GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2015-03-25
    Description: We report on the growth and structural and morphologic characterization of stacked layers of self-assembled GeSn dots grown on Si (100) substrates by molecular beam epitaxy at low substrate temperature T = 350 °C. Samples consist of layers (from 1 up to 10) of Ge 0.96 Sn 0.04 self-assembled dots separated by Si spacer layers, 10 nm thick. Their structural analysis was performed based on transmission electron microscopy, atomic force microscopy, and Raman scattering. We found that up to 4 stacks of dots could be grown with good dot layer homogeneity, making the GeSn dots interesting candidates for optoelectronic device applications.
    Print ISSN: 0021-8979
    Electronic ISSN: 1089-7550
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2016-02-20
    Description: Metallic nanoantennas can be used to enhance the efficiency of optical device operation by re-distributing electromagnetic energy. Here, we investigate the effect of a random distribution of disc-shaped Al nanoantennas of different diameters deposited on Ge-on-Si PIN-photodetectors on the wavelength-dependent responsivity. We compare our experimental results to simulations and find that the largest responsivity enhancement is obtained for wavelengths that correspond to energies at or below the bandgap energy of Ge. We argue that this is the result of antenna-mediated scattering of light into waveguide modes within the Ge-on-Si PIN-photodetectors, which is effectively influenced by nanoantenna size, and we discuss a possible application of the concept for integrated biosensing.
    Print ISSN: 0003-6951
    Electronic ISSN: 1077-3118
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-10-14
    Description: Rationale: Myocardial infarction (MI) increases the wall stress in the viable myocardium and initiates early adaptive remodeling in the left ventricle to maintain cardiac output. Later remodeling processes include fibrotic reorganization that eventually leads to cardiac failure. Understanding the mechanisms that support cardiac function in the early phase post MI and identifying the processes that initiate transition to maladaptive remodeling are of major clinical interest. Objective: To characterize MI-induced changes in titin-based cardiac myocyte stiffness and to elucidate the role of titin in ventricular remodeling of remote myocardium in the early phase after MI. Methods and Results: Titin properties were analyzed in Langendorff-perfused mouse hearts after 20-minute ischemia/60-minute reperfusion (I/R), and mouse hearts that underwent ligature of the left anterior descending coronary artery for 3 or 10 days. Cardiac myocyte passive tension was significantly increased 1 hour after ischemia/reperfusion and 3 and 10 days after left anterior descending coronary artery ligature. The increased passive tension was caused by hypophosphorylation of the titin N2-B unique sequence and hyperphosphorylation of the PEVK (titin domain rich in proline, glutamate, valine, and lysine) region of titin. Blocking of interleukine-6 before left anterior descending coronary artery ligature restored titin-based myocyte tension after MI, suggesting that MI-induced titin stiffening is mediated by elevated levels of the cytokine interleukine-6. We further demonstrate that the early remodeling processes 3 days after MI involve accelerated titin turnover by the ubiquitin–proteasome system. Conclusions: We conclude that titin-based cardiac myocyte stiffening acutely after MI is partly mediated by interleukine-6 and is an important mechanism of remote myocardium to adapt to the increased mechanical demands after myocardial injury.
    Keywords: Ischemia, Myocardial Biology, Myocardial Infarction, Remodeling
    Print ISSN: 0009-7330
    Electronic ISSN: 1524-4571
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2014-06-12
    Description: The origin of the deep subgap states in amorphous indium gallium zinc oxide (a-IGZO), whether intrinsic to the amorphous structure or not, has serious implications for the development of p -type transparent amorphous oxide semiconductors. We report that the deep subgap feature in a-IGZO originates from local variations in the oxygen coordination and not from oxygen vacancies. This is shown by the positive correlation between oxygen composition and subgap intensity as observed with X-ray photoelectron spectroscopy. We also demonstrate that the subgap feature is not intrinsic to the amorphous phase because the deep subgap feature can be removed by low-temperature annealing in a reducing environment. Atomistic calculations of a-IGZO reveal that the subgap state originates from certain oxygen environments associated with the disorder. Specifically, the subgap states originate from oxygen environments with a lower coordination number and/or a larger metal-oxygen separation.
    Print ISSN: 0003-6951
    Electronic ISSN: 1077-3118
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2014-11-19
    Description: Background— Assessment of systemic right ventricular (RV) function in patients with hypoplastic left heart syndrome is important during long-term follow-up after Fontan repair. Traditional echocardiographic parameters to evaluate systolic ventricular function are affected by loading conditions. The only generally accepted load-independent parameter of systolic function, end systolic elastance ( E es ), requires invasive catheterization. Therefore, we sought to determine if parameters obtained by 2-dimensional speckle tracking (2DST) were affected by acute changes in preload and correlated with catheterization-derived indices of RV contractility in hypoplastic left heart syndrome patients after Fontan palliation. Methods and Results— Fifty-two patients with hypoplastic left heart syndrome (median age, 6.6; range 2.9–22.2 years) were prospectively enrolled to have echocardiography and conductance catheter studies performed simultaneously. We compared traditional echo, 2-dimensional speckle tracking and catheterization-derived parameters during different states of preload at baseline and during dobutamine infusion. Global longitudinal strain (S) showed a tendency to decrease with preload reduction, whereas global longitudinal strain rate (SR) did not change (S: –17.7±3.4% versus –16.9±3.8%, P =0.08; SR: –1.30±0.29 versus –1.34±0.34 s –1 , P =0.3). S did not change with dobutamine infusion (–17.7±3.4% versus –18.4±3.9%, P =0.24), whereas SR increased significantly (–1.30±0.29 versus –2.26±0.49 s –1 , P 〈0.001). RV E es correlated with SR ( r s = –0.47, P 〈0.001), but not with S ( r s =0.07, P =0.5) or other echocardiographic parameters. Conclusions— In contrast to S, SR was not affected by preload and correlated with E es of the systemic RV. SR may be a useful noninvasive surrogate of RV contractility and suitable for follow-up of patients with hypoplastic left heart syndrome after Fontan palliation.
    Keywords: Echocardiography, Other diagnostic testing, Pediatric and congenital heart disease, including cardiovascular surgery
    Print ISSN: 1941-9651
    Electronic ISSN: 1942-0080
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2015-04-09
    Description: A three-state magnetic memory was developed based on differences in the magnetic permeability of a soft ferromagnetic media, Metglas 2826MB (Fe 40 Ni 38 Mo 4 B 18 ). By heating bits of a 250 nm thick Metglas film with 70–100 mW of laser power, we were able to tune the local microstructure, and hence, the permeability. Ternary memory states were created by using lower laser power to enhance the initial permeability through localized atomic rearrangement and higher power to reduce the permeability through crystallization. The permeability of the bits was read by detecting variations in an external 32 Oe probe field within 10 μ m of the media via a magnetic tunnel junction read head. Compared to data based on remanent magnetization, these multi-permeability bits have enhanced insensitivity to unexpected field and temperature changes. We found that data was not corrupted after exposure to fields of 1 T or temperatures of 423 K, indicating the effectiveness of this multi-state approach for safely storing large amounts of data.
    Print ISSN: 0003-6951
    Electronic ISSN: 1077-3118
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2015-12-24
    Description: Background— Transvenous lead removal (TLR) has made significant progress with respect to innovation, efficacy, and safety. However, limited data exist regarding trends in use and adverse outcomes outside the centers of considerable experience for TLR. The aim of our study was to examine use patterns, frequency of adverse events, and influence of hospital volume on complications. Methods and Results— Using the Nationwide Inpatient Sample, we identified 91 890 TLR procedures. We investigated common complications including pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in-hospital deaths described with TLR, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. We specifically assessed in-hospital death (2.2%), hemorrhage requiring transfusion (2.6%), vascular complications (2.0%), pericardial complications (1.4%), open heart surgery (0.2%), and postoperative respiratory failure (2.4%). Independent predictors of complications were female sex and device infections. Hospital volume was not independently associated with higher complications. There was a significant rise in overall complication rates over the study period. Conclusions— The overall complication rate in patients undergoing TLR was higher than previously reported. Female sex and device infections are associated with higher complications. Hospital volume was not associated with higher complication rates. The number of adverse events in the literature likely underestimates the actual number of complications associated with TLR.
    Keywords: Arrhythmias, Catheter Ablation and Implantable Cardioverter-Defibrillator, Electrophysiology, Quality and Outcomes
    Electronic ISSN: 1524-4539
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2015-10-28
    Description: Background Patients with hypoplastic left heart syndrome after a Norwood operation show dilatation and reduced distensibility of the reconstructed proximal aorta. Cardiac magnetic resonance imaging (CMR) and angiographic examinations indicate that the native descending aorta (DAo) is also dilated, but this has not been studied in detail. Methods and Results Seventy-nine children with hypoplastic left heart syndrome in Fontan circulation (aged 6.3±3.2 years) and 18 control participants (aged 6.8±2.4 years) underwent 3.0-tesla CMR. Gradient-echo cine and phase-contrast imaging was applied to measure cross-sectional areas (CSAs), distensibility, pulse wave velocity, and the incremental elastic modulus of the thoracic aorta. CSA of the DAo in patients was also compared with published percentiles for aortic CSA. Patients had significantly larger CSA of the DAo at the level of pulmonary artery bifurcation (229.1±97.2 versus 175.7±24.3 mm/m 2 , P =0.04) and the diaphragm (196.2±66.0 versus 142.6±16.7 mm/m 2 , P 〈0.01). In 41 patients (52%), CSA of the DAo was 〉95th percentile level for control participants, and the incremental elastic modulus of the aortic arch and the DAo was higher than in patients with normal CSAs (arch: 90.1±64.3 versus 45.6±38.9 m/s; DAo: 86.3±53.7 versus 47.1±47.6 m/s; P 〈0.01). Incremental elastic modulus of the aortic arch and the DAo correlated with the CSA of the DAo (arch: r =0.5; DAo: r =0.49; P 〈0.01). Conclusions Children with hypoplastic left heart syndrome frequently show dilatation of their DAo associated with increased stiffness of the aortic arch. Higher aortic impedance increases the afterload of the systemic circulation and likely contributes to the burden of the systemic right ventricle.
    Electronic ISSN: 2047-9980
    Topics: Medicine
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2015-12-29
    Description: We report on the fabrication and structural characterization of epitaxially grown ultra-thin layers of Sn on Ge virtual substrates (Si buffer layer overgrown by a 50 nm thick Ge epilayer followed by an annealing step). Samples with 1 to 5 monolayers of Sn on Ge virtual substrates were grown using solid source molecular beam epitaxy and characterized by atomic force microscopy. We determined the critical thickness at which the transition from two-dimensional to three-dimensional growth occurs. This transition is due to the large lattice mismatch between Ge and Sn (≈14.7%). By depositing Ge on top of Sn layers, which have thicknesses at or just below the critical thickness, we were able to fabricate ultra-narrow GeSn multi-quantum-well structures that are fully embedded in Ge. We report results on samples with one and ten GeSn wells separated by 5 and 10 nm thick Ge spacer layers that were characterized by high resolution transmission electron microscopy and X-ray diffraction. We discuss the structure and material intermixing observed in the samples.
    Print ISSN: 0003-6951
    Electronic ISSN: 1077-3118
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2016-06-15
    Description: The group-IV semiconductor alloy Ge 1− x − y Si x Sn y has recently attracted great interest due to its prospective potential for use in optoelectronics, electronics, and photovoltaics. Here, we investigate molecular beam epitaxy grown Ge 1− x − y Si x Sn y alloys lattice-matched to Ge with large Si and Sn concentrations of up to 42% and 10%, respectively. The samples were characterized in detail by Rutherford backscattering/channeling spectroscopy for composition and crystal quality, x-ray diffraction for strain determination, and photoluminescence spectroscopy for the assessment of band-gap energies. Moreover, the experimentally extracted material parameters were used to determine the SiSn bowing and to make predictions about the optical transition energy.
    Print ISSN: 0003-6951
    Electronic ISSN: 1077-3118
    Topics: Physics
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...