GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gerriets, Tibo  (1)
  • 1
    In: Stroke, Ovid Technologies (Wolters Kluwer Health), Vol. 37, No. 5 ( 2006-05), p. 1301-1306
    Abstract: Background and Purpose— Ultrasound-accelerated thrombolysis is a promising approach toward acute stroke treatment. In previous in vitro studies, we demonstrated enhanced thrombus destruction induced by 20-kHz ultrasound. However, little is known about biological interactions of low-frequency ultrasound with brain tissue. The aim of this in vivo MRI study was to assess safety aspects of transcranial low-frequency ultrasound in rats. Methods— The cranium of 33 male Wistar rats was sonificated for 20 minutes (20-kHz continuous wave). Power output was varied between 0 and 2.6 W/cm 2 . Tympanal and rectal temperature was monitored. Diffusion-weighted imaging and T2-weighted imaging was performed before and 4 hours, 24 hours, and 5 days after sonification. Apparent diffusion coefficients (ADCs) and T2 relaxation time (T2-RT) were measured in regions of interest in the cortex and the basal ganglia. The animals were euthanized for histological evaluation thereafter. Results— Tympanal temperature increased significantly during insonation with 1.1 and 2.6 W/cm 2 . ADCs decreased significantly at 0.5 and 1.1 W/cm 2 , indicating cytotoxic edema. T2-RT increased significantly in the 0.5 and 1.1 W/cm 2 group, consistent with vasogenic edema. No changes were detectable in the low-power output group (0.2 W/cm 2 ). After sonification with 2.6 W/cm 2 , a significant loss of neurons could be detected on histopathology. Furthermore, 3 animals developed circumscript cortical lesions that could be identified as parenchymal necrosis. Conclusion— Low-frequency ultrasound caused vasogenic and cytotoxic brain edema and intracerebral necrosis in a dose-dependent fashion. This study indicates therapeutic low-frequency ultrasound as being potentially harmful and underlines the necessity of careful evaluation in further animal models.
    Type of Medium: Online Resource
    ISSN: 0039-2499 , 1524-4628
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2006
    detail.hit.zdb_id: 1467823-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...