GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (2)
  • Wiley-Blackwell  (2)
  • Journal of Magnetic Resonance Imaging  (2)
  • 4564
  • 1
    Publication Date: 2012-04-16
    Description: Purpose: To evaluate the feasibility of semiquantitative measurement of liver perfusion from analysis of ferucarbotran induced signal-dynamics in double-contrast liver MR-imaging (DC-MRI). Materials and Methods: In total 31 patients (21 men; 58 ± 10 years) including 18 patients with biopsy proven liver cirrhosis prospectively underwent clinically indicated DC-MRI at 1.5 Tesla (T) with dynamic T2*-weighted gradient-echo imaging after ferucarbotran bolus injection. Breathing artefacts in tissue and input time curves were reduced by Savitzky-Golay-filtering and semiquantitative perfusion maps were calculated using a model free approach. Hepatic blood flow index (HBFI) and splenic blood flow index (SBFI) were determined by normalization of arbitrary perfusion values to the perfusion of the erector spinae muscle resulting in a semiquantitative perfusion measure. Results: In 30 of 31 patients the evaluated protocol could successfully be applied. Mean HBF was 7.7 ± 2.46 (range, 4.6–12.8) and mean SBF was 13.20 ± 2.57 (range, 8.5–17.8). A significantly lower total HBF was seen in patients with cirrhotic livers as compared to patients with noncirrhotic livers ( P 〈 0.05). In contrast, similar SBF was observed in cirrhotic and noncirrhotic patients ( P = 0.11). Conclusion: Capturing the signal dynamics during bolus injection of ferucarbotran in DC-MRI of the liver allows for semiquantitative assessment of hepatic perfusion that may be helpful for a more precise characterisation of liver cirrhosis and focal liver lesions. J. Magn. Reson. Imaging 2012;. © 2012 Wiley Periodicals, Inc.
    Print ISSN: 1053-1807
    Electronic ISSN: 1522-2586
    Topics: Medicine
    Published by Wiley-Blackwell
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2014-12-02
    Description: Background : To quantitatively and qualitatively assess vastus medialis muscle atrophy in asymptomatic patients with anterior cruciate ligament reconstruction, using the nonoperated leg as control. Methods : Prospective Institutional Review Board approved study with written informed patient consent. Thirty-three asymptomatic patients (men, 21; women,12) with ACL-reconstruction underwent MR imaging of both legs (axial T1-weighted spin-echo and 3D spoiled dual gradient-echo sequences). Muscle volume and average fat-signal fraction (FSF) of the vastus medialis muscles were measured. Additionally, Goutallier classification was used to classify fatty muscle degeneration. Significant side differences were evaluated using the Wilcoxon test and, between volumes and FSF, using student t-tests with P -value 〈 0.05 and 〈 0.025, respectively. Results : The muscle volume was significantly smaller in the operated (mean ± SD, 430.6 ± 119.6 cm 3 ; range, 197.3 to 641.7 cm 3 ) than in the nonoperated leg (479.5 ± 124.8 cm 3 ; 261.4 to 658.9 cm 3 ) ( P  〈 0.001). Corresponding FSF was 6.3 ± 1.5% (3.9 to 9.2%) and 5.8 ± 0.9% (4.0 to 7.4%), respectively, with a nonsignificant ( P  〉 0.025) difference. The relative muscle-volume and FSF differences were −10.1 ± 8.6% (7.1 to −30.1%) and 10.9 ± 29.4% (39.7 to 40.1%). The qualitative assessment revealed no significant differences ( P  〉 0.1). Conclusion : A significant muscle volume loss of the vastus medialis muscle does exist in asymptomatic patients with ACL-reconstruction, but without fatty degeneration. J. Magn. Reson. Imaging 2014.
    Print ISSN: 1053-1807
    Electronic ISSN: 1522-2586
    Topics: Medicine
    Published by Wiley-Blackwell
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...