GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1,511)
  • 1990-1994  (1,511)
  • 1991  (1,511)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 128-132 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Many drugs are recemic and therefore much effort has to be devoted towards the stereoselective synthesis of the most effective or less harmful component of a racemic mixture. High performance liquid chromatography will play an important role in the clinical analysis of racemic drugs in anticipation of regulations that are currently being discussed and are expected to be enforced by the end of this decade. In this review a number of methods for chiral resolution are outlined. These include the formation of diastereoisomers and the use of chiral stationary phases or chiral mobile phase additives.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 141-141 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 161-164 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Medium- and long-chain 3-hydroxymonocarboxylic acids represent intermediates in the β-oxidation of fatty acids: they accumulate in the plasma of patients with an inherited deficiency of long-chain 3-hydroxyacylcoenzyme A dehydrogenase. 3-Hydroxy acids with chain lengths varying from 6 to 16 were synthesized by a Reformatzky reaction. Capillary gas chromatography of the pertrimethylsilyl derivatives was performed on a CP-Sil 19 CB column, coupled to a quadrupole mass spectrometer in the electron impact mode. Calculation of the retention indices showed that the separation of the 3-hydroxy acids from the homologous straight-chain fatty acids may be troublesome, stressing the need for mass spectrometric identification.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 153-160 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A new method is described for the analysis of vitamin D and its metabolites utilizing thermospray (TSP) mass spectrometry as an on-line detector for high performance liquid chromatogrpahy. Ionization conditions were optimized for use with isocratic reversed phase chromatography. TSP mass spectrometry was employed in series with a UV absorbance detector to facilitate comparisons between the two methods of detection. Positive ion TSP mass spectra were recorded for vitamin D2, vitamin D3, 25-hydroxyvitamin D3 (25(OH)D3), 1,25-dihydroxyvitamin D3 (1,25(OH)2D3) and 24,25-dihydroxyvitamin D3 (24,25(OH)2D3). The spectra contained protonated molecular ions, ammonium adduct ions and fragment ions due to the loss of one or more molecules of water. A comparison of quantitative precision was made by determining UV absorbance and TSP standard curves for vitamin D3 using two different methods: (1) External standard method with post-column (post UV detector) addition of ammonium acetate. (2) As (1) but using the method of internal standards with a closely eluting internal standard (vitamin D2). In each case the quantitative precision (correlation coefficient) for UV absorbance detection was superior owing to intrinsic instability of the TSP ion beam. A stable isotopically labelled internal standard was employed in the development of an assay for 1,25(OH)2D3. The assay was used to quantify in vitro enzymic conversion of 25(OH)D3 to 1,25(OH)2D3 in guinea pig and sheep renal mitochondrial incubations. TSP LC/MS was also applied to analysis of an extract of human blood plasma in which D3 and each of its principal metabolites were identified in a single analysis.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 113-121 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Chromatography has played a pivotal role in the advances made during the last 30 years in our knowledge of inborn errors of metabolism. This review discusses the application of some of these techniques to the analysis of organic acids and acylcarnitines. The separation of organic acids needed a comprehensive approach that would permit all of the many organic acids present in urine or other complex mixtures to be extracted, analysed and identified in a single run. This required analytical methods of great resolving power, wide linear range and universal detectors such as gas chromatography (GC), or GC coupled with mass spectrometry. Sample preparation was another problem that has been tackled by a variety of approaches. Organic solvents have been employed widely for the extraction of organic acids from physiological fluids. Unfortunately, recoveries of the different organic acids by this method are sometimes less than quantitative and variable depending on the compound. Other methods, such as the use of DEAE-Sephadex columns, have the advantage of resulting in close to 100% recoveries, but are more tedious. Liquid partition chromatography on short silicic acid columns has also been recommended as a useful clean-up step prior to GC, permitting both the identification and quantitation of organic acids in urine, plasma or amniotic fluid. Although many derivatization procedures have been used to prepare organic acids for gas chromatography, the most common is trimethylsilylation. Oxo acids are usually reacted with one of several commonly used reagents to form oximes. GC analysis of organic acids was initially done using packed columns with methylsilicone-based, non-polar stationary phases. In recent years most laboratories have switched to the commercially available, bonded-phase capillary columns. Some authors have recommended the use of two columns of slightly differing polarities to improve the reliability of identification without mass spectrometry. Carnitine and acylcarnitines are substances whose measurement may yield useful diagnostic information about inborn errors and about the basic biochemical mechanisms of disease. While free carnitine is usually measured by a radioenzymatic assay, the separation of acylcarnitines requires paper chromatography or high performance liquid chromatography. The identification of various acylcarnitines following separation has been accomplished by mass spectrometric methods. Another technique relies on gas chromatographic identification of the acyl groups liberated following alkaline hydrolysis. Recently, liquid chromatography/mass spectrometry has also been utilized to separate and identify the various acylcarnitines present in urine and other biological samples.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 180-183 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A sensitive and selective, reasonably fast method for the determination of glucose content has been developed. A glucose oxidase immobilized column was coupled to a small-size anion exchange column/borate buffer chromatograph. The hydrogen peroxide produced in the enzyme reaction was detected directly by an amperometric detector using a platinum working electrode. The detection limit was 0.03 ppm (1.5 × 10-7 M, 3 pmol/injection). The linear dynamic range was three orders of magnitude at least. The system was stable and reproducible both in short-and long-term operation. The proposed method is suitable for analysis of complicated matrices of biological samples because of its good selectivity and sensitivity.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991) 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Biomedical Chromatography 5 (1991), S. 198-201 
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Plasma B-6 vitamer and plasma and urinary 4-pyridoxic acid concentrations of 21 young white women, 21-27 years, having radiomonitored pyridoxal 5′-phosphate and coenzyme stimulation of erythrocyte alanine amino-transferase activities indicative of adequate vitamin B-6 status were determined in an effort to establish normal ranges for plasma B-6 vitamers. B-6 vitamers and 4-pyridoxic acid were quantitated using reversed phase high performance liquid chromatography with fluorometric and ultraviolet detection. Pyridoxal phosphate values obtained by radioenzymatic and chromatographic, fluorometric and ultraviolet, assays were highly correlated as were pyridoxine phosphate values determined using both detectors. The B-6 vitamer and 4-pyridoxic acid values of these subjects should be of use in the establishment of normal ranges of these congeners in women.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: We have compared anion exchange chromatography on APS-Hypersil (4.6 × 100 mm) eluted with a phosphate gradient with reversed phase chromatography on ODS-Hypersil (4.6 × 100 mm) in the presence of either tetrabutylammonium (TBA) or triethylammonium (TEA) ions with a methanol gradient. The systems have been compared both for ease of operation and for their resolving power with standard mixtures and acid extracts of both normal red cells (RBC) and ischaemic tissues. The two chromatographic modes exhibited similar separating efficiencies for standard mixtures of nucleotides but retention times were most stable using reversed phase liquid chromatography (RPLC) with TEA. Anion exchange columns slowly lost ion exchange capacity but selectivity was unchanged. RPLC in the presence of TBA gave reproducibile capacity factors only when operated isocratically due to irreversible changes to the silica surface. For RBCs the RPLC with TEA and anion exchange sysems resolved 17 and 15 peaks, respectively, and for the ischaemic samples 22 and 14 peaks, respectively. However, nucleosides and bases were also resolved by the ODS column causing chromatographic crowding and uncertain peak identification.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...