In:
The Journal of the Acoustical Society of America, Acoustical Society of America (ASA), Vol. 104, No. 6 ( 1998-12-01), p. 3446-3455
Abstract:
A pair of air-coupled ultrasonic capacitance transducers with polished metal backplates have been used to image temperature and flow fields in gases using ultrasonic tomography. Using a filtered back-projection algorithm and a difference technique, cross-sectional images of spatially variant changes in ultrasonic attenuation and slowness caused by the presence of temperature and flow fields were reconstructed. Temperature fields were produced in air by a commercial soldering iron, and the subsequent images of slowness variations used to reconstruct the air temperature at various heights above the iron. When compared to measurements made with a thermocouple, the tomographically reconstructed temperatures were found to be accurate to within 5%. The technique was also able to resolve multiple heat sources within the scan area. Attenuation and velocity images were likewise produced for flow fields created by an air-jet from a 1-mm-diam nozzle, at both 90 and 45 degrees to the scanning plane. The fact that temperature and flow fields can be measured in a gas without the need to insert any measuring devices into the image region is an advantage that may have many useful applications.
Type of Medium:
Online Resource
ISSN:
0001-4966
,
1520-8524
Language:
English
Publisher:
Acoustical Society of America (ASA)
Publication Date:
1998
detail.hit.zdb_id:
1461063-2