable gadget has been designed, so that a patient can carry it feasibly. Various approaches like Bayesian classifier has been applied to minimize the false alarm. Fuzzy logic, Kalman filtering, extended Kalman filtering, support vector machine, multi-layer perceptron, adaptive neuro fuzzy inference system and cuckoo search have been applied to eliminate the false alarm and give the best optimum solution. Results have proved that PSO worked betted as its convergence time is less than the others algorithms and produced best optimum value for the body vitals. Moreover, PSO has been applied to achieve the best optimal results and to increase the performance.  Monitoring of heart pulse rate and body temperature readings that were recorded in database were then tested and validated by comparing digital thermometer and digital inflator. PSO will converge and give the global best position of data by updating the velocity. Results proved that PSO produced better results by optimizing with better accuracy and precision and can be acknowledged as cost-effective solution. 〈 /p 〉
    Type of Medium: Online Resource
    ISSN: 2502-4760 , 2502-4752
    URL: Issue
    Language: Unknown
    Publisher: Institute of Advanced Engineering and Science
    Publication Date: 2019
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...